1.2 Interface Definition


1.3 Definition of indicator lights

1.4 Reference for M12 Ethernet interface on the motherboard
Ethernet uses M12 connectors with "D" encoding, which have a metal shielding shell. The device end adopts a hole type connector, and the M12 connector point is defined as follows:

2. UDP communication interface configuration parameters
Communication method: Ethernet UDP0 communication, the default IP address of this device is 192.168.20.136
Communication port: default to 6666 port (both source and destination ports are 6666)
Communication method: Ethernet UDP1 communication, the default IP address of this device is 192.168.21.136
Communication port: default to 6667 port (both source and destination ports are 6667)
Frame format: frame header+length+data;
The relationship between MCU and TRDP module is master-slave, with MCU as the master and TRDP module as the slave.
u100M forced full duplex Ethernet interface, 2KV electromagnetic isolation, default configuration is MDI mode;
uEthernet comes with an isolation transformer that can withstand a voltage of 2500V;
uThe Ethernet protocol complies with the requirements of IEC61375-2-3 and IEC61375-3-4, and supports TRDP protocol;
uSupport TRDP process data (PD mode) and message data (M)DMode), supports SDTV2Security data;
uEthernet supports TTDB to automatically obtain the dynamic and static topology of trains;
uMACThe address is globally unique;
uEthernet supportDNSMeet the need for communication through domain names;
usupportmanyaTRDPmoduleCOMIDportReceive and send messagesCOMIDdynamic adjustment.
uThe main power supply adopts110V power supply;
uOperating Temperature-40℃ ~ +85℃
ustorageTemperature:-40℃ ~ +85℃
uMaximum relative humidity:90%
uLevel: Industrial grade