- Phone
-
Address
Hengzhao Industrial Zone, Songgang Town, Bao'an District, Shenzhen
Shenzhen Orifan Technology Co., Ltd
Hengzhao Industrial Zone, Songgang Town, Bao'an District, Shenzhen
|
Programmable constant temperature and humidity test chamber(Customized baking paint for constant temperature and humidity test chamber) |
|
|
ORF-HWSP015E-3K(Pprogrammable015 1500L E:-40℃3:high-end configurationK: Baking paint) |
|
|
|
|
|
This experimental equipment prohibits:
|
|
| ||
|
1500L |
|
|
W 1000*D 1000*H 1500mmWidth, depth, and height |
|
|
W 1100*D 2100*H 2080mm |
|
|
about700KG |
|
|
W900*D1400*H700mm |
|
| ||
|
The ambient temperature is+25℃, relative humidity ≤85%Under the condition of no sample in the test chamber |
|
|
GB/T 5170.2-1996Temperature testing equipment. |
|
|
-40℃→+150℃ (can be set arbitrarily) |
|
|
20%RH→98%RH(Can be set arbitrarily) |
|
|
≤±0.05℃ |
|
|
≤±0.5% |
|
|
≤±1℃ |
|
|
≤±2%RH |
|
|
about3.2℃/min |
|
|
about1.5℃/min 60→-20 3degree/minute -20→-40 1degree/minute |
|
|
no-load |
|
|
Meet the testing standards |
①GB/T 2423.1-2001experimentALow temperature test method ②GB/T 2423.2-2001experimentBHigh temperature test method ③GJB 150.3-1986high temperature test ④GJB 150.4-1986Low temperature test ⑤IEC68-2-1experimentA: Cold. ⑥GB 11158Technical Conditions for High Temperature Test Chamber ⑦GB/T 2423.2Basic Environmental Testing Regulations for Electrical and Electronic Products - TestingBHigh temperature test method. ⑧GB/T10586-89Damp heat test chamber conditions ⑨GT/T2423.3-93TheGT/T2423.4-93Damp heat test chamber conditions |
|
| ||
|
④ Box door insulation material: high temperature resistant rigid polyurethane foam. |
|
|
①Stainless steel long shaft centrifugal fan:4platform/90W. ② Heater, evaporator, pressure balancing port, adjustable air guide plate, temperature sensor. |
|
|
① Window300x450x40mm 3Layered vacuum tempered glass. ② Flat embedded handle, ③ Door hinge:SUS #304Imported hinges
⑥ Stainless steelSUS #304Adjustable spacing40mmStorage rack track2group ⑦ Lead hole: φ50mm 1a |
|
|
① Single panel door,Open outward, with the hinge on the left and the handle on the right (when facing the front of the box). ② Equipped with observation windowW300xH450Mm defogging tempered glass, Philips lighting fixtures. ③ Window frame/Door frame anti condensation electric heating device. |
|
|
7Inch controller display screen, operation monitoring indicator, fault buzzerUSBcommunication interface |
|
|
Refrigeration unit, compressor water tray, pressure relief device, refrigeration maintenance and repair device |
|
|
Distribution board, cooling fan, main power switch device, branch power switch device |
|
|
|
|
|
Located on the back of the box |
|
| ||
|
Original German blog semi enclosed compressor
|
|
|
Adopting ultra-high efficiencySWEPCold Coal Cold Heat Exchange Design [Made in Sweden](sus#316)】Compared to traditional internal spiral, it has higher efficiency. |
|
|
① Automatically adjust the cold coal flow rate using a computer, effectively removing the heat load of the test sample and its impact on the temperature/Japanese technique Surgical synchronization. ② Compared to traditional design,High control stability and reproducibility, achieving super efficiency of power saving and low humidity. |
|
|
Efficient and energy-saving low-temperature refrigeration system in Europe and America(Air cooled cooling method). |
|
|
|
|
|
Capacity controlled refrigeration system(T2Copper seamless capillary tube. |
|
8.7.Control mode of refrigeration machine |
① The controller of the control system automatically adjusts the operating conditions of the refrigeration machine according to the test conditions. ② Evaporative pressure regulating valve.
