ATDS-413 type secondary fully automatic thermal analysis samplerInnovation point:
1. The rotary valve switches to a multi-dimensional gas injection system, completely overcoming the drawbacks of domestic six way valves and ten way valves, such as short service life and inability to withstand high temperatures.
2. The design of the pneumatic process is very simple, reliable, and conducive to leakage prevention, greatly improving work efficiency.
3. The gas path and sample valve through which the sample passes have been treated with inerting technology.
4. The sample tube installation is simple, and the collected sample tube can be directly installed on the sample tray without removing the cap.
5. Fully automatic robotic arm, capable of automatically removing and attaching caps to sample tubes, preventing cross contamination of sample tubes.
6. This product adopts a needle free design, which is used for connecting with the GC or GCMS injection system and sampling the sample tube.
7. The gas circuit adopts EPC electronic pressure control, and the digital display is more intuitive. It can achieve automatic gas path system leak detection and fault alarm.
8. By adjusting the injection time and injection volume, analysis has been conducted on samples of different concentrations.
9. For various standards, 10 methods can be stored.
10. Full color screen display, user-friendly interface, touch operation, can be quickly and easily mastered, tracking and displaying the entire operation process, set parameter values, and real-time values.
11. Expand service scope:
⑴ We can provide customers with experimental device plans, technical consultation, or co construction and sharing for chromatographic analysis sample pretreatment projects;
⑵ Pyrolysis apparatus, functional modules/unit assemblies, and related components, accessories, etc. can be purchased, rented, or exchanged for new.
ATDS-413 type secondary fully automatic thermal analysis samplerGeneral application areas:
1. The composition of volatile aroma and flavor compounds in food, and the determination of residues and pollutants in food.
2. The composition of thermally degradable compounds in solid matrices, such as plasticizers, additives, monomers, etc. in polymer materials (the degradation products of these samples are determined by adsorption thermal desorption analysis, which is helpful for the investigation of arson cases).
3. Unwanted components in the sample matrix, such as residual solvents in pharmaceuticals, residual monomers in polymers, and other oligomers.
4. purposefully collect volatile components in the sample matrix, such as polluted atmosphere, salt, and sugar. At present, the typical application is to use adsorption tubes to collect volatile organic pollutants (benzene derivatives, VOCs) in the air for environmental monitoring.
5. A single thermal analysis is generally only used for lower boiling point temperature components (C2~C13), and inorganic and permanent gases are not easy to perform. If a low-temperature adsorption trap (secondary thermal analysis) is used, it can achieve a boiling point<C36 for volatile samples.
6. It can also be used for special solids or liquids (such as soaking cotton and placing it in a tube).
7. The combination of secondary adsorption pyrolysis and GC/MS has a wider range of applications, which can solve the analysis and determination of complex types of samples, including environment, materials, fuel resources, food, pharmaceuticals, polymers, and various other commodities.
Main technical parameters:
1. One time desorption temperature adjustment range: room temperature~380 ℃, accuracy ± 0.5 ℃, increment 1 ℃ can be set
2. Secondary desorption temperature adjustment range: room temperature~380 ℃, accuracy ± 0.5 ℃, increment 1 ℃, any set heating rate>3000 ℃/min
3. Focusing cold trap temperature adjustment range: room temperature~-40 ℃ (related to indoor temperature) accuracy ± 1 ℃ increment 1 ℃ can be set
4. Temperature adjustment range of sample related pipelines: room temperature~260 ℃, accuracy ± 1 ℃, increment 1 ℃
5. Temperature adjustment range of the six way valve: room temperature~260 ℃, accuracy ± 1 ℃, increment 1 ℃ can be set
6. Part processing in sample transfer: optional, programmable flow rate, adjustable temperature and time of 260 ℃, accuracy of ± 1 ℃, increment of 1 ℃ can be set (such as blowback sample transfer, activation/aging of collection tube, etc.)
7. Controllable quantity of foreign affairs: 15
8. Time control range for foreign affairs: 0.1-99 minutes Timing error range:<0.1%
9. Material and specifications of sample collection tube: stainless steel
10. Material and specifications of capture tube: stainless steel, quartz glass, elastic quartz capillary tube, etc. (optional)
11. One time thermal analysis flow rate: 0-100 ML/min continuously adjustable (with indication)
12. Cylinder driven air pressure:<0.4MPa (adjustable)
13. Pressure resistance of gas circuit and related components:>0.4MPa
14. Batch of sample processing quantity: 50
15. Analysis accuracy: RSD<2.5% (related to GC performance and operational techniques)
16. Performance parameters: Half peak width<3S desorption rate>98% (toluene 0.1ul split 10:1) 17 Instrument power: < 1000VA
18. Linkage signal output switch time:<2 seconds
19. Instrument dimensions: height x width x length 500mm x 485mm x 650mm
20. Weight: Approximately 45 Kg