ATOS proportional relief valve AGMZO-A-32/315

NegotiableUpdate on 05/14
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

ATOS proportional relief valve AGMZO-A-32/315, supplied by Shanghai Ouruis Automation Technology Co., Ltd. for Atos hydraulic pump valve components. The price is good, the inventory is sufficient, the installation is convenient, and the product declaration form is provided

Product Details

ATOS proportional relief valve AGMZO-A-32/315ATOS proportional relief valve AGMZO-A-32/315

AGMZOCan provide mechanical pressure limiterAs a protection against high voltage. For safety reasons, the factory pre-set mechanical pressure limiter is unloaded(minimum pressure)During debugging, the pressure setting value must be slightly higher than the maximum pressure adjustment value of proportional control. Follow the steps below to set the pressure of the mechanical pressure limiter:

1Provide the amplifier with the maximum input reference signal. The system pressure will not increase until the mechanical pressure limiter is still in the unloaded state

2Rotate the adjusting nut clockwise Until the system pressure increases to a stable value, corresponding to the set pressure value under the maximum reference input signal

3Rotate the adjusting nut clockwise and then rotate it more1or2Circle to ensure that the mechanical pressure limiter remains closed during the operation of the proportional valve

Regarding valvesvent hole

When the valve is first debugged, the air trapped inside the electromagnet must be discharged through a screw plug located at the rear of the electromagnet.

The presence of air can cause unstable pressure and vibration.

Remote pressure unloading

PThe main pipeline can be connected through a valveXPerform remote unloading on the solenoid valve, as shown in the figure on the right(unloading valve)This function is used to divert and unload the system pressure of proportional control in emergency situations.

Pressure sensor malfunction

To prevent the malfunction of the pressure sensor, it is necessary toAtos E-SWParameters of software configuration valve:-Cut off the current to the electromagnet and adjust the pressure to a small value(default settings)-pressure control(PID1.2.3)Automatically switch from closed-loop to open-loop(PID4)The temporary operation of the valve reduces the accuracy of regulation.

This valve'sElectronic amplifier options

Standard amplifier compatible7Core main plug

AGMZO-RAGMZO-REB,AGMZO-RESCone valve type pilot digital proportional relief valve with integrated pressure sensor for pressure closed-loop control.

Installation and usage instructions

This type of valve has different types to choose from:RType, without integrated amplifier, compared to split type amplifierE-BM-RESUsed in conjunction, see technologyGS203REBType,

REBtypebeltbasicType integrated digital amplifier, analog reference signal andUSBInterface is used for setting software functional parametersSet.

RESType, equipped with a fully functional integrated digital amplifier and bus communication interface, used for setting functional parameters, reference signals, and real-time fault diagnosis.

The integrated digital electronic amplifier adjusts the hydraulic pressure of the valve based on the reference signal, with pre adjustment at the factory to ensure interchangeability between valves. specification: 10,20,32.Flow rateachievable: 200,400,600 I/min.pressureachievable: 350 bar.

<

AGMZO-TER-10/210/F 40
AGMZO-TER-10/210/I
AGMZO-TERS-PS-010/210/I
AGMZO-TERS-PS-10/100 52
AGMZO-TERS-PS-10/210
AGMZO-TERS-PS-10/210/ I 50
AGMZO-TERS-PS-10/210/I
AGMZO-TERS-PS-10/210/I
AGMZO-TERS-PS-10/210/I
AGMZO-TERS-PS-10/210/I
AGMZO-TERS-PS-10/210/I 53
AGMZO-TERS-PS-10/315 53
AGMZO-TERS-PS-32/315
AGR20R-A-10/315/P


salt spray test(EN ISO 9227standard)>200h

Follow the rulesCECertification of low voltage indicators2014/35/EURoHscommand2011/65/EUThe latest version2015/65/EUREACHrule(EC)n1907/2006


insulation classProtection level meetsDIN EN 60529standardload factorvoltage and frequencyAllowable voltage fluctuation range

certificationThe DC coil isH (180°C)The communication coil isF(155°C)The surface temperature of the electromagnetic coil meets the EU standard specificationsENISO 13732-1andEN ISO 4413

IP 65(Correct installation of plug)10%CURusNorth American Certification Standards-only forDHEType pilot valve

Installation and usage instructions

This type of valve has different types to choose from:RType, without integrated amplifier, compared to split type amplifierE-BM-RESUsed in conjunction, see technologyGS203REBType,

REBtypebeltbasicType integrated digital amplifier, analog reference signal andUSBInterface is used for setting software functional parametersSet.

RESType, equipped with a fully functional integrated digital amplifier and bus communication interface, used for setting functional parameters, reference signals, and real-time fault diagnosis.

The integrated digital electronic amplifier adjusts the hydraulic pressure of the valve based on the reference signal, with pre adjustment at the factory to ensure interchangeability between valves. specification: 10,20,32.Flow rateachievable: 200,400,600 I/min.pressureachievable: 350 bar.

AGMZ0-RType proportional valve obtainedCECertification mark, compliant withEMCApplication standard specifications such as diamagnetism/anti-interferenceEMCCurrent and Low Voltage Current Standards)Installation, wiring, and startup must be carried out in accordance withF003Operate according to the steps described and install according to the installation instructions corresponding to the relevant components.

Prohibit the use of electronic signals from valves(Like monitoring signals)Directly used as a driving signal for safety functions, such as controlling the opening of machine safety components/This is also regulated by European standards(Safety requirements for fluid systems and components,EN-982).



Product physical photos






Atos Partial Hydraulic Valve Models<


<

<

AGAM-20/10/210
AGAM-20/10/210-IX 230/50/60AC 53 /PE
AGAM-20/10/210-IX24DC
AGAM-20/10/315
AGAM-20/10/350/V
AGAM-20/10/350-IX 24DC 53
AGAM-20/11/210-IX 24DC 53
AGAM-20/11/210-N24DC
AGAM-20/11/350-IN24DC
AGAM-20/11/350-IX 24DC 53
AGAM-20/11/50
AGAM-20/210
AGAM-20/210/V
AGAM-20/22/210-IX230AC
AGAM-20/350/V 53
AGAM-32/10/350/-IX24DC. ........................
AGAM-32/100 53
AGAM-32/11/350/V-IX24DC
AGAM-32/20/350/210-IX 24DC 53
AGAM-32/210
AGIR-10/100
AGIR-10/100 51
AGIR-10/210
AGIR-10/210 51
AGIR-10/210/V
AGIR-10/350
AGIR-20/100 51... Wangwang
AGIR-20/210
AGIR-32/50 41
AGIRR-10/100 51
AGIRR-32/100
AGISR-10/210 12
AGISR-10/210 12 /WG
AGISR-20/210V
AGIU-10/10/100-IX 230/50/60AC 16
AGIU-10/10/100-IX 24DC 16
AGIU-10/100
AGIU-10/11/100/D-IX 24DC 16
AGIU-10/11/100-IX 24DC 16
AGIU-20/10/100/D/V-IN24DC WG
AGIU-20/10/100-IX 230/50/60AC 16
AGIU-20/10/100-IX 24DC 16
AGIU-20/10/100-X 24DC
AGIU-20/10/210-IX 230/50/60AC 16
AGIU-20/10/210-IX 24DC 16
AGIU-20/10/210-X 24DC
AGIU-20/10/350-IX 24DC 16
AGIU-20/210/V 16
AGIU-32/11/350/V-IX 24DC 16
AGMZA/M-A-10/80/M 21
AGMZA/M-A-10/80/PA-GK/7 21
AGMZA-A-10/250/M/24 23
AGMZO-A-010/100
AGMZO-A-010/210
AGMZO-A-010/315 DC24V
AGMZO-A-10/210/6 20
AGMZO-A-10/315 20
AGMZO-A-32/315 20
AGMZO-AE-10/100/I 10
AGMZO-TER-10/210 40
AGMZO-TER-10/210/F 40
AGMZO-TER-10/210/I
AGMZO-TERS-PS-010/210/I
AGMZO-TERS-PS-10/100 52
AGMZO-TERS-PS-10/210
AGMZO-TERS-PS-10/210/ I 50
AGMZO-TERS-PS-10/210/I
AGMZO-TERS-PS-10/210/I
AGMZO-TERS-PS-10/210/I
AGMZO-TERS-PS-10/210/I
AGMZO-TERS-PS-10/210/I 53
AGMZO-TERS-PS-10/315 53
AGMZO-TERS-PS-32/315
AGR20R-A-10/315/P
Agcz-a- 020 / 100
AGRCZO-A-010/100
AGRCZO-A-010/100/P。。。。。
AGRCZO-A-010/315
AGRCZO-A-10/100 20
AGRCZO-A-10/100/P 20
AGRCZO-A-10/210
AGRCZO-A-10/210 20
AGRCZO-A-20/100 20
AGRCZO-A-20/210/R
AGRCZO-AE-10/100 20
AGRCZO-AE-10/100/IR 20
AGRCZO-AE-20/210/P
AGRCZO-AE-20/315/I 20
AGRCZO-AES-PS-10/210/Z 20
AGRCZO-TERS-PS-10/210 53
AGRCZO-TERS-PS-10/315/I 53
AGRL-10
AGRL-10 41
AGRL-10/2
AGRL-10-2
AGRL-20
AGRL-20 41