Container type standard curing roomSuitable for cement plants, cement product factories, and construction units of building highways, quality inspection units for temperature and humidity control in standard maintenance rooms. It is easy and fast to use, with electronic digital temperature control and precise temperature and humidity control. The temperature and humidity can be controlled at 20 ℃± 1 and above 90%.
Easy to use, automatic temperature and humidity control, adjustable, and good insulation. *Can meet the needs of standardized maintenance work on construction sites and provide repeated maintenance services for construction sites
Container type standard curing roomMain technical parameters
Temperature control accuracy: 20 ± 1 ° C
Temperature control range ≥ 90% (relative humidity)
Heating power: 3KW
Cooling power: < 2KW(
Humidification power: 60W
Power supply stabilization: 220V ± 10% V
Power frequency: 50Hz
Container size: 6×2.4×2.55 meters

Supporting equipment:
small
1 maintenance room control device (wall mounted)
1 stainless steel heating water tank
One negative ion humidifier
One 1.5P cold and warm on/off air conditioner
medium-sized
One fully automatic control device for the maintenance room (cabinet type)
1 stainless steel heating water tank
One negative ion humidifier
One single cooling window unit air conditioner
medium-sized
One fully automatic control device for the maintenance room (cabinet type)
1 stainless steel heating water tank
1 ultrasonic humidifier
One 1.5P cold and warm on/off air conditioner
large-scale
1 set of fully automatic controller
1 set of indoor cooling and heating hanging machine
1 set of 1.5P outdoor refrigeration unit
1 ultrasonic humidifier
4 sets of test block racks that can be placed in the maintenance room [optional]
BYS-IIIType maintenance room fully automatic control deviceSuitable for cement plants, cement product factories, and construction units of highways, scientific research and quality inspection units to regulate and control the temperature and humidity of standard maintenance rooms. It has the advantages of simple installation, easy operation, no need for training, and accurate control.
10Main technical parameters within square meters:
1Power supply voltage: 220V/50Hz
2Temperature control accuracy: 20 ± 1 ℃
3Temperature control range: 4-99 ℃
4Humidity control accuracy: ≥ 95% RH (adjustable)
5Humidification power: 4KW
6Heating power: 4KW
7Cooling power: 4KW
20Main technical parameters within square meters:
1Power supply voltage: 220V/50Hz
2Temperature control accuracy: 20 ± 1 ℃
3Temperature control range: 4-99 ℃
4Humidity control accuracy: ≥ 95% RH (adjustable)
5Humidification power: 8KW
6Heating power: 8KW
7Cooling power: 8KW
FHBS-60 standard curing room fully automatic temperature and humidity control equipment
Main technical parameters
1. Power supply voltage AC: 380V, three-phase four wire
2. Heating output power 7.5KW, output voltage 380V
3. Refrigeration output power 2.3KW, output voltage 380V
4. Humidification output voltage 220V
5. Temperature control 20 ℃± 1.5 accuracy ± 0.1
6. Humidity control 95% RH ± 2 accuracy 10-99.8% RH
The control instrument has a timed humidification function, which automatically humidifies for 10 minutes and stops for 40 minutes.
The working voltage range of the instrument is 85V-265V.
Structure and Working Principle
1. It consists of four parts: control system, humidification system, heating system, and refrigeration system. The temperature and humidity control are automatically exchanged by digital display instruments, without the need for manual control.
2. Working principle:
(1) Temperature control: When the temperature inside the maintenance room is higher than the upper limit set value of the temperature controller, the control system outputs a cooling signal to control the air conditioner. Conversely, when the temperature is lower than the lower limit set value of the temperature controller, the main unit heats up. When the control requirements are met, it automatically returns to a constant temperature state, and this process is repeated to achieve the control goal.
(2) Humidity control: When the humidity in the maintenance room is lower than the set value, the control system outputs a humidification signal, and the main humidifier starts working, causing the indoor humidity to reach 95% or above, and then automatically stops working.
SBY-30BType cement specimen constant temperature water curing boxaccording to the standardGB-17671-1999Method for testing the strength of cement mortarISOThe curing requirements for cement mortar specimens in the law require the design and production of inner tanks and sinks made of stainless steel plates.
Suitable for cement plants, construction units, highway and bridge engineering units, and relevant scientific research and quality inspection departments to perform standard maintenance on the strength and setting time of cement, concrete, and cement product samples.
