- Phone
-
Address
Room 110, 1st Floor, Zone E, Zhongyin Business Garden, No. 2 Xugongqiao Road, Huaqiao Economic Development Zone, Kunshan City, Jiangsu Province
Shanghai ORIS Automation Technology Co., Ltd
Room 110, 1st Floor, Zone E, Zhongyin Business Garden, No. 2 Xugongqiao Road, Huaqiao Economic Development Zone, Kunshan City, Jiangsu Province
DLHZO-TE-040-L51 Atos ATOS Proportional ValveDLHZO-TE-040-L51 Atos ATOS Proportional Valve
DLHZOandDlkzorThe type valve is a high-performance proportional valve direct acting type,
Sliding sleeve structure, withLVDTPosition sensor, providing directional control and flow control without pressure compensation based on input electrical signals.
Proportional valve and electronic amplifier work together,Amplifier. The electronic amplifier provides an appropriate current signal to calibrate the adjustment of the valve compared to the example valve,Make it correspond to the input signal supplied to the electronic amplifier. This type of valve has different forms to choose from:
1,-T:Equipped with position sensor;
2,TE,-TES:同-TBut with simulation(-TE)Or numbersTESIntegrated electronic amplifier.
3,There is a four-way valve core inside the proportional valve, which can slide in a precision machined and hardened sliding sleeve to achieve the highest covering accuracy.
4,sleeve3Pressed into the five chamber valve bodyDInternally, the valve core is equipped with an integrated inductive electronic sensorLVDTSThe proportional electromagnet is used for closed-loop position control.
5,The integrated amplifier is pre tuned at the factory to ensure excellent performance and valve performance-Valve interchangeability simplifies wiring and installation.
CorrectTESThe digital proportional valve has the following communication interfaces(available:*_PS:RS232Serial communication interface. The input signal of this valve is an analog quantity, which is passed through7core(or12core)Plug provided.
1,_BC:CANbusinterface
2,-BP: PROFIBUS-DPinterface
PheartPDConnect the door-BCand-BPInterface form, the input signal of the valve is provided through the bus, and during startup or maintenance, the input signal of the valve can also be transmitted through7core(or12core)The plug is operated by providing analog signals.
Due to the optimization of the integrated electro-hydraulic system, its excellent dynamic and static characteristics can be compared to servo valves.
Typical advantages of proportional valves:低敏感性,Low filtration requirements, essential stability,Easy to maintain,High reliability.
The coil is fully encapsulated in plastic(HGrade insulation),The whole valve has the characteristics of anti vibration, anti impact, and anti environmental impact. mounting surface:ISO 4401standard06and10Path. maximum flow:In terms of pressure drop=70bartime,Achieve separately40and100 L/min.
maximum pressure350bar
<
<
| DLHZ0-T-040-L31 |
| DLHZO-LE-040-L03/DL27SB40+DPZO-LE-271-L5-40 |
| DLHZO-LE-040-L13/B/DL37SB 40 |
| DLHZO-LEQ-040-V71/LQ53XC |
| DLHZO-LEQ-040-V71/Q/LQ53XC (5) |
| DLHZO-LEQ-060-V31/Q/LQ32SA 70 |
| DLHZO-LEQ-060-V71/Q |
| DLHZO-LEQ-060-V71/Q/LQ52SB 60 |
| DLHZO-LEQ-060-V71/Q/LQ52SB 70 |
| DLHZO-LES-PS-060-V31/AM001A |
| DLHZO-T-040-DT71 31 |
| DLHZO-T-040-L01 31 |
| DLHZO-T-040-L11 31 |
| DLHZO-T-040-L13 31 |
| DLHZO-T-040-L31 |
| DLHZO-T-040-L31 31 |
| DLHZO-T-040-L71 31 |
| DLHZO-T-040-L73 |
| DLHZO-T-040-L73 31 |
| Dlhzo-tech 040 -l 03 31 |
| Dlhzo-tech 040 -l 11 40 |
| DLHZO-TE-040-L11/I 40 |
| Dlhzo-tech 040 -l 13 40 |
| Dlhzo-tech 040 -l 31 40 |
| Dlhzo-tech 040 -l 51 40 |
| Dlhzo-tech 040 -l 51 |
| Dlhzo-tech 040 -l 53 |
| Dlhzo-tech 040 -l 53 40 |
| DLHZO-TE-040-L53/I |
| DLHZO-TE-040-L53/I 40 |
| Dlhzo-tech 040 -l 71 |
| Dlhzo-tech 040 -l 71 40 |
| Dlhzo-tech 040 -l 71 / Z |
| Dlhzo-tech 040 -l 73 40 |
| Dlhzo-tech 040 -l 73 / b 40 |
| DLHZO-TE-040-L73/B+SP-ZN-7P |
| DLHZO-TE-040-L73/Q 40 |
| DLHZO-TE-040-T53/I 40 |
| DLHZO-TE-040-V31 40 |