|
|
8.8.refrigerant |
DuPont, USAR404aThe ozone depletion index is0)/Non toxic and environmentally friendly composite refrigerant |
|
8.electric control system | ||
8.1controllermodel |
Taiwan, Chinaweiso
|
|
8.2Temperature and humidity controller |
Using original packaging7Inch microcomputer color LCD display touch screen,Wide perspective of Chinese and English expressions,High contrast function with temperature and humidity programmable controller,tool100Group Program1200Segmental memory,Each paragraph99Hour59Min,Can be arbitrarily divided and set,And attach multiple groupsPIDcontrol function. |
|
8.3Controller specifications |
precision:temperature±0.1℃+1digitHumidity±1%R.H+1digit resolution:temperature±0.01℃,humidity±0.1%R.H. temperature slope:0.1~9.9Configurable. Equipped with upper and lower limit standby and alarm functions. Temperature and humidity input signal dry wet bulbPT100x2. 9groupP.I.DControl parameter setting,P. I.DAutomatic calculation. Dry wet bulb automatic calibration. |
|
8.4Screen display function |
Face to face dialogue in painting,No need for button input,Screen direct touch option. Temperature setting(SV)Compared to reality(PV)Value displayed directly. Can display the current program execution number,segment,Remaining time and number of cycles. Accumulated operation time function. The temperature program setting value is displayed as a graphical curve,Real time display of program curve execution function. Having a separate program editing screen,Minimum input per page120Temperature, humidity, and time of each segment. Chinese and English can be switched freely. Fault prompt screen display, historical fault record display. The screen can be adjusted for backlight. The screen display protection function can be timed,TIMEROr manually turn off the settings. |
|
8.5Program capacity and control function |
Available program groups:maximum100A large section, one thousand and two hundredA small paragraph Repeatable command execution:Each command can reach3200Next time. The production of the program adopts a conversational approach,It has functions such as editing, clearing, and inserting. Short term setting0~99Hour59Min. Having power-off program memory,Automatically start and continue executing program functions after power restoration. toolRS-232/485Communication interface. Real time display of graphical curves during program execution. It has the function of automatically adjusting the freezing capacity. It has the function of scheduled startup and shutdown. Having a date,Time adjustment function. Button and screen lock(LOCK)Function. |
|
9. 14Safety protection device | ||
9.1Refrigeration system protection |
Compressor overheating Compressor overcurrent Compressor overpressure |
|
9.2Temperature and humidity protection |
Temperature over temperature protection alarm (screen setting) Test box temperature upper limit protection alarm (independent mechanical adjustable) Heater short circuit fault protection Water shortage and shutdown protection for waterways Humidifier tube water shortage dry burning protection (independent mechanical adjustable) Humidifier tube short circuit fault protection Fan motor overheat protection |
|
3.3other |
earth leakage protection Overload and short circuit protection power failure protection Water shortage shutdown protection |
|
10.Waterway circulation system | ||
10.1 water pump |
submersible pump |
|
10.2 Waterway working mode |
The humidity system operates with a water circuit, and the single temperature (high and low temperature) water circuit enters a sleep state |
|
10.3 Wastewater treatment mode |
During the experiment, the wastewater was automatically discharged, and the humidification tank was equipped with a manual drain valve. The outlet was located on the back of the machine |
|
10.4 Method of adding water |
Front drawer type water inlet, rear automatic water inlet (optional function) |
|
|
The test box is of integral type and can be transported as a whole |
|
|
Maximum shipping size (excluding packaging): refer to "Overall dimensions" Maximum shipping weight (excluding packaging): see "Weight" |
|
|
The user guarantees the following conditions |
|
|
The ground is flat and well ventilated There is no strong vibration around the equipment There is no strong electromagnetic field around the equipment There are no flammable, explosive, corrosive substances or dust around the equipment There is appropriate space for use and maintenance around the equipment, as shown in the following figure:
