- Phone
-
Address
No. 6 Donggou Industrial Park, Dashimiao Town, Shuangqiao District, Chengde City
Chengde Kaosi Scientific Testing Co., Ltd
No. 6 Donggou Industrial Park, Dashimiao Town, Shuangqiao District, Chengde City
ZGXCast iron pipe cold and hot water circulation testing machine
1、 Purpose:
Cast iron pipe cold and hot water circulation testing machineDesigned according to the European standard EN877, specifically for cold and hot water circulation testing of cast iron pipe systems.
The testing machine can set and display the water temperature of the cold and hot water tanks, the water temperature at the inlet and outlet of the pipeline system, and control the water level of each water tank. The flow rate of each water tank can be manually controlled through gate valves. All parameters are centrally controlled through the console, operated by the PLC program backend, and displayed and controlled in real-time on a 12 inch screen.
The experimental pipeline system consists of multiple sections of cast iron pipes and fittings, forming a U-shaped structure approximately 3 meters long and 1 meter wide. The inlet and outlet are both made of DN50 (outer diameter Φ 60) cast iron pipes. The test pipeline is supported by support frames of different heights.
2、 Structure Overview
The pipeline system cold and hot water circulation testing machine consists of a cold and hot water tank section, cold and hot water pipelines and throttling control section, test pipeline system section, electrical and program control console section, etc.
The test pipeline is supported by support frames of different heights. Strong adaptability and can be used for various types of pipes. The electrical control console is separated from the water tank, ensuring safety and reliability. PLC can be set to be controllable, with a 12 inch color screen simulating dynamic display.
3、 Parameters
1.Laboratory environment temperature: 23 ± 2 ℃
2.Laboratory environment humidity: 50%
3.Hot water tank capacity: 100 liters/2 pieces
4.Cold water tank capacity: 100 liters/2 pieces
5.Hot water tank temperature: room temperature~95 ℃
6.Cold water tank temperature: room temperature~15 ℃
7.Hot water temperature control accuracy: ± 2 ℃
8.Cold water temperature control accuracy: ± 5 ℃
9.Cold water tank refrigeration: single unit refrigeration cabinet power of 6.0kW
10.Heating power of hot water tank: 12kW/each water tank
11.Water inflow per cycle: 30 liters
12.Water inlet time per cycle: 1 minute (can be set)
13.Drainage time per cycle: 2 minutes (adjustable)
14.Hot and cold water circulation time cycle: 4 minutes or any setting
15.Cycle times: arbitrarily set
16.Water source for replenishment: tap water (it is recommended to use pure water to improve the service life of equipment components)
17.Equipped with test tube clamp outer diameter: Φ 60
18.Number of experimental circuits: 1 circuit
19.Main valve flow rate: 70 liters per minute
20.Main valve diameter: DN50
21.Process control: PLC dedicated program control
22.Input power: 35kw
23.
Pipe support method: Stainless steel pipe support frame
24.Tube assembly method: quick clamp
25.Installation method of hot and cold water tanks: 4 water tanks and 2 bodies
26.Water tank liner material: stainless steel plate 304
27.Main cold and hot water pipes: 2-inch stainless steel pipes
28.Main cooling and heating fittings: 2-inch stainless steel fittings
29.Main pipeline connection method: quick clamp