E-mail
1415268707@qq.com
-
Phone
13764885152
-
Address
Room 4597, Building 6, No. 1150 Lanfeng Road, Fengxian District, Shanghai
Shanghai Jintong Instrument Co., Ltd
1415268707@qq.com
13764885152
Room 4597, Building 6, No. 1150 Lanfeng Road, Fengxian District, Shanghai
UV1901 seriesDual beam UV visible spectrophotometer英文: UV1900series UV Dual-Beam Visible Spectrophotometer
Display mode: 6-inch 320 × 240 dot matrix digital LCD with backlight
Light source lamp: Hamamatsu environmentally friendly (ozone free) deuterium lamp from Japan, Osram long-life halogen tungsten lamp
Optical system: Precision dual beam optical system
Interface: The RS232C serial communication port is used to connect software, and the parallel printing port is used to connect printers
Spectral scanning function: Host and software support
Power supply voltage: 100V~240V 50/60 ± 1Hz
Instrument size: 650 × 450 × 220 (mm)
Net weight: 25Kg
Product Features
1. UV1900 seriesDual beam UV visible spectrophotometerThe optical system design and circuit control system design are very rigorous, and the selection and control of components are strictly controlled, with high standards of accuracy, repeatability, low noise and low stray light indicators. The linear range and stability indicators are also excellent. There are two configurations, 1nm and 2nm bandwidth, suitable for different users to choose from. The large screen LCD display has high measurement accuracy and stability, making it a high-quality instrument.
The UV1900 series dual beam UV visible spectrophotometer uses Japan's Hamamatsu environmentally friendly (ozone free) deuterium lamp and Osram long-life tungsten halogen lamp, with a service life of up to 2000 hours. The light output can remain stable until its service life, and replacement is extremely convenient.
The UV1900 series dual beam UV visible spectrophotometer offers two operating modes: host measurement mode or software controlled measurement mode.
4. The built-in SCM technology and qualitative and quantitative analysis software can achieve extended functions such as data acquisition and processing, spectral measurement, kinetic measurement, quantitative analysis, DNA determination, and spectral scanning. The menu drop-down analysis software is easy to operate.
5. The UV1900 series dual beam UV visible spectrophotometer has an open sample chamber and can be equipped with reflective sample holder, solid sample holder, constant temperature water bath, and automatic sampler, which are suitable for different applications.
6. Single machine scanning curves can store 9, and working curves can store 9. There is no limit to the amount of storage in online mode.
Main technical indicators
Model: |
UV1901 type |
|
|
★ Optical path structure: Measurement method: |
CT optical path (focal length of 250mm) Transmittance, absorbance, energy, reflectance |
|
Wavelength range: |
190nm~1100nm |
|
|
Spectral bandwidth: Wavelength accuracy: |
1nm ≤±0.3nm |
|
Wavelength repeatability: |
≤0.1nm |
|
★ Luminous range: |
0-999.9%(t),-4A~4A,0-9999C,1-9999F |
|
Luminous accuracy: |
≤±0.3%(t) (0~100%t) ≤±0.002A(0~0.5A) ≤±0.004A(0.5~1A) |
|
Luminous repeatability: |
≤0.15%(t) (0-100%t) ≤0.001A(0~0.5A) ≤0.002A(0.5~1A) |
|
Miscellaneous light: |
≤0.03%(t) (220nm NaI,360nm NaNO2)) |
|
★ Stability: |
≤± 0.0004A/h (500nm, preheating for 30 minutes upon startup) |
|
Noise: |
≤±0.0003A |
|
★ Baseline straightness: |
≤±0.0008A(190~1100nm) |
|
★ Derivative resolution: |
>0.5 |
|
Scanning speed: |
Fast, medium, slow |
|
analysis software
Comfortable operating experience and rich analysis functions - UVCON series qualitative and quantitative data processing and analysis software
Dynamics measurement can determine the time variation of transmittance or absorbance from 1 second to 10 hours, with recording intervals ranging from 0.1 to 60 seconds, allowing for observation of rapid reactions and changes. In the data processing function, there are peak valley detection and derivative operation.
UV1901PC type advantage indicators
model |
UV1901PC type |
★★ Optical path structure |
CT monochromator focal length 250mm |
Display mode: |
6-inch 320 × 240 dot matrix digital LCD with backlight |
★★ Light source lamp: |
Japanese Hamamatsu environmentally friendly (ozone free) deuterium lamp Osram long-life halogen tungsten lamp |
Metering Mode |
Transmittance, absorbance, energy, reflectance |
spectral bandwidth |
1nm |
wavelength range |
190nm~1100nm |
Wavelength accuracy |
≤±0.3nm |
Wavelength repeatability |
≤0.1nm |
★ Luminous Range |
0-999.9%(t),-4A~4A,0-9999C,1-9999F |
Photometric accuracy |
≤±0.3%(t) (0~100%t) ≤±0.002A(0~0.5A) ≤±0.004A(0.5~1A) |
Photometric repeatability |
≤0.15%(t) (0-100%t) ≤0.001A(0~0.5A) ≤0.002A(0.5~1A) |
stray light |
≤0.03%(t) (220nm NaI,360nm NaNO2)) |
★ Stability |
≤± 0.0004A/h (500nm, preheating for 30 minutes upon startup) |
noise |
≤±0.0003A |
★ Baseline straightness |
≤±0.0008A(190~1100nm) |
★★ Derivative resolution |
>0.5 |
scanning speed |
Fast, medium, slow |
★★ Power supply voltage |
50/60 ± 1Hz can be used within the range of 100V to 240V |
|
Instrument size
|
650×450×220(mm) |