| DLHZO-TE-040-V71 40 |
| DLHZO-TES-PS-040-L51/1F |
| DLHZO-TES-PS-040-L51/I/F |
| DLHZO-TES-PS-040-L71 |
| DLHZO-TES-PS-040-V11 41 |
| DLHZO-TES-PS-040-V31 41 |
| DLHZO-TES-PS-140-L71/2F |
| Dlhz-y- 040 -l 73 / 1 |
| DLKZA-T-140-L71/PA-GK/7 |
| DLKZA-TES-PS-140-L71/M 11 |
| Dlkzor-a- 171 -s 5.40 / |
| DLKZOR-A-171-S5.40/WG |
| DLKZOR-T-140-L71 |
| DLKZOR-T-140-L71 41 |
| DLKZOR-T-140-L73 41 |
| DLKZOR-TE-140-L33 41 |
| DLKZOR-TE-140-L71 |
| DLKZOR-TE-140-L71 41 |
salt spray test(EN ISO 9227standard)>200h
Follow the rulesCECertification of low voltage indicators2014/35/EURoHscommand2011/65/EUThe latest version2015/65/EUREACHrule(EC)n’1907/2006
insulation class,Protection level meetsDIN EN 60529standard,load factor,voltage and frequency,Allowable voltage fluctuation range
certification,The DC coil isH (180°C)The communication coil isF(155°C),The surface temperature of the electromagnetic coil meets the EU standard specificationsENISO 13732-1andEN ISO 4413
IP 65(Correct installation of plug)10%,CURusNorth American Certification Standards-only forDHEType pilot valve
Installation and usage instructions
This type of valve has different types to choose from:RType, without integrated amplifier, compared to split type amplifierE-BM-RESUsed in conjunction, see technologyGS203REBType,
REBtypebeltbasicType integrated digital amplifier, analog reference signal andUSBInterface is used for setting software functional parametersSet.
RESType, equipped with a fully functional integrated digital amplifier and bus communication interface, used for setting functional parameters, reference signals, and real-time fault diagnosis.
The integrated digital electronic amplifier adjusts the hydraulic pressure of the valve based on the reference signal, with pre adjustment at the factory to ensure interchangeability between valves. specification: 10,20,32.Flow rateachievable: 200,400,600 I/min.pressureachievable: 350 bar.
AGMZ0-RType proportional valve obtainedCECertification mark, compliant withEMCApplication standard specifications such as diamagnetism/anti-interferenceEMCCurrent and Low Voltage Current Standards)Installation, wiring, and startup must be carried out in accordance withF003Operate according to the steps described and install according to the installation instructions corresponding to the relevant components.
Prohibit the use of electronic signals from valves(Like monitoring signals)Directly used as a driving signal for safety functions, such as controlling the opening of machine safety components/This is also regulated by European standards(Safety requirements for fluid systems and components,EN-982).
<
| DLKZOR-TE-140-L71/BI 41 |
| DLKZOR-TE-140-L71/FI 41 |
| DLKZOR-TE-140-L71/I 41 |
| DLKZOR-TE-140-L71/IZ 41 |
| DLKZOR-TE-140-L71+SP-ZH-7P |
| DLKZOR-TE-140-L73 41 |
| DLKZOR-TE-140-L73/B 41 |
| DLKZOR-TE-140-L73/B+SP-ZN-7P |
| DLKZOR-TE-140-L73/IZ 41 |
| Dlkzor -te 140 -l73 / Z |
| DLKZOR-TE-160-L71/I 41 /BT |
| DLKZOR-TE-171-S5 |
| DLKZOR-TES-PS-140-L71/I 41 /PE |
| DLKZOR-TES-PS-140-L71/I/F |
| DLKZOR-TES-PS-140-L73/Q |
| DLOH-2A/PA-NPT-AO/7 24DC 24 |
| DLOH-2A-UX 24DC 21 |
| DLOH-2C/-U-20 |
| DLOH-2C/WP-U24DC |
Product physical photos




Atos Partial Hydraulic Valve Models
<
<
| DLOH-2C-UX 00 21 |
| DLOH-2C-UX 24DC 21 |
| DLOH-2C-UX 24DC 21 /PE |
| DLOH-2C-UX24DC |
| Valve block of DLOH-2C |
| DLOH-3A/R-UX 24DC 21 |
| DLOH-3A/WP-UX 24DC 21 |
| DLOH-3A-U 21 |
| DLOH-3A-UN230AC |
| DLOH-3A-UX 24DC |
| DLOH-3A-UX 24DC 21 |
| DLOH-3A-UX 24DC 21 /PE |
| DLOH-3A-UX 24DC 21 /PE |
| DLOH-3C 220 volts |
| DLOH-3C DC24V |
| DLOH-3C/GK-AO 24DC 24 |
| DLOH-3C/PA-GK-AO 24DC |
| DLOH-3C/S-UN24DC |
| DLOH-3C/WP-UX 24DC |
| DLOH-3C-U-00 21 |
| DLOH-3C-UN230RC |
| DLOH-3C-UN24DC |
| DLOH-3C-U-SP666 24 |
| DLOH-3C-UX 00 |
| DLOH-3C-UX 00 21 |
| DLOH-3C-UX 24DC |
| DLOH-3C-UX 24DC 21 |
| DLOH-3C-UX 24DC 21 /PE |
| DLOK-3A/GK-AO 24DC 22 |
| DLOK-3A-OX 24DC 21 |
| DLOK-3C-OX 24DC 21 |
| DLPX-3C 20 |