the United StatesBJC S400series
High alkalinity in industrial processespHDetection electrode
BJC S400 online high alkalinity pH electrode from the United StatesSpecially designed for harsh industrial processes with high alkalinity onlinepHTesting, it has a sturdy structure, adopts a dual stage reference electrode design, and has strong pollution resistance. The electrode has its own thread, and the installation method is flexible; The electrode body material is corrosion-resistantRyton(PPS)The reference membrane is porousTeflonOr ceramics. Users can choose to have a temperature probe or a glass head protective coverpHElectrode, to avoid breaking the glass film.
BJC S400 online high alkalinity pH electrode from the United StatesCommon models include:
S400-RT430-A10FF |
standard configuration3/4Inch thread |
S400-RT430-M30FF |
Standard strap9Rice thick cable |
S400-RT43D-E10FF |
beltPt100warm supplementation |
S400-RT43H-E10FF |
beltPt1000warm supplementation |
S400-RT43H-E10FF |
beltPt1000warm supplementation,HT-4Thick film |
S400-RT43D-E30FF |
beltPt100Warm compensation and proximity10Mi's cable |
Technical Specifications:
pHrange0 - 14 pH
ORPRange: ±5000 mV
Temperature range:0 - 105℃
Voltage resistance:150 psig at 100℃
Reference electrode:Ag/AgCl
Liquid connection material:Ryton®, Teflon®,glass
Standard cable length:10Foot low noise cable
Application scenarios:
Online water and sewage detection
Installation method:
Immersion and pipeline installation
Maximum flow rate:
per second3rice
Output impedance:
< 250 MΩat 25℃
Liquid connection material:Ryton®, Teflon®,glass
Reference diaphragm:Coaxial ringTeflonDiaphragm, pollution resistant, large surface area, adopting a dual stage design, greatly improving the anti-interference ability of the reference electrode
S400Series electrode selection table
Order number composition
S4 |
1 |
2 |
- |
3 |
4 |
5 |
6 |
7 |
- |
8 |
9 |
10 |
11 |
12 |
position |
Instructions |
1-2 |
Appearance structure |
00Standard insertion type, equipped with glass head protective baffle,3/4' NPTthread,Flat head cannot be selected, diaphragm can only be selectedT |
|
05Standard insertion type, equipped with glass head protective baffle,1' NPTthread,Flat head cannot be selected, diaphragm can only be selectedT |
|
10Standard insertion type, without protective shield,3/4' NPTthread |
|
15Standard insertion type, without protective shield,1' NPTthread |
|
20insertion depth2.6',Equipped with glass head protective baffle,3/4' NPTthread,Flat head cannot be selected, diaphragm can only be selectedT |
|
25insertion depth2.6',Equipped with glass head protective baffle,1' NPTthread,Flat head cannot be selected, diaphragm can only be selectedT |
|
30 insertion depth2.6',Without protective barriers,3/4' NPTthread |
|
35 insertion depth2.6',Without protective barriers,1' NPTthread |
|
77Valve installation, equipped with twoORing and glass head protective baffle, flat head cannot be selected, diaphragm can only be selectedR |
|
3 |
Material of electrode body |
R Ryton |
|
GgroundingRyton |
|
4 |
Type of liquid connected diaphragm |
TcoaxialTeflondiaphragm |
|
RCoaxial concave shapeTeflondiaphragm |
|
5-6 |
Glass sensor head |
33 pH, HT-3Thin film, hemispherical shape |
|
43 pH, HT-4Thin film, spherical, suitable for testingpH>13, as well as durabilityHFcorrosion |
|
PB ORPThe white gold ring |
|
17 pH, regular type, flat head |
|
7 |
temperature probe |
0Excluding temperature probe |
|
1 3KΩ |
|
D Pt 100 |
|
H Pt 1000 |
|
8 |
Cable type |
A 3 mmLow noise coaxial cable, no temperature signal |
|
M 5 mmLow noise coaxial cable, no temperature signal |
|
EShielded cable, containing temperature signal |
|
NShielded cable, including temperature signal and grounding wire |
|
9-10 |
cable length |
10 10foot |
|
XXexceed10Feet, please indicate |
|
11-12 |
cable joint |
BC BNCjoint |
|
FB BNCAnd solder joints |
|
FFSoldering tin head |