Technical parameters:
Temperature control accuracy:±0.1℃
Temperature difference inside the box:≤20±1℃
Cooling power:220V~180W
Heating power:1000W
Studio size:180×320×75㎜
Overall dimensions800×850×1600㎜
Test piece can be placed30group Number of drawers:30only
SBY-60BType cement specimen constant temperature water curing boxaccording to the standardGB-17671-1999Method for testing the strength of cement mortarISOThe curing requirements for cement mortar specimens in the law require the design and production of inner tanks and sinks made of stainless steel plates.
Suitable for cement plants, construction units, highway and bridge engineering units, and relevant scientific research and quality inspection departments to perform standard maintenance on the strength and setting time of cement, concrete, and cement product samples.
Technical parameters:
Temperature control accuracy:±0.1℃
Temperature difference inside the box:≤20±1℃
Cooling power:220V~240W
Heating power:1000W
Studio size:180×320×75㎜
Overall dimensions1100×850×1820㎜
Test piece can be placed60group Number of drawers:60only
40×40×160mmCement sand test mold
It's standard“Method for testing the strength of cement mortar(ISOlaw) GB/T17671-1999”The equipment specified in the regulations.
Technical specifications:
Cast iron trial mold;
Mold cavity size(long×wide×deep):140×40×160 mm;
Base appearance*Large size:245×165×60 mm;
net Heavy:≈6.5k
SHBY-40AType mortar standard curing boxSuitable for the maintenance of standard test blocks in various dry powder mortar factories of scientific research quality inspection departments and construction units. Adopting an intelligent temperature and humidity control system, it can correctly command functions such as heating, cooling, and humidification, perform fully automatic switching work, achieve dynamic balance of temperature and humidity inside the box, and realize the state adjustment of specimens and the standard environment for testing.
Technical parameters:
Temperature control accuracy:±1℃
Temperature difference inside the box:≤± 2℃
Humidity control accuracy:±3%RH
Moisture control range:RH45-90%Above(Adjustable)
Power supply voltage:220V±10%
Humidification power:55W
Humidification capacity:400milliliter/hour
Heating power:400W
Cooling power:150W
Dehumidification power:150W
wind Machine:220V 30W
SBY-5Type wet heat curing box
according toGB1345-77TheGB/T17671-1999Designed and manufactured using the "Method for Testing the Strength of Cement Mortar" and technical data provided by the Building Materials Research Institute and relevant departments.
Easy to operate, equipped with electric heating and cooling devices, can be controlled under any temperature and water conditions20±1The use of ℃ for specimen curing provides one of the best equipment for standard curing specimens in large, medium, and small cement plants as well as scientific research departments in construction.
Main technical parameters:
Temperature control range:20℃
Temperature control accuracy: ±1℃
Moisture control range: ≥95%
electricity Source:220V 50HZ
electricity hot Tool:500W
Refrigerant Freon:F12
Compressor power:>145W
Humidification power:50W
heavy Quantity: Approximately175kg
Cement shrinkage test mold 25 * 25 * 280mm
According to JC/T 603-2004 Cement Mortar Drying Shrinkage Test Method, it is used to make 25 × 25 × 280 cement mortar drying shrinkage performance test specimens and expansion cement expansion rate test specimens, with spherical copper nails at both ends. There is also a 25.4 × 25.4 × 285 alkali aggregate trial mold.
Technical parameters:
1. Size: Length 280mm, Height 25mm, Width 25mm
2. The length between the inner sides of the nail heads at both ends should be maintained at 250 ± 2.5mm
3. Net weight: ≈ 7kg
SHBY-40BType concrete standard curing boxaccording toGB1345-99The "Method for Testing the Stability of Cement Standard Consistency, Water Consumption, and Setting Time" is developed, designed, and manufactured based on technical data provided by the Building Materials Research Institute and relevant departments. It is suitable for large, medium, and small cement plants, as well as construction and engineering departments, for the setting and curing of concrete and cement specimens.
Main technical parameters:
1Control humidity temperature:RH95%Above
2Control temperature:20℃±1℃
3Power supply voltage:220V/50HZ
4Heating power:500W
5Cooling power:145W
6Humidification power:45W
7Increase wet Quantity:400milliliter/hour
8Humidifier volume:5.5L
9Box space:
40Btypesingle doorcan be placed150³Concrete test block15Group(45A)Heating tube power500W)
Exterior dimensions (length)×wide×High):1020×630×1460mm
Inner container size (length)×wide×High):600×500×1200mm
JKSType alkali aggregate test box
standardDLTThe "Test Code for Hydraulic Concrete Sand and Gravel Aggregates" requires design and manufacturing, and is suitable for temperature and humidity control during expansion testing of sand and gravel aggregates.
