The S490 dual clamp multifunctional grounding resistance tester is designed and manufactured in accordance with the new lightning protection grounding resistance detection standard, specifically for on-site measurement of grounding resistance, soil resistivity, grounding voltage, grounding wire leakage current, AC current, and DC resistance

Product Details

S490Dual clamp multifunctional grounding resistance tester

S490Dual clamp multifunctional grounding resistance testerAlso known as Double Clamp Grounding Resistance Tester or Double Clamp Grounding Resistance Tester, it consists of a main unit, current clamp (Double Clamp), data software, testing line, auxiliary grounding rod, communication line, etc. The main engine is designed in a toolbox style, using polypropylene plastic as raw material and adding new composite fillers for one-time injection molding. It has low density, strength, stiffness, hardness, wear resistance, heat resistance, and excellent insulation performance. Its box can withstand a pressure of about 200kg, ensuring high precision, stability, and reliability in various environmental tests. The host has a large LCD display with backlight and bar chart indication, which is clear at a glance. At the same time, it can store 2000 sets of data, and historical data reading, viewing, saving, reporting, printing and other functions can be achieved through data software.

One Technical Specifications

Function

Measurement of grounding resistance, soil resistivity, DC resistance, conduction resistance, equipotential bonding resistance, grounding voltage, AC current, and leakage current

Power supply

11.1V DC, 2600mAh rechargeable lithium battery

Backlight

Controllable backlight, suitable for use in dark fields

measurement method

Precision four wire, three wire method measurement, simple two wire, selection method, double clamp method measurement of grounding resistance

measurement method

Two three four wire method measurement: pole changing method, short circuit measurement current 20mA Max

Selection method measurement: pole changing method, short circuit measurement current 20mA Max

Double clamp method: non-contact mutual inductance measurement method, testing current 1mA Max

Soil resistivity: Quadrupole method (Wenner method)

DC resistance: pole changing method

AC current: average rectification (clamp)

Ground voltage: average rectification (between P (S) - ES interface)

Range

Measurement of grounding resistance (Re) and DC resistance using the two three four wire method:

0.050Ω to 30000Ω

Selection method for measuring grounding resistance (Re): 0.05 Ω~3000 Ω

Double clamp method for measuring grounding resistance (Re): 0.01 Ω~200 Ω

Soil resistivity (ρ): 0.31 Ω m~9000k Ω m

Grounding voltage (50Hz/60Hz): AC 0.0V~100.0V

AC current (50Hz/60Hz): AC 0.00mA~500.0A

resolution

Measurement of grounding resistance (Re) and DC resistance using the two three four wire method:

0.001Ω (0.050Ω to 29.999Ω)

0.01Ω (30.00Ω to 299.99Ω)

0.1Ω (300.0Ω to 2999.9Ω)

1Ω (3000Ω to 30000Ω)

Selection method for measuring grounding resistance (Re):

0.01Ω (0.05Ω to 29.99Ω)

0.1Ω (30.0Ω to 299.9Ω)

1Ω (300Ω to 3000Ω)

Double clamp method for measuring grounding resistance (Re):

0.01Ω (0.01Ω to 0.99Ω)

0.1Ω (1.0Ω to 29.9Ω)

1Ω (30Ω to 200Ω)

Soil resistivity (ρ):

0.01Ωm(0.31Ωm~99.99Ωm)

0.1Ωm(100.0Ωm~999.9Ωm)

1Ωm(1000Ωm~9999Ωm)

10Ωm(10.00kΩm ~99.99kΩm)

100Ωm(100.0kΩm~999.9kΩm)

1kΩm(1000kΩm~9000kΩm)

Grounding voltage (50Hz/60Hz): 0.1V

AC current (50Hz/60Hz): 0.01mA


Accuracy








Accuracy

Measurement of grounding resistance (Re) and DC resistance (R -) using the two three four wire method:

±10%rdg±50dgt (0.050Ω~0.500Ω)

±2%rdg±0.05Ω (0.500Ω~29.999Ω)

±2%rdg±3dgt (30.00Ω~299.99Ω)

±2%rdg±3dgt (300.0Ω~2999.9Ω)

±4%rdg±3dgt (3.000kΩ~30.00kΩ)

Note: 1. The additional error at rC max or rP max is ≤± 5% rdg ± 5dgt. (rC max:4kΩ+100R<50kΩ, rP max:4kΩ+100R<50kΩ)

