- Phone
-
Address
No. 66, Yousong Village, Gongye Road, Longhua Street, Longhua District, Shenzhen City
Shenzhen MiEn Technology Co., Ltd
No. 66, Yousong Village, Gongye Road, Longhua Street, Longhua District, Shenzhen City
Cybertek HCP8030C High Frequency AC/DC Current Probe
bandwidth(-3dB) DC-70MHz
Rise time ≤5ns
Product Overview:
HCP8000The series current probe is a high-frequency current probe capable of measuring both DC and AC simultaneously. Its characteristics include: high bandwidth, which can accurately and quickly capture current waveforms; High precision, within the range of current measurement, with an accuracy of up to1%Meet the needs of most testing fields; Two measurement ranges are available for selection, making it convenient for small current measurements; Automatic demagnetization and zero adjustment function, easy to use; Sound and light overcurrent alarm function, reminding range switching; Electronic touch sensitive button design for longer lifespan; standardBNCOutput interface, compatible with any manufacturer's oscilloscope.HCP8000Series current probes are commonly used in switch mode power supplies, motor drivers, electronic ballastsLEDIn the design and testing applications of lighting, new energy, etc.
HCP8030(C/D/H)Lightweight and easy to use in crowded circuit boards; Small clamps can detect current in tight spaces and can clamp wires with a diameter of up to5mmCan be measured30AContinuous current and50AThe peak current,HCP8030provide50MHzThe bandwidth,HCP8030Cprovide70MHzThe bandwidth,HCP8030Dprovide100MHzBandwidth;HCP8030Hprovide120MHzBandwidth; The probe has30A (10X)and5A (1X)Two ranges can be selected,5A (1X)The range is particularly suitable for small current measurement, with a resolution of up to1mA.
Product Parameters:
Type number |
HCP8030C |
||
bandwidth(-3dB) |
DC-70MHz (picture1.b) |
||
rise time |
≤5ns |
||
Continuous current maximum |
30Arms picture2.b |
||
peak current |
50Apk |
||
range |
5A |
1Xattenuation |
|
30A |
10Xattenuation |
||
Overcurrent alarm value |
5A |
≥5APk |
|
30A |
≥50APk |
||
Current transmission ratio |
5A |
1V/A |
|
30A |
0.1V/A |
||
resolution |
5A |
1mA |
|
30A |
10mA |
||
|
precision (DC,45-66HzMaximum continuous current) |
5A |
±1%±1mA |
|
30A |
±1%±10mA |
||
input impedance |
reference diagram3.b |
||
delay |
probe host |
14ns |
|
BNC (1m) |
5ns |
||
Terminal load requirements |
≥100kΩ |
||
power supply method |
DC 12V/1A(Standard adapter) |
||
Insulated wire voltage |
300V CAT I |
||
Safety meets standards |
EN61010-1: 2010+A1:2019 EN 61010-2-032:2019 |
||
EMCmeet the standard |
EN61326-1:2013 EN61000-3-2:2014 EN61000-3-3:2013 |
||



Cybertek HCP8030C High Frequency AC/DC Current Probe