Technical parameters:
Temperature control range: room temperature100℃ (adjustable) water pump power40W
Temperature control accuracy: ±0.2℃
Voltage:380±10%
Moisture control range:1-9999hour
Frequency:50±1HZ
Heating power:6KW
Size:660×530×520(Net height)440mm)
SHBY-40BType concrete standard curing boxaccording toGB1345-99The "Method for Testing the Stability of Cement Standard Consistency, Water Consumption, and Setting Time" is developed, designed, and manufactured based on technical data provided by the Building Materials Research Institute and relevant departments. It is suitable for large, medium, and small cement plants, as well as construction and engineering departments, for the setting and curing of concrete and cement specimens.
Main technical parameters:
1Control humidity temperature:RH95%Above
2Control temperature:20℃±1℃
3Power supply voltage:220V/50HZ
4Heating power:800W
5Cooling power:145W
6Humidification power:45W
7Increase wet Quantity:400milliliter/hour
8Humidifier volume:5.5L
9Box space:
40Btypetop and bottom openingcan be placed150³Concrete test block20Group(60A)Heating tube power800W)
Exterior dimensions (length)×wide×High):1120×630×1550mm
Inner container size (length)×wide×High):700×520×1250mm
SHBY-60BType concrete standard curing boxaccording toGB1345-99The "Method for Testing the Stability of Cement Standard Consistency, Water Consumption, and Setting Time" is developed, designed, and manufactured based on technical data provided by the Building Materials Research Institute and relevant departments. It is suitable for large, medium, and small cement plants, as well as construction and engineering departments, for the setting and curing of concrete and cement specimens.
Main technical parameters:
1Control humidity temperature:RH95%Above
2Control temperature:20℃±1℃
3Power supply voltage:220V/50HZ
4Heating power:1000W
5Cooling power:145W
6Humidification power:45W
7Increase wet Quantity:400milliliter/hour
8Humidifier volume:5.5L
9Box space:
60BTwo doors opencan be placed150³Concrete test block40Group(120A)Heating tube power1000W)
Exterior dimensions (length)×wide×High):1640×620×1470mm
Inner container size (length)×wide×High):1200×500×1100mm
SHBY-90BType concrete standard curing box according toGB1345-99The "Method for Testing the Stability of Cement Standard Consistency, Water Consumption, and Setting Time" is developed, designed, and manufactured based on technical data provided by the Building Materials Research Institute and relevant departments. It is suitable for large, medium, and small cement plants, as well as construction and engineering departments, for the setting and curing of concrete and cement specimens.
Main technical parameters:
1Control humidity temperature:RH95%Above
2Control temperature:20℃±1℃
3Power supply voltage:220V/50HZ
4Heating power:2000W
5Cooling power:145W
6Humidification power:45W
7Increase wet Quantity:400milliliter/hour
8Humidifier volume:5.5L
9Box space:
90Bthree-doorcan be placed150³Concrete test block60Group(180A)Heating tube power2000W)
Exterior dimensions (length)×wide×High):1980×700×1460mm
Inner container size (length)×wide×High):1550×630×1200mm
| Reference price | Negotiable |
model
brand
Manufacturer nature manufacturer
location Cangzhou City
Containerized curing room and mobile standard curing room are suitable for various cement plants, cement product factories, and construction and road construction units. Quality inspection units can control the temperature and humidity of standard curing rooms conveniently and quickly. Electronic digital display temperature control ensures precise temperature and humidity control, with a temperature of 20 ℃± 1 and a humidity of over 95%, which is controllable. The movable standard curing room is converted from a container and has the advantages of easy use, accurate and adjustable temperature and humidity control, good insulation, and reusability. It can meet the needs of standard curing work on construction sites and save costs for the repeated construction of maintenance rooms.
technical indicators
Temperature control accuracy: 20 ± 1 ° C (water type heating tube)
Temperature control range ≥ 90% (relative humidity) (usually for high-power negative ion humidifiers)
Heating power: 2KW
Cooling power:<2KW (standard room air conditioning)
Humidification power: 60W Power supply voltage regulation: 220V ± 10% V Power frequency: 50HZ
Applicable area: 6 * 2.4-meter standard container.
Equipment List: One temperature and humidity controller, one set of sensors, one heating water tank, and one set of negative ion humidifier.
Note: Customized maintenance room test block racks can be processed

|
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
|
|