2. The additional error under 5V interference voltage is ≤± 5% rdg ± 5dgt.

Selection method for measuring grounding resistance (Re):

±2%rdg±10dgt(0.05Ω~0.50Ω)

±2%rdg±5dgt(0.50Ω~29.99Ω)

±2%rdg±3dgt(30.0Ω~299.9Ω)

±2%rdg±3dgt (300Ω~3000Ω)

Double clamp method for measuring grounding resistance (Re):

±10%rdg±5dgt(0.01Ω~100Ω)

±20%rdg±5dgt(101Ω~200Ω)

Soil resistivity (ρ): determined by the measurement accuracy of R

(ρ=2πaR a:1 m~100m;π=3.14)

Grounding voltage (50Hz/60Hz): ± 2% rdg ± 3dgt

AC current (50Hz/60Hz): ± 2% rdg ± 3dgt

Test voltage waveform

sine wave

test frequency

128Hz/111Hz/105Hz/94Hz (automatic frequency selection)

Short circuit test current

AC 20mA max

Open circuit test voltage

AC 40V max

Range of electrode spacing

1m~100m

display mode

6-digit ultra large LCD display with backlight

Measurement indication

LED flashing indication during measurement, LCD countdown display

LCD size

128mm×75mm

LCD display domain

124mm×67mm

Device dimensions

Instrument length, width, and height: approximately 320mm × 275mm × 145mm

Current clamp length, width, and height: approximately 220mm × 100mm × 27mm

Package dimensions

Outer packaging length, width, and height: approximately 400mm × 245mm × 335mm

Test line

Red 15m, black 15m, yellow 10m, green 10m each

Simple testing line

2 pieces: 1 red 1.6m, 1 black 1.6m each

Auxiliary grounding rod

4 pieces: 10mm x 200mm in diameter

Current clamp

2: CT1 pliers with red and black plugs, CT2 pliers with blue and black plugs, 1 each

Current clamp diameter

φ70mm

Current clamp lead

2m in length

measure time

AC current: approximately 2 times per second

Ground voltage: about 2 times/second

Grounding resistance: about 7 seconds/time

number of measurements

More than 5000 times (short circuit test, test once, stop for 30 seconds and then test again)

line voltage

Measurement below AC 100V

communication interface

Equipped with RS232 interface, data storage can be uploaded to the computer through software

Communication line

1 USB to 232 communication cable

data retention

When holding data, the "HOLD" symbol indicates

data storage

2000 sets, "MEM" storage indicator, displaying the "FULL" symbol to indicate that the storage is full

data lookup

When consulting data, the "READ" symbol indicates

Overflow display

The "OL" symbol indicates overflow of over range

Current clamp low current indication

When using the selection method or the double clamp method for measurement, if the current signal received by the CT2 clamp is below 0.5mA, it will display“”Symbol, at this time, the direction of the CT2 current clamp should be checked

Interference testing

Automatically identify interference signals, with interference voltage above 5V indicated by the "Noise" symbol

Auxiliary grounding test

Equipped with auxiliary grounding resistance value testing function, 0.00k Ω~30.00k Ω (100R+rC<50k Ω, 100R+rP<50k Ω)

alarm function

When the measured value exceeds the alarm set value, an alarm prompt of "beep beep beep beep beep" will appear

battery voltage

When the battery voltage is insufficient, the low battery voltage symbol is displayed, reminding that the battery needs to be charged.

Auto Shutdown

Automatically shut down after 15 minutes of startup

Power consumption

Backlight: 25mA Max (separate backlight power consumption)

Standby: 25mA Max (backlight off after power on)

Measurement: 150mA Max (backlight off)

Quality

Host: 2.66kg (including battery)

Total weight: 7.87kg (including test wire, grounding pin, packaging)

hold-all

Toolbox design, capable of bearing 200kg

Working temperature and humidity

-10℃~40℃; Below 80% RH

Storage temperature and humidity

-20℃~60℃; Below 70% RH

overload protection

Measure grounding resistance: AC 280V/3 seconds between ports C (H) - E and P (S) - ES

insulation resistance

20M Ω or above (500V between circuit and casing)

Voltage resistance

AC 3700V/rms (between circuit and casing)

electromagnetic properties

IEC61326(EMC)

Suitable for safety regulations

IEC61010-1 (CAT III 300V, CAT IV 150V, Pollution Level 2);

IEC61010-031; IEC61557-1 (Grounding Resistance);

IEC61557-5 (soil resistivity); JJG 366-2004 (Grounding Resistance Meter);