S490Dual clamp multifunctional grounding resistance tester
S490Dual clamp multifunctional grounding resistance testerAlso known as Double Clamp Grounding Resistance Tester or Double Clamp Grounding Resistance Tester, it consists of a main unit, current clamp (Double Clamp), data software, testing line, auxiliary grounding rod, communication line, etc. The main engine is designed in a toolbox style, using polypropylene plastic as raw material and adding new composite fillers for one-time injection molding. It has low density, strength, stiffness, hardness, wear resistance, heat resistance, and excellent insulation performance. Its box can withstand a pressure of about 200kg, ensuring high precision, stability, and reliability in various environmental tests. The host has a large LCD display with backlight and bar chart indication, which is clear at a glance. At the same time, it can store 2000 sets of data, and historical data reading, viewing, saving, reporting, printing and other functions can be achieved through data software.
One Technical Specifications
Function |
Measurement of grounding resistance, soil resistivity, DC resistance, conduction resistance, equipotential bonding resistance, grounding voltage, AC current, and leakage current |
Power supply |
11.1V DC, 2600mAh rechargeable lithium battery |
Backlight |
Controllable backlight, suitable for use in dark fields |
measurement method |
Precision four wire, three wire method measurement, simple two wire, selection method, double clamp method measurement of grounding resistance |
measurement method |
Two three four wire method measurement: pole changing method, short circuit measurement current 20mA Max Selection method measurement: pole changing method, short circuit measurement current 20mA Max Double clamp method: non-contact mutual inductance measurement method, testing current 1mA Max Soil resistivity: Quadrupole method (Wenner method) DC resistance: pole changing method AC current: average rectification (clamp) Ground voltage: average rectification (between P (S) - ES interface) |
Range |
Measurement of grounding resistance (Re) and DC resistance using the two three four wire method: 0.050Ω to 30000Ω |
Selection method for measuring grounding resistance (Re): 0.05 Ω~3000 Ω | |
Double clamp method for measuring grounding resistance (Re): 0.01 Ω~200 Ω | |
Soil resistivity (ρ): 0.31 Ω m~9000k Ω m | |
Grounding voltage (50Hz/60Hz): AC 0.0V~100.0V | |
AC current (50Hz/60Hz): AC 0.00mA~500.0A | |
resolution |
Measurement of grounding resistance (Re) and DC resistance using the two three four wire method: 0.001Ω (0.050Ω to 29.999Ω) 0.01Ω (30.00Ω to 299.99Ω) 0.1Ω (300.0Ω to 2999.9Ω) 1Ω (3000Ω to 30000Ω) |
|
Selection method for measuring grounding resistance (Re): 0.01Ω (0.05Ω to 29.99Ω) 0.1Ω (30.0Ω to 299.9Ω) 1Ω (300Ω to 3000Ω) | |
|
Double clamp method for measuring grounding resistance (Re): 0.01Ω (0.01Ω to 0.99Ω) 0.1Ω (1.0Ω to 29.9Ω) 1Ω (30Ω to 200Ω) | |
|
Soil resistivity (ρ): 0.01Ωm(0.31Ωm~99.99Ωm) 0.1Ωm(100.0Ωm~999.9Ωm) 1Ωm(1000Ωm~9999Ωm) 10Ωm(10.00kΩm ~99.99kΩm) 100Ωm(100.0kΩm~999.9kΩm) 1kΩm(1000kΩm~9000kΩm) | |
Grounding voltage (50Hz/60Hz): 0.1V | |
AC current (50Hz/60Hz): 0.01mA | |
|
Accuracy Accuracy |
Measurement of grounding resistance (Re) and DC resistance (R -) using the two three four wire method: ±10%rdg±50dgt (0.050Ω~0.500Ω) ±2%rdg±0.05Ω (0.500Ω~29.999Ω) ±2%rdg±3dgt (30.00Ω~299.99Ω) ±2%rdg±3dgt (300.0Ω~2999.9Ω) ±4%rdg±3dgt (3.000kΩ~30.00kΩ) Note: 1. The additional error at rC max or rP max is ≤± 5% rdg ± 5dgt. (rC max:4kΩ+100R<50kΩ, rP max:4kΩ+100R<50kΩ) 2. The additional error under 5V interference voltage is ≤± 5% rdg ± 5dgt. |
|
Selection method for measuring grounding resistance (Re): ±2%rdg±10dgt(0.05Ω~0.50Ω) ±2%rdg±5dgt(0.50Ω~29.99Ω) ±2%rdg±3dgt(30.0Ω~299.9Ω) ±2%rdg±3dgt (300Ω~3000Ω) | |
|
Double clamp method for measuring grounding resistance (Re): ±10%rdg±5dgt(0.01Ω~100Ω) ±20%rdg±5dgt(101Ω~200Ω) | |
