Daily LR8101/LR8102 data acquisition device

NegotiableUpdate on 05/20
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

A data acquisition device suitable for system integration and expandable modules. Flexible expansion of measurement modules based on the measurement system; One data acquisition device (host) can connect up to 10 measurement modules; $r $n ∝ Supports channel expansion and real-time high-speed data transmission through synchronous sampling between LR8102 hosts.

Product Details

Product Specifications

model

LR8102

LR8101

Connectable module

Voltage and Temperature Module M7102

Voltage and Temperature Module M7100

Power measurement module M7103

Maximum number of modules that can be connected

10 (M7103 up to 4)

Maximum number of synchronized hosts

10 units (requiring optical connection cables)

Unable to synchronize with the host

power supply

AC adapter: AC adapter Z1016 (DC 12V ± 10% drive)

External power supply: DC 10 V~30 V

AC power module M1100: When using power measurement module M7103, it is necessary

Temperature and humidity range for use

-10 ℃~50 ℃, below 80% RH (no condensation)

Number of LAN ports

2

1

communication interface

Collecting data and setting recording conditions through the Logger Utility

Initial setting of IP address through Logger Utility

Use communication commands for setting and recording control

Manually obtain data through FTP server

FTP data automatic transmission (FTP client)

HTTP server functionality

XCP on Ethernet (TCP)

NTP client functionality

Ethernet XCP (UDP)

Output measurement data through UDP

Collecting data and setting recording conditions through the Logger Utility

Initial setting of IP address through Logger Utility

Use communication commands for setting and recording control

Manually obtain data through FTP server

FTP data automatic transmission (FTP client)

HTTP server functionality

XCP on Ethernet (TCP)

NTP client functionality

external media

USB flash drive, ensure normal operation: Z4006 (16 GB)

Support SD/SDHC memory cards to ensure normal operation: Z4001 (2 GB), Z4003 (8 GB)

External control terminal

Pulse/logic input (1), external sampling input (1), external input-output (4), alarm output (4), GND terminal (5), CAN interface (1)

Pulse/logic input (1), external sampling input (1), external input-output (4), alarm output (4), GND terminal (5)

Volume and weight

No module: approximately 80W x 166H x 238D mm (excluding protrusions), 1.5 kg

When installing one M7100 module: approximately 134W × 166H × 263D mm (excluding protrusions)

When installing 10 M7100 modules: approximately 620W x 166H x 263D mm (excluding protrusions)

Attachment

Precautions for use x 1, Startup guide x 1, DVD x 1 (Startup guide, detailed user manual, Logger Utility, Logger Utility user manual, CAN unit setting software, easy to use CAN unit setting software, communication command user manual)

The host does not come with an AC adapter. Please choose the separately sold (optional) AC adapter Z1016, power cord L1012, or AC power module M1100.

When combined with M7103, an AC power module M1100 is required.



Product Options

applicableModule for measuring the voltage of stacked battery cells in battery packs and conducting charge and discharge tests on battery cell production lines

module

Voltage/Temperature Module M7100

Voltage/Temperature Module M7102

battery pack

Suitable for 600 V to 1500 V

Suitable for voltages below 600 V

Maximum rated voltage to ground

DC 1500 V, AC 1000 V (CAT II)

DC 600 V, AC 600 V (CAT II)

Maximum rated voltage between modules

DC 1500 V, AC 1000 V

DC 600 V, AC 600 V

maximum number of channels

15 channels/piece

30 channels/piece

sampling rate

Fastest 5 ms

Fastest 10 ms

More details

Click to view M7100 details

Click to view M7102 details











Modular power measurement module suitable for photovoltaic inverter production line

module

Power measurement module M7103

Maximum rated voltage to ground

DC 1000 V, AC 1000 V (CAT III)

DC 1500 V, AC 1000 V (CAT II)

Measurement range

Voltage: 6 V to 1500 V (8 ranges)

Current: 40 mA~2000 A (6-speed range, depending on sensor)

number of channels

3ch/unit

sampling rate

Fastest 5 ms

More details

Click to view M7103 details