- Phone
-
Address
No. 748, Group 7, Wudun Village, Lingang New Area, China (Shanghai) Pilot Free Trade Zone
Shanghai Juwei Instrument Equipment Co., Ltd
No. 748, Group 7, Wudun Village, Lingang New Area, China (Shanghai) Pilot Free Trade Zone
Condensation test chamberJW-2009B-210-1000
Condensation test chamberJW-2009B-210-1000
Condensation test chamberJW-2009B-210-1000
1、 Sample Description
This experimental equipment prohibits:
Testing and storage of samples of flammable, explosive, and volatile substances
Testing and storage of corrosive substance samples
Testing or storage of biological samples
Testing and Storage of Strong Electromagnetic Emission Source Samples
2、 Volume and size
Nominal internal volume: 1000L
Inner box size: W1000×H1000×D1000 mm
Dimensions: W 1520×H1950×D 1470 mm(Height does not include motor and motor cover)
3、 Test environment conditions
The airflow around the equipment is unobstructed, without high concentration dust, corrosive or flammable gases
The ambient temperature is between 5-35 ℃
Relative humidity ≤ 85% RH
Circulating cooling water temperature ≤ 30 ℃
The supply pressure of circulating cooling water is 0.25-0.4MPa (not required for air-cooled equipment)
The temperature change rate meets the relevant standards
4、 Thermal insulationbuilding envelope
Outer wall material: made of spray painted color steel plate, thickness=2.0mm, White gray;Color code9003,
Inner wall material: SUS304 stainless steel plate, thickness=15mm;
The bottom plate surface is made of SUS304 anti slip stainless steel plate.
The load-bearing capacity of the bottom plate inside the box shall not be less than200kg;
Insulation material: 100mm hard polyurethane foam insulation layer
1A φ50mm test hole,Located on the left side of the device,Insulated plug with low thermal conductivity material
Equipped with a plastic cover, the size of the plastic cover matches the size of the test chamber, ensuring that the distance between the plastic cover and the laboratory wall is 10% of the width/depth of the laboratory;
There are ventilation holes on the plastic cover, and there are lead holes on the side of plastic cover 2
5、 Heater
Heating wire overheating, short circuit and short circuit protection, zero crossing switch fluid power controller (SSR), adjustable overtemperature protection, air conditioning channel extreme overtemperature protection, fan motor overheating protection
Heating system: high-efficiency open circuit nickel chromium alloy electronic heater, equipped with dual adjustable over temperature protection devices. Using highly reliable materials to ensure no deformation or failure throughout the entire temperature range, and no generation of gas-liquid impurities. Control method: SSR (Solid State Relay) non-contact temperature control is used throughout the entire process to prevent sparks and static electricity.
Heating wire overheating, short circuit and short circuit protection, zero crossing switch fluid power controller (SSR), adjustable overtemperature protection, air conditioning channel extreme overtemperature protection, fan motor overheating protection
Heating system: high-efficiency open circuit nickel chromium alloy electronic heater, equipped with dual adjustable over temperature protection devices. Using highly reliable materials to ensure no deformation or failure throughout the entire temperature range, and no generation of gas-liquid impurities. Control method: SSR (Solid State Relay) non-contact temperature control is used throughout the entire process to prevent sparks and static electricity.