Welcome Customer !

Membership

Help

Tianjin Bonaijer Technology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Tianjin Bonaijer Technology Co., Ltd

  • E-mail

  • Phone

  • Address

    No. 179, South Street, Xiqu District, Tianjin Development Zone

Contact Now

Cleanert BAP benzo [a] pyrene specific column

NegotiableUpdate on 01/16
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The determination of benzo (a) pyrene in animal and vegetable oils and fats was developed based on the GBT 22509-2008 national standard method. The pre-treatment column in reverse phase high performance liquid chromatography was used. This purification column is based on the principle of chromatography column, which separates non-polar interfering substances in oils and fats from benzo (a) pyrene to remove the interfering matrix in detection.
Product Details

Product Description:

The determination of benzo (a) pyrene in animal and vegetable oils and fats was developed based on the GB/T 22509-2008 national standard method. The pre-treatment column in reverse phase high performance liquid chromatography was used. This purification column is based on the principle of chromatography column, which separates non-polar interfering substances in oils and fats from benzo (a) pyrene to remove interfering matrices in detection. BAP2260-0 is an upgraded product of the low background series, with a controllable ppb level background that meets the testing requirements for export products.

Cleanert®A new method for detecting benzo (a) pyrene in oil was developed by using BAP-3 solid-phase extraction column to extract benzo (a) pyrene from oily samples, followed by elution with dichloromethane. Compared with the method in the national standard GB/T22509-2008, this method has better oil removal effect, stable benzo (a) pyrene recovery rate, less solvent usage, and is more environmentally friendly. The method is also simpler.

BAP operation method:

*Attention: Do not let the column dry up during the entire operation process; When the benzo [a] pyrene standard is dissolved in acetonitrile, it is not miscible with the eluent, which can cause low recovery and instability. Dissolving the standard in toluene can solve this problem.

BAP-3 operation method:

Solid phase extraction column name: Cleanert®BAP-3 (P/N:BAP5006);

(1) For peanut oil, soybean oil, corn oil, sunflower seed oil, rice oil, sesame oil, blended oil, rapeseed oil, olive oil, the solid-phase extraction method is as follows:

(2) For sesame oil, Cleanert needs to be connected in series on BAP-3 ® Si silica gel solid-phase extraction column (500 mg/6 mL), activation and loading steps are the same as above. When rinsing, rinse the tandem column with 5mL of n-hexane first, then discard the silica gel column, and rinse Cleanert again with 5mL of n-hexane®BAP-3 column, followed by elution and concentration according to the above method.