The BTX III X-ray diffraction (XRD) analyzer is a compact desktop analyzer that can quickly provide reliable quantitative mineralogical information on the main and secondary components of minerals.
The BTX III analyzer is equipped with a compact sample tray that can replace traditional XRD instruments and is lightweight, requiring almost no maintenance. This standalone instrument can be operated without the need for compressed gas, water cooling devices, secondary chillers, or external transformers, thus maintaining a low cost of ownership. The operator can directly connect the XRD instrument to other devices by using Ethernet or wireless connectivity.
Olympus' XRD analyzer uses the intuitive SwiftMin software with the following features: a single screen control panel displaying multiple data, pre-set calibration programs, easy data export, and automatic data transfer, simplifying the user's workflow.
The improvement of speed and sensitivity helps to make decisions quickly
BTX IIIDesktop X-ray diffraction systemCombining powerful, concise, and intuitive software with improved X-ray detectors not only enhances sensitivity and speeds up the analysis process, but also yields more reliable results.
The updated X-ray detector hardware runs faster and has higher analysis density, resulting in lower detection limits.
SwiftMin automatic mineral phase identification (ID) and quantification software can provide real-time data directly on the XRD analyzer, so you can make decisions quickly, timely, and confidently.
Sample preparation, easy to complete
When using traditional desktop X-ray diffraction instruments, large quantities of samples need to be ground into powder and then rolled into small spherical shapes to ensure sufficient random orientation of the grains.
By contrast,BTX IIIDesktop X-ray diffraction systemA small vibrating sample tray can be used to induce convection of all particles in the sample chamber, ensuring that the data is almost unaffected by directional effects. Therefore, the analyzer only requires 15 milligrams of sample to obtain high-quality detection results, and the sample kit provided with the analyzer can easily prepare the sample.