|
|
|
|
|
power supply
|
AC380Vthree-phase+The load of the protective grounding wire is greater than8KWCurrent greater than30A Allowable voltage fluctuation range:AC(380±22)V Allowable fluctuation range of frequency:(50±0.5)Hz The grounding resistance of the protective grounding wire is less than4Ω Require users to configure corresponding capacity air or power switches for the equipment at the installation site, and this switch must be independently used for the equipment |
|
|
When the equipment is not working, the temperature of the environment should be maintained0℃~+45Within ℃ Humidity should be maintained30%→60%within the scope of |
|
|
|
|
Meet the testing standards |
①GB/T 2423.1-2001experimentALow temperature test method ②GB/T 2423.2-2001experimentBHigh temperature test method ③GJB 150.3-1986high temperature test ④GJB 150.4-1986Low temperature test ⑤IEC68-2-1experimentA: Cold. ⑥GB 11158Technical Conditions for High Temperature Test Chamber ⑦GB/T 2423.2Basic Environmental Testing Regulations for Electrical and Electronic Products - TestingBHigh temperature test method. ⑧GB/T10586-89Damp heat test chamber conditions ⑨GT/T2423.3-93TheGT/T2423.4-93Damp heat test chamber conditions |
| |
|
④ Box door insulation material: high temperature resistant rigid polyurethane foam. |
|
①Stainless steel long shaft centrifugal fan:4platform/90W. ② Heater, evaporator, pressure balancing port, adjustable air guide plate, temperature sensor. |
|
① Window300x450x40mm 3Layered vacuum tempered glass. ② Flat embedded handle, ③ Door hinge:SUS #304Imported hinges
⑥ Stainless steelSUS #304Adjustable spacing40mmStorage rack track2group ⑦ Lead hole: φ50mm 1a |
|
① Single panel door,Open outward, with the hinge on the left and the handle on the right (when facing the front of the box). ② Equipped with observation windowW300xH450Mm defogging tempered glass, Philips lighting fixtures. ③ Window frame/Door frame anti condensation electric heating device. |
|
7Inch controller display screen, operation monitoring indicator, fault buzzerUSBcommunication interface |
|
Refrigeration unit, compressor water tray, pressure relief device, refrigeration maintenance and repair device |
|
Distribution board, cooling fan, main power switch device, branch power switch device |
8.5Program capacity and control function |
Available program groups:maximum100A large section, one thousand and two hundredA small paragraph Repeatable command execution:Each command can reach3200Next time. The production of the program adopts a conversational approach,It has functions such as editing, clearing, and inserting. Short term setting0~99Hour59Min. Having power-off program memory,Automatically start and continue executing program functions after power restoration. toolRS-232/485Communication interface. Real time display of graphical curves during program execution. It has the function of automatically adjusting the freezing capacity. It has the function of scheduled startup and shutdown. Having a date,Time adjustment function. Button and screen lock(LOCK)Function. |
|
9. 14Safety protection device | ||
9.1Refrigeration system protection |
Compressor overheating Compressor overcurrent Compressor overpressure |
|
9.2Temperature and humidity protection |
Temperature over temperature protection alarm (screen setting) Test box temperature upper limit protection alarm (independent mechanical adjustable) Heater short circuit fault protection Water shortage and shutdown protection for waterways Humidifier tube water shortage dry burning protection (independent mechanical adjustable) Humidifier tube short circuit fault protection Fan motor overheat protection |
|
3.3other |
earth leakage protection Overload and short circuit protection power failure protection Water shortage shutdown protection |
|
10.Waterway circulation system | ||
10.1 water pump |
submersible pump |
|
10.2 Waterway working mode |
The humidity system operates with a water circuit, and the single temperature (high and low temperature) water circuit enters a sleep state |
|
10.3 Wastewater treatment mode |
During the experiment, the wastewater was automatically discharged, and the humidification tank was equipped with a manual drain valve. The outlet was located on the back of the machine |
|
10.4 Method of adding water |
Front drawer type water inlet, rear automatic water inlet (optional function) |
|
Customized baking paint for constant temperature and humidity test chamber