Calibration device for construction quality detector group

NegotiableUpdate on 01/09
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The calibration device for the construction quality detector group is a specialized calibration device developed and produced by our company in strict accordance with the "JF1110-2003 Calibration Specification for Construction Quality Detector Groups". It is used to detect the indication errors of the vertical detection ruler, inner and outer right angle detection ruler, and wedge-shaped plug ruler in the construction quality detector group. The vertical body of the device is composed of stable granite, high-precision micrometer head, and adjustable horizontal granite base.
Product Details

1、 Instrument Introduction:

Calibration device for construction quality detector groupyesOur company strictly follows the "JF1110-2003 Calibration Specification for Construction Quality Detector Group" for research and development and productionA specialized calibration device used to detect the indication errors of vertical inspection rulers, inner and outer right angle inspection rulers, and wedge-shaped plug gauges in the construction quality detector group. The device'sThe vertical body is composed of stable granite, high-precision micrometer head, and adjustable horizontal granite base.

2、 Instrument composition:

This calibration devicefromXR-2000C typeVerticality detection ruler calibration device andThe XR-300Z inner and outer right angle measuring ruler calibration device consists of two instruments.XR-2000C typeVerticality detection ruler calibration devicefor detectionVertical inspection rulerIndication error,XR-300Z Type Internal and External Right Angle Ruler Calibration Device for TestingThe indication error of the inner and outer right angle measuring ruler and wedge-shaped plug gauge.

3、 Working principle:

Calibration device for construction quality detector groupUsing the comparative method for measurement, the standard angle β 1 (sin β 1=L1/R) is composed of the ratio of the distance traveled by the digital micrometer head to the distance L1 between the axis of the rotary shaft and the axis of the guide shaft. The indication error of the verticality detection ruler angle β 2 (sin β 2=L2/R) is compared and measured. The principle is to use the equal drive principle of the digital micrometer head screw pair to convert the rotary motion of the screw into linear motion, and convert the angular displacement of the verticality detection ruler into linear displacement. The indication error Δ L=L2-L1 is represented by the line value.

Measurement principle: L1: digital micrometer head travel distance mm; L2: perpendicularity detection ruler reading mm; β 1: standard angle; β 2: Verticality detection ruler angle; R: The distance between the axis of the rotary shaft and the axis of the guide shaft is mm; Δ L: indication error: mm.

IIIXR-2000C typeStructural diagram and technical parameters of the verticality detection ruler calibration device:

1. The structural diagram is shown in the following figure:

111.png

2. Technical parameters:

(1) Model: XR-2000C;

(2) Height: 1980 ± 1mm;

(3) Digital micrometer resolution: 0.001mm/m;

(4) Digital micrometer head stroke: 0-50mm;

(5) Digital micrometer error: ± 0.004mm.

4、 XR-300Z typeCalibration device for inner and outer square rulersStructural diagram and technical parameters:

1. The structural diagram is shown in the following figure:


222.png

2. Technical parameters:

(1) Model: XR-300Z;

(2) Height: 300mm;

(3) Width: 250mm;

(4) Thickness: 50mm;

(5) Verticality of working faces: 0.01mm/300;

(6) Flatness of working face: 0.005mm;

(7) Digital micrometer resolution: 0.001mm/m;

(8) Digital micrometer head stroke: 0-25mm;

(9) Digital micrometer error: ± 0.004mm;

(10) Flatness of granite slab: 0.005mm (800X300X150);

(11) Granite dimensions: (800X300X150) mm.

5、 Instrument configuration:

1XR-2000C typeVerticality detection ruler calibration device: 1 set (including third-party measurement certificate);

2XR-300Z typeInternal and external right angle measuring ruler calibration device (including wedge-shaped plug gauge detection bracket): 1 set (including third-party measurement certificate);

3. Horizontal adjustment foot: 1 set;

4. User manual: 1 copy;

5. Factory certificate of conformity: 1 copy;

6. Product warranty card: 1 copy;

7. Product packing list: 1 copy.