1DC high voltage generatorConductivity current test of valve type lightning arrester.
2DC high voltage generatorDC withstand voltage test and leakage current measurement of power transformers.
3. DC withstand voltage test and leakage current measurement of high-voltage cables (35-500kV and below).
4. U1mA DC reference voltage test and 0.75U1mA leakage current test for zinc oxide lightning arrester.
| Specifications | 200/2 | 200/3 | 200/5 | 300/2 | 300/3 | 300/5 |
| Rated voltage (kV) | 200 | 200 | 200 | 300 | 300 | 300 |
| Rated current (mA) | 2 | 3 | 5 | 2 | 3 | 5 |
| Rated power (W) | 400 | 600 | 1000 | 600 | 900 | 1500 |
| Control box mass (kg) | 5.5 | 6.0 | 6.5 | 6.5 | 6.5 | 7.5 |
| Mass of pressure doubling cylinder (kg) | 10.3 | 10.3 | 10.3 | 11.5 | 11.5 | 11.5 |
| Height of pressure doubling cylinder (mm) | 970 | 970 | 970 | 1250 | 1250 | 1250 |
| voltage accuracy | ± (1.0% reading+2 words) | |||||
| Current accuracy | ± (1.0% reading+2 words) | |||||
| ripple factor | ≤0.5% | |||||
| voltage stability | ≤ 1% when the power supply voltage changes by ± 10% | |||||
| overload capacity | The no-load voltage can exceed the rated voltage by 10% and be used for 10 minutes | |||||
| The maximum charging current is 1.25 times the rated current | ||||||
| power supply | Single phase AC 50Hz 220V ± 10% | |||||
| working method | Intermittent use: rated load for 30 minutes | |||||
| 1.1 times rated voltage usage: 10 minutes | ||||||
| working environment | Temperature: -10 ℃ to+40 ℃ | |||||
| Relative humidity: not exceeding 85% at room temperature of 25 ℃ (no condensation) | ||||||
| Altitude: below 1500 meters | ||||||
| Capacity with capacitive load | The capacitance of the test sample is unlimited | |||||
| Can be charged with 1.5 times the rated current | ||||||
| structural characteristics | Electrical insulation voltage doubling cylinder | |||||
| Air insulation, no leakage concerns | ||||||
| Characteristics of the operation box | High precision 0.75UDC1mA single touch button (accuracy ≤ 1.0%), suitable for testing zinc oxide lightning arresters | |||||
| Overvoltage protection adopts digital dip switch, which is clear at a glance | ||||||
| Portable chassis, more convenient on-site | ||||||
| Rated voltage of lightning arrester (kV) | 10 | 35 | 66 | 110 | 220 |
| DC reference voltage kV | 28 | 90 | 135 | 168 | 314 |
| Equipment selection kV/mA | ZGF - 60 / 2 | ZGF - 120 / 2 | ZGF - 200 / 2 | ZGF - 200 / 2 | ZGF - 400 / 3 |
| Substation voltage level kV | 10 | 35 | 66 | 110 | 220 | 330 |
| Maximum test voltage kV | 47 | 105 | 135 | 192 | 305 | Greater than 400 |
| Equipment selection kV/mA | ZGF - 60 / 2 | ZGF - 120 / 2 | ZGF - 200 / 2 | ZGF - 200 / 2 | ZGF - 400 / 3 | ZGF - 800 / 10 |
| Maintenance and testing level | Level 5 | Level 4 | Level 3 | Level 2 | Level 1 |
| Maximum test voltage kV | 28 | 90 | 168 | 305 | Greater than 400 |
| Equipment selection kV/mA | ZGF - 60 / 2 | ZGF - 120 / 2 | ZGF - 200 / 2 | ZGF - 400 / 3 | ZGF - 800 / 10 |
| Rated voltage of cable Uo/U kV | 3.6 / 6 | 6 / 6 | 6 / 10 | 8.7 / 10 | 21 / 35 | 26 / 35 |
| DC test voltage kV | 17 | 30 | 40 | 47 | 105 | 130 |
| Equipment selection kV/mA | ZGF - 60 / 2 | ZGF - 60 / 2 | ZGF - 60 / 2 | ZGF - 60 / 2 | ZGF - 120 / 3 | ZGF - 200 / 5 |
| Rated voltage of cable Uo/U kV | 6 / 10 | 8.7 / 10 | 21 / 35 | 26 / 35 | 48 / 66 | 64 / 110 | 127 / 220 |
| DC test voltage kV | 26 | 37 | 63 | 78 | 144 | 192 | 305 |
| Equipment selection kV/mA | ZGF - 60 / 2 | ZGF - 60 / 2 | ZGF - 120 / 5 | ZGF - 120 / 5 | ZGF - 200 / 5 | ZGF - 200 / 10 | ZGF - 400 / 5 |
| Rated voltage of cable Uo/U kV | 48 / 66 | 64 / 110 | 127 / 220 | 190 / 330 | 290 / 500 |
| DC test voltage kV | 175 | 275 | 475 | 585 | 775 |
| Equipment selection kV/mA | ZGF - 200 / 3 | ZGF - 300 / 3 | ZGF - 500 / 5 | ZGF - 600 / 5 | ZGF - 800 / 10 |
1. DC high voltage generator has low ripple coefficient, stable and reliable voltage output, no noise, and good reliability
2. Equipped with overvoltage, overcurrent, zero voltage starting and fault protection functions, the voltage protection value can be set and displayed intuitively
3. Voltage and current are displayed digitally, and there are readings when the power is turned on, making it easy to monitor the output status
4. Equipped with 0.75 times voltage conversion, convenient for testing zinc oxide lightning arresters
5. The product has a compact structure, small size, and is easy to carry