DCS system AO isolation safety barrier

NegotiableUpdate on 12/05
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The DCS system AO isolation type safety barrier, PFEXB-C3D1 series current output type safety barrier, receives 4-20mA current signals from the on-site safety area, and after isolation and linearization processing, converts them into linearized DC current signals or voltage signals and outputs them to the control system or other unit combination instruments in the hazardous area.

Product Details

The DCS system AO isolation type safety barrier, PFEXB-C3D1 series current output type safety barrier, receives 4-20mA current signals from the on-site safety area, and after isolation and linearization processing, converts them into linearized DC current signals or voltage signals and outputs them to the control system or other unit combination instruments in the hazardous area. The AO isolated intelligent voltage safety barrier of DCS system can configure and set the input and output range. The AO isolation type safety barrier of this DCS system requires independent power supply, with three terminals isolated from the input end, output end, and power supply end, with 1 in and 1 out, 1 in and 2 out, and 2 in and 2 out.


DCS系统AO隔离型安全栅

DCS系统AO隔离型安全栅

Main functions and functions

The DCS system AO isolation type safety barrier and PFEXB-C3D1 isolation type safety barrier mainly receive current signals from the safety zone, and after intrinsic safety processing, isolate and output them to the hazardous zone. Devices connected to the site: actuators that collect current or voltage, such as frequency converters, solenoid valves, and electric regulating devices. Can be used for equipment in Zone 0, Zone 1, Zone 2, IIA, IIB, IIC, T1~T6 hazardous areas.

▉ Input circuit (safe zone)

Input terminal numbers Terminal 5/6, 7/8

Input signal 4-20mA, 0-20mA, 0-10mA (or customized range)

Open circuit voltage ≤ 28V


Output circuit (Exia IIC hazardous area)

Output terminal number Terminal 9/10, 11/12 Output signal

Output current 4~20mA, 0~20mA (or customized range)

Current load capacity ≤ 500 Ω (if larger load capacity is required, please customize)

Output voltage 0~5V, 0~10V (or customized range)

Voltage load capacity: 0~5V: ≥ 1M Ω, 0~10V: ≥ 2M Ω

▉ Working power supply

Power terminal 3+, 4- (hot swappable)

Working voltage 18~32V DC

Power indicator LED: green


▉ Environmental conditions

Working temperature -40 ℃~80 ℃

Allow relative humidity of 10~90% RH (40 ℃) during work

Allowable atmospheric pressure during work: 80 Kpa~110 Kpa


Product Structure

Dimensions W22.5 × D100 × H115 (mm)

Weight 170g

Material ABS

Protection level IP20

Flame retardant grade UL94/V0


▉ Installation

Installation method: DIN35mm rail installation