Dual channel laboratory pH/conductivity meterfunctional characteristics
Calibration from 1 to 3 points, automatically identifying USA/NIST standard buffer solutions.
Automatic electrode diagnosis helps users determine whether to replace the pH electrode.
Automatic temperature compensation ensures accurate measurement across the entire range.
Automatic endpoint locking, retaining stable readings for easy browsing and recording.
The settings menu allows customization of pH buffer groups, number of calibration points, temperature units, etc.
Reset function, automatically restore the instrument to factory default settings.
Dual channel laboratory pH/conductivity meter
Functional characteristics of EC unit
Calibration from 1 to 3 points, automatic identification of conductivity standard solution.
• Optional electrode constant, temperature compensation coefficient, TDS conversion coefficient.
Automatic temperature compensation, correcting conductivity measurements and converting readings to reference temperature.
Automatic endpoint locking, retaining stable readings for easy browsing and recording.
The settings menu allows customization of the number of calibration points, temperature units, etc.
Reset function, automatically restore the instrument to factory default settings.
parameter |
PHunit |
ECunit |
|
PH |
measurement range |
-1.00~15.00pH |
— |
display resolution |
0.01pH |
— |
|
measurement accuracy |
±0.01pH |
— |
|
calibration point |
From 1 to 3 o'clock |
— |
|
PH buffering option |
USA (pH4.01/7.00/10.01), NIST (pH4.01/6.86/9.18) |
— |
|
mV |
measurement range |
±1999mV |
— |
display resolution |
1mV |
— |
|
measurement accuracy |
±1mV |
— |
|
conductivity |
measurement range |
— |
0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm |
display resolution |
— |
0.001, 0.01, 0.1, 1 |
|
measurement accuracy |
— |
±1% F.S. |
|
calibration point |
— |
1-3 o'clock |
|
Use calibration solution |
— |
10µS, 84µS, 1413µS, 12.88mS, 111.8mS |
|
TDS |
measurement range |
— |
0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt |
display resolution |
— |
0.01, 0.1, 1 |
|
measurement accuracy |
— |
±1% F.S. |
|
TDS conversion coefficient |
— |
0.1 to 1.0 (default 0.5) |
|
temperature |
measurement range |
0 ~105°C/32~221°F |
0~105°C/32~221°F |
display resolution |
0.1°C/0.1°F |
0.1°C/0.1°F |
|
measurement accuracy |
±1°C/±1.8°F |
±1°C/±1.8°F |
|
Offset calibration |
1 point, measured value ± 10 ° C |
1point,measured value ±10°C |
|
other |
Temperature compensation range |
0~100 ° C/32~212 ° F, automatic |
0~100 ° C/32~212 ° F, manual or automatic |
Temperature compensation coefficient |
— |
Linear (0.0~10.0%/° C) |
|
reference temperature |
— |
25°C |
|
cell constant |
— |
K=0.1, 1, 10 or custom |
|
Data locking |
manual |
manual or automatic |
|
connector |
BNC, 3.5mm microphone plug |
6针DIN |
|
Operating Temperature |
0~50°C |
||
display screen |
LCD display screen (122 × 57mm) |
||
Power type |
AC220V/50Hz |
||
Overall dimensions |
210 (length) × 205 (width) × 75 (height) mm |
||
weight |
1.5kg |
||