E-mail
31775247@qq.com
-
Phone
13911991473
-
Address
Room 403, Building 15, No. 109 Jinghai 3rd Road, Daxing District, Beijing, China
Beijing Qinye Zhiyuan Technology Co., Ltd
31775247@qq.com
13911991473
Room 403, Building 15, No. 109 Jinghai 3rd Road, Daxing District, Beijing, China
Dust concentration detector for rapid detection of occupational health particulate matter concentrationLD-8The Type Dust Concentration Detector is a rapid dust detector suitable for occupational health dust concentration detection. The instrument adopts the principle of light scattering and is equipped with a calibrated optical stability self calibration device, which can eliminate the influence of temperature and humidity drift and achieve rapid determination of the concentration of particles of different sizes in the air.Dust concentration detector for rapid detection of occupational health particulate matter concentrationThis instrument is suitable for rapid detection of dust concentration in the ambient air by comprehensive administrative law enforcement personnel in occupational health and ecological environment protection. It can also be used in public places (hotels, shopping malls, restaurants, office buildings and other places with high traffic volume), third-party testing institutions, university research institutes, shipbuilding, aviation, precision semiconductor manufacturing, grain processing, aluminum powder polishing, petroleum and petrochemical industries, etc.
JJG846-2015Measurement and Verification Regulations for Dust Concentration Measuring Instruments;
HJ653-2021《Environmental air particulate matter(PM10andPM2.5)Technical requirements and testing methods for continuous automatic monitoring system》;
GBZ2-2002Occupational Exposure Limits for Hazardous Factors in the Workplace;
GB/T18204.2-2014Methods for Health Inspection in Public Places2Part: Chemical Pollutants ";
GB/T18204.5-2013Methods for Health Inspection in Public Places5Part: Central Air Conditioning and Ventilation System
1.Measurement concentration range:0.001~1000mg/m³
2.Detection sensitivity:0.001 mg/m³
3.Measurement time:The standard is1minute,1secondto9999secondCan be set arbitrarily
4.Relative measurement error: For calibrated particles, the relative measurement error is less than10%;
5.Repetitive error: ≤2%
※6.Storage and Data Interface: Storage15000Group data,USBandRS232interface
7.Operating temperature:-10~40 ℃
8.Working hours: Powered by lithium batteries, continuous operation10hours or more
9.Overall dimensions:160mm×130mm×90mm
10.Weight:1.0kg