The ET-3T low force electronic thickness gauge is a high-precision thickness measurement instrument suitable for contact lens or artificial lens manufacturers and related researchers. It can measure the thickness of soft contact lenses (contact lenses), soft IOLs or ICLs, and other materials that are sensitive to temperature or moisture content in a constant temperature solution. It can also measure the thickness of hard contact lenses or other materials (such as RGP, corneal reshaping lenses, or scleral lenses) in air or solution.

The ET-3T comes with a heating type constant temperature bath. By precisely controlling the temperature of the bottom plate of the constant temperature bath, the solution in the bath can be controlled in a constant temperature environment, such as simulating the human eye environment at 35 ℃. It can also be equipped with an external constant temperature circulation device to control the solution in the bath at a temperature lower than room temperature.
Technical Specifications:
Measurement resolution: 1 micron
Measurement repeatability: ± 1 micron
Measurement range: 0~1999 micrometers
Reading accuracy: ± 2 micrometers (± 1 micrometer plus ± 1 micrometer rounded off)
Probe force measurement: adjustable (default 0.8~1.0gf)
Standard measuring seat: curvature radius R8 (customizable)
Display: 3.5-bit 0.75-inch LCD screen, refreshing 3 times per second
Zero adjustment: Adjust the knob by about ± 15 microns
Measuring head: 2.3mm diameter, with a flat and polished top
Output: 25 pin RS232 computer port (optional)
Thermostatic bath material: high transparency acrylic and 316L stainless steel
Maximum volume of constant temperature bath: 80mL
Power supply: 220V~50Hz, 5W (host), 100W (thermostat)
Environmental requirements: 15-30 ℃, maximum relative humidity of 90%
Dimensions: W30 * D24 * H20cm (host), W15 * D22 * H12cm (thermostat)
Weight: 5.3Kg (host), 1.4Kg (thermostat)
Control temperature: RT~50 ℃ (when equipped with TC-35 thermostat), the control temperature also depends on the set temperature of the optional external constant temperature cycler.
Temperature fluctuation: relative value ± 0.3 ℃ (relative value refers to the indoor environment with a relatively constant temperature after preheating).
Standard configuration:
ET-3T host (including horizontal kit): 1 unit
Temperature controller TC-35:1 unit
National standard power cord: 2 pieces
Temperature control cable: 1 piece
External temperature probe: 1 piece
Spare silicone tube: 1.5 meters
Glass thermometer: 1 unit
Rinse bottle: 1
Clip lamp: 1 set
Optional configuration:
RS232 computer communication interface and data acquisition software
Original factory calibration kit (including dynamometer and calibration quantity block with built-in certificate)
foot switch
Low thickness gauge block set (300~1000um including Chinese calibration certificate)
Digital dynamometer
Customized measuring seat and auxiliary positioning support
External constant temperature cycler and filter kit