Welcome Customer !

Membership

Help

Shanghai Aifeisi Precision Instrument Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Shanghai Aifeisi Precision Instrument Co., Ltd

  • E-mail

    79830308@qq.com

  • Phone

    18017867020

  • Address

    Room 901-3948, Building 4, No. 2377 Shenkun Road, Minhang District, Shanghai

Contact Now

Contact angle measuring instrument

NegotiableUpdate on 01/19
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The FCA500A contact angle measuring instrument is mainly used to measure the cleaning effect of wafer production line process monitoring. In addition to measuring contact angle, this series of instruments can also measure and calculate liquid surface/interface tension and solid surface free energy. When a droplet is freely in a space unaffected by a force field, it takes on a spherical shape due to the presence of interfacial tension.
Product Details
The FCA2000A4R contact angle measuring instrument is mainly used to measure the contact angle between liquid and solid, that is, the wettability of liquid and solid, and can also measure the contact angle when the external phase is liquid. This instrument can measure the contact angle of various liquids with various materials, such as block materials, fiber materials, textile materials, nanomaterials, semiconductor materials, silicon wafer materials, etc. Powder samples can also be measured after compression. At the same time, this series of instruments can measure and calculate liquid surface/interfacial tension and solid surface free energy. When a droplet is freely in a space unaffected by a force field, it takes on a spherical shape due to the presence of interfacial tension. However, when a droplet comes into contact with a solid plane, its final shape depends on the relative strength of the internal cohesion of the droplet and the adhesion between the droplet and the solid. When a droplet is placed on a solid surface, it can automatically spread out on the solid surface or exist as a droplet at a certain contact angle with the solid surface. Contact angle measuring instruments have important applications in improving oil extraction rates, flotation of target minerals, clean coal processing, biopharmaceutical materials, semiconductor chip industry, and characterization of non-toxic low surface energy anti fouling materials. In addition, contact angle measurement technology also has important applications in characterizing industries such as ink, cosmetics, pesticides, printing and dyeing, papermaking, fabric finishing, detergents, spraying, and wastewater treatment.

FCA2000A4R型接触角测量仪

The FCA2000A4R contact angle measuring instrument meets the standard:

GB/T 23436-2009 Automotive Windshield Cleaning Fluid

GB/T 24368-2009 Glass Surface Hydrophobic Contaminants Detection Contact Angle Measurement Method

GB/T 24622-2009 Guidelines for Measuring Surface Wettability of Insulators

ISO 15989-2004 Measurement of water contact angle of plastic film and thin plate corona treated film

ASTM C 813-1990 (2004) Standard Test Method for Detecting Hydrophobic Contaminants on Glass Surfaces Using Contact Angle Measurement

ASTM D 5946-2009 Standard Test Method for Corona Treatment of Polymer Films Using a Water Contact Angle Measuring Instrument

ASTM D 7334-2008 (2013) Standard Test Method for Wettability of Coating, Substrate, and Pigment Surfaces Using Forward Contact Angle Measurement

ASTM D 7490-2013 Standard Test Method for Measuring Surface Tension of Solid Coatings, Substrates, and Pigments Using Contact Angle

ASTM G 205-2010 Standard Guide for Determining the Corrosivity of Crude Oil

ASTM D 724-1999 (2003) Standard Test Method for Surface Wettability of Paper (Contact Angle Method)

ASTM D 5725-1999 (2008) Standard Test Method for Surface Moisture and Absorption of Covering Materials Using an Automatic Contact Angle Tester

Wettability of TAPPI T 458 CM-2004 Paper Surface (Contact Angle Method)

SY/T 5153-2007 Determination Method for Wettability of Reservoir Rocks

YC/T 424-2011 Determination of Surface Wettability of Tobacco Paper by Contact Angle Method


FCA2000A4R contact angle measuring instrument parameter indicators:

Sample table size: 120mm * 120mm, electric 360 degree vertical rotation platform 75mm * 65mm

Sample stage movement range: X-axis ± 30mm, accuracy 0.1mm; Y-axis ± 30mm, accuracy 0.1mm; Z-axis 45mm, accuracy 0.1mm

Automatic positioning of the load sample stage: It can achieve measurement methods for multi position circular arrays, rectangular arrays, and custom arrays (fully automatic optional configuration)

Contact angle measurement range: 0-180 °

Contact angle display accuracy: ± 0.01 °

Contact angle measurement accuracy: ± 0.1 °

Surface/Interface Tension Measurement Range: 0-2000mN/m (Suspension Drop Method, Lying Drop Method)

Surface/interface tension display accuracy: 0.01mN/m

Surface free energy methods: One liquid method, Owen's two liquid method, three liquid method, and other multiple methods can be selected

Optical system: 0.7X-5X high-definition positioning variable magnification lens

Optical lens movement stroke: XY axis: ± 6.25mm

Optical lens top-down adjustment: ± 6.5 °

Light source system: 60x60cm LED adjustable monochrome cold light source

Video system: USB 3.0 camera+PC soft control 210 frames per second (optional configuration of 100 frames per second, 300 frames per second, 1000 frames per second or higher)

Video system pixels: 1.3 million, 2.1 million, 3 million, 5 million optional configurations

Video capture method: manual capture, automatic capture, freely set capture speed, interval time of 0.1-3600sec, AVI recording

Injection injection system movement mode: compatible with automatic drip and high-precision manual injection pump system, with a stroke of 25mm and an accuracy of ± 0.01mm

Injection droplet control accuracy: 0.01 μ l~5 μ l (software precise control, droplet automatic touch)

Measurement software: AFES20.1.0, imported high-speed camera acquisition software

Measurement function: Dynamic and static contact angle, forward and backward angles, measurement of rolling angle (optional manual and electric rolling platforms)

Measurement methods: Angle measurement method, three-point height measurement method, one point penetration method, automatic measurement method, geometric fitting method, and other methods are available for selection

Measurement correction: Surface correction, concave convex contact angle measurement, fiber coated droplet correction

Measurement temperature: room temperature (optional 200 ℃/400 ℃ surface electric control temperature system, liquid circulation temperature control platform, pressurization platform, inert gas protection platform)

Data processing: Compare and calculate the left and right corners, take the average, automatically save images and data to the database, export to Excel, and print reports

Instrument material: Plastic imported aviation aluminum, fine surface oxidation treatment

Instrument motion structure: The overall structure of the instrument includes eight dimensional motion adjustment modes

Instrument expansion: Reserved expansion interface, modular and upgradable

Instrument dimensions: 400mm * 760mm * 400mm

Instrument weight: 25Kg

Power supply: 220V 3A50Hz

After sales service: Free software upgrade, free home delivery for installation and debugging in mainland China, unconditional one-year warranty, conditional three-year warranty

FCA2000A4R Contact Angle Measuring Instrument Warranty:

The company provides on-site training on installation, debugging, operation, and maintenance. When there is a problem with the instrument, a response must be received from the user within 24 hours. If on-site handling is required, confirmation must be made within 72 hours. Free warranty for 1 year from the date of acceptance, conditional warranty for 3 years, and lifetime maintenance. This clause is only applicable to domestic users.