Phone
15861470643
-
Address
208 Linghu Avenue, Xinwu District, Wuxi City
Jiangsu Dilong Electronic Technology Co., Ltd
15861470643
208 Linghu Avenue, Xinwu District, Wuxi City
I. Overview
The gas conducting cable type liquid level transmitter is a two-wire system,4-20mADC output, 24VDC DC power supply, all parts in contact with the medium are made of stainless steel, and then directly installed on the measuring pipeline. It is extremely convenient to use and widely used in process control and liquid level measurement in industries such as petroleum, chemical, metallurgy, water conservancy, power, food, medicine, environmental control, etc.
2、 Working principle
Principle of static pressure measurement:
When the liquid level transmitter is inserted into a certain depth of the measured liquid, the pressure formula on the sensor facing the liquid level is:P=ρ.g.H + Po
Where:
P: Pressure exerted on the liquid level of the transmitter
ρ: Density of the tested liquid
g: Local gravity acceleration
Po: Atmospheric pressure on the liquid surface
H: Depth of liquid input into the transmitter
At the same time, the pressure of the liquid is introduced into the positive pressure chamber of the sensor through gas guiding stainless steel, and then the atmospheric pressure on the liquid surface is adjustedPo is connected to the negative pressure chamber of the sensor to counteract the Po on the back of the sensor, so that the sensor measures a pressure of ρ. g. H. Obviously, by measuring the pressure P, the liquid level depth can be obtained
3、 Functional Features
Good stability, with long-term stability of 0.2% FS/year at full and zero positions. Within the compensation temperature range of 0-70 ℃, the temperature drift is less than 0.2% FS, and within the entire allowable operating temperature range, it is less than 0.5% FS.
◆Equipped with reverse protection and current limiting protection circuits, the transmitter will not be damaged if the positive and negative poles are reversed during installation. In case of abnormalities
The feeder will automatically limit the current flowWithin 35MA.
Solid state structure, no movable parts, high reliability, long service life.
◆ Easy installation, simple structure, economical and durable.
4、 Main technical parameters
Measurement range: |
0-0.5 meters to 0-200 meters |
Maximum overload: |
Not exceeding the length of the pipe |
Measurement form: |
Investment style |
Accuracy grade |
0.5%F·S |
Power supply voltage: |
24VDC |
Load resistance: |
≤500Ω |
Measurement medium: |
Various non corrosive liquids |
Long term stability: |
± 0.2% F · S/year |
Relative humidity of the environment: |
0~95% |
Compensation temperature: |
0~70℃ |
Operating Temperature |
-10~70℃ |
5、 Structural characteristics
Shell: |
1Cr18Ni9Ti |
Main structural material: |
polyethylene |
Sensor form: |
Oil filled core diffusion silicon sensor |
self-respect |
Ordinary type 2kg, with digital display head type 2.5kg |