|
Soil resistivity (ρ): determined by the measurement accuracy of R (ρ=2πaR a:1 m~100m;π=3.14) | |
Grounding voltage (50Hz/60Hz): ± 2% rdg ± 3dgt | |
AC current (50Hz/60Hz): ± 2% rdg ± 3dgt | |
Test voltage waveform |
sine wave |
test frequency |
128Hz/111Hz/105Hz/94Hz (automatic frequency selection) |
Short circuit test current |
AC 20mA max |
Open circuit test voltage |
AC 40V max |
Range of electrode spacing |
1m~100m |
display mode |
6-digit ultra large LCD display with backlight |
Measurement indication |
LED flashing indication during measurement, LCD countdown display |
LCD size |
128mm×75mm |
LCD display domain |
124mm×67mm |
Device dimensions |
Instrument length, width, and height: approximately 320mm × 275mm × 145mm Current clamp length, width, and height: approximately 220mm × 100mm × 27mm |
Package dimensions |
Outer packaging length, width, and height: approximately 400mm × 245mm × 335mm |
Test line |
Red 15m, black 15m, yellow 10m, green 10m each |
Simple testing line |
2 pieces: 1 red 1.6m, 1 black 1.6m each |
Auxiliary grounding rod |
4 pieces: 10mm x 200mm in diameter |
Current clamp |
2: CT1 pliers with red and black plugs, CT2 pliers with blue and black plugs, 1 each |
Current clamp diameter |
φ70mm |
Current clamp lead |
2m in length |
measure time |
AC current: approximately 2 times per second Ground voltage: about 2 times/second Grounding resistance: about 7 seconds/time |
number of measurements |
More than 5000 times (short circuit test, test once, stop for 30 seconds and then test again) |
line voltage |
Measurement below AC 100V |
communication interface |
Equipped with RS232 interface, data storage can be uploaded to the computer through software |
Communication line |
1 USB to 232 communication cable |
data retention |
When holding data, the "HOLD" symbol indicates |
data storage |
2000 sets, "MEM" storage indicator, displaying the "FULL" symbol to indicate that the storage is full |
data lookup |
When consulting data, the "READ" symbol indicates |
Overflow display |
The "OL" symbol indicates overflow of over range |
Current clamp low current indication |
When using the selection method or the double clamp method for measurement, if the current signal received by the CT2 clamp is below 0.5mA, it will display“ |
Interference testing |
Automatically identify interference signals, with interference voltage above 5V indicated by the "Noise" symbol |
Auxiliary grounding test |
Equipped with auxiliary grounding resistance value testing function, 0.00k Ω~30.00k Ω (100R+rC<50k Ω, 100R+rP<50k Ω) |
alarm function |
When the measured value exceeds the alarm set value, an alarm prompt of "beep beep beep beep beep" will appear |
battery voltage |
When the battery voltage is insufficient, the low battery voltage symbol is displayed, reminding that the battery needs to be charged. |
Auto Shutdown |
Automatically shut down after 15 minutes of startup |
Power consumption |
Backlight: 25mA Max (separate backlight power consumption) Standby: 25mA Max (backlight off after power on) Measurement: 150mA Max (backlight off) |
Quality |
Host: 2.66kg (including battery) Total weight: 7.87kg (including test wire, grounding pin, packaging) |
hold-all |
Toolbox design, capable of bearing 200kg |
Working temperature and humidity |
-10℃~40℃; Below 80% RH |
Storage temperature and humidity |
-20℃~60℃; Below 70% RH |
overload protection |
Measure grounding resistance: AC 280V/3 seconds between ports C (H) - E and P (S) - ES |
insulation resistance |
20M Ω or above (500V between circuit and casing) |
Voltage resistance |
AC 3700V/rms (between circuit and casing) |
electromagnetic properties |
IEC61326(EMC) |
Suitable for safety regulations |
IEC61010-1 (CAT III 300V, CAT IV 150V, Pollution Level 2); IEC61010-031; IEC61557-1 (Grounding Resistance); IEC61557-5 (soil resistivity); JJG 366-2004 (Grounding Resistance Meter); JJG 1054-2009 (clamp type grounding resistance meter). |