- Phone
-
Address
Building 1, Block B, Optics Valley International Chamber of Commerce Building, No. 2-2 Guandongyuan Road, Donghu New Technology Development Zone, Wuhan City, Hubei Province
Wuhan Hairaite Automation Engineering Co., Ltd
Building 1, Block B, Optics Valley International Chamber of Commerce Building, No. 2-2 Guandongyuan Road, Donghu New Technology Development Zone, Wuhan City, Hubei Province
DDM-RF1550radarflow meterDDM-RF1550-D02Product Overview:
DDM-RF1550/DDM-RF1550-D02The series radar flowmeter mainly consists of a radar flowmeter and a radar water level gauge. The flowmeter is used to collect the surface flow velocity of the fluid, and the average flow velocity of the cross section is calculated through a model. Then, combined with the water level and section information measured by the water level gauge, the cross section area of the cross section is calculated, and the formula flow rate is used=average flow velocity×Cross-sectional area of overcurrent×The correction coefficient is used to obtain the flow rate, which is calculated based on the standard value obtained from the actual measurement environment.
1.1 Functional Features
DDM-RF1550/DDM-RF1550-D02Series high-precision radar flowmeterNon contact installation design, compact size and structure. High precision, low power consumption, strong anti-interference ability, suitable for water level monitoring of lakes, rivers, flash floods, reservoirs, sewage pipelines, etc.
DDM-RF1550radarflow meterDDM-RF1550-D02Technical parameters:
power supply voltage |
10-16V |
Current(12VPower supply) |
Less than during normal operation150mADuring sleep, it is less than1mA |
Operating Temperature |
-40°~85° |
waterproof rating |
IP68 |
transmission frequency |
24.000 ~24.250GHz |
communication interface |
RS-485 |
communication protocol |
MODBUS-RTU |
measuring range |
0.1~40m |
measurement accuracy |
±2mm |
resolution |
1mm |
Startup time |
10s |
Speed measurement range |
0.1-20m/s |
Accuracy of flow velocity measurement |
±0.01 m/s |
Flow velocity resolution |
0.01 m/s |
Flow direction recognition |
Bidirectional automatic recognition, configurable filtering, default forward direction. |
Flow velocity measurement time |
1 time/s |
Antenna style |
Current Speed:14 x 32゜ Water level:14 x 10゜ |
Flow meter size (length)xwidexHigh) |
200×120×90mm |
Bracket size (length)xwidexHigh) |
100×100×55mm |
weight |
flow meter+Bracket:2.15kg |
housing material |
Galvanized and stainless steel plates |
DDM-RF1550Radar flowmeterOn site installation:
DDM-RF1550/DDM-RF1550-D02seriesThe precautions for installing a radar flowmeter are as follows.
1. Install flow meters, water level gauges, and flow rate gauges with no obstruction to the radar, otherwise it will affect the measurement accuracy.
2. When installing the flowmeter, it is necessary to ensure that the surface of the casing is level as much as possible and installed in the middle of the channel.
3. The beam of the flowmeter is recommended to face the incoming water direction, as shown in the installation diagram, and the horizontal angle with the water flow direction is0Degree.
4. The flowmeter is only affected by dynamic targets. When the channel is hardened without weeds or trees, even if the beam is irradiated on both sides of the channel, it will not affect the flow measurement.
5. Under the same conditions, the higher the installation height, the weaker the echo and the worse the signal quality, especially for scenes with low water flow velocity, where the ripples are small and difficult to measure. At the same time, the radar wave irradiation area will be larger, which may cause the beam to irradiate the canal bank and be affected by the moving targets on the bank. If installed too low, it is not conducive to anti-theft protection, so for pole installation, it is recommended to install within a height range3-4Rice.
6. On site inspection to determine the installation height of the flowmeter and channel parameters