COD tester

NegotiableUpdate on 12/21
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The MD 200 COD tester uses LED light source and high-quality interference filter, and the colorimetric groove does not contain mechanical moving parts, ensuring accurate and reliable testing. The main feature is that several commonly used analysis parameters are pre-set, ranging from single parameter testers to 6-in-1 testers, allowing users to choose the appropriate model according to their actual application needs. Adopting ergonomic design, the structure is compact and the operation is comfortable and simple.
Product Details

MD 200CODtesteradoptLEDThe light source and high-quality interference filter, as well as the colorimetric groove without mechanical moving parts, thereforeCan ensure accurate and reliable testing. The main feature is that several commonly used analysis parameters are pre-set, ranging from single parameter testers to6The all-in-one tester allows users to choose the appropriate model according to their actual application needs. Adopting ergonomic design, the structure is compact and the operation is comfortable and simple.

MD 200CODtesterTechnical features:

  • A high-performance interference filter that does not drift during testing
  • Automatically remember the last selected test parameters
  • Auto Power Off
  • Real time clock and date
  • There is a special calibration mode
  • Backlit display screen
  • Can store test results
  • Zero adjustment once, always effective
  • High waterproof grade

Supporting reagents,1box25Support:

  • 3-150 mg/l COD
  • 15-300 mg/l COD
  • 20-1500 mg/l COD
  • 200-15000 mg/l COD

Multiple sets:

Single parameter set:CODOzone.

2-in-1 set: residual chlorine/pHCopper/pHChlorine dioxide/pH

Three in one set: residual chlorine/pH/Bromine; residual chlorine/pH/Cyanuric acid; residual chlorine/pH/Acidity; residual chlorine/pH/methyl orange alkalinity

Four in one set: residual chlorine/pH/Cyanuric acid/Acidity; residual chlorine/pH/Cyanuric acid/Alkalinity of methyl orange; residual chlorine/pH/acidity/Urea; residual chlorine/pH/Chlorine dioxide/acidity3

Five in one set: residual chlorine/pH/Cyanuric acid/Calcium hardness/Acidity; residual chlorine/pH/Cyanuric acid/Calcium hardness/methyl orange alkalinity

Six in one set: residual chlorine/bromine/pH/Cyanuric acid/Calcium hardness/Acidity; residual chlorine/bromine/pH/Cyanuric acid/Calcium hardness/Alkalinity of methyl orange; residual chlorine/pH/Cyanuric acid/copper/iron/methyl orange alkalinity


Technical Specifications:

optical system

LEDLight source,4In an interference filter3a

430 nm Δ λ = 5 nm

530 nm Δ λ = 5 nm

560 nm Δ λ = 5 nm

610 nm Δ λ = 6 nm

Wavelength accuracy

± 1 nm

Test accuracy

3%FS(Calculated based on standard solution)

Absorbance resolution

0.01 A

power supply

4a5Number battery, usable53Hour or15000time

Auto Shutdown

Auto Power Off

display screen

Backlit LCD screen

data store

16group

interface

Infrared transmission interface

other performance

Real time clock and date

calibration

Factory calibration and user-defined calibration

size

190X110X55 mm

weight

455g

ambient temperature

5-40Temperature and humidity:30-90%

Standard Certification

CE