Product features: Equipped with frequency and RS485 output, it can be used as a multi parameter sensor and networked with the monitoring system to achieve online monitoring. It is equipped with 3 batteries, and the use time of a single battery can last up to 48 hours. The built-in sampling air pump extracts gas from outside the cabin, and after closed-loop circulation, the temperature and humidity sensor can be placed separately outside the cabin. It is the only comprehensive monitoring instrument that covers mine gas and environmental parameters. Sensor structure: CO2, CH4, CO, O2, differential pressure built-in, temperature and humidity external battery working time: After the measuring device is charged normally, its methane, carbon monoxide, oxygen, carbon dioxide, hydrogen sulfide, temperature and humidity, and differential pressure parts should work for no less than 48 hours. Battery capacity: 5000 Ah. Technical parameters of the lithium-ion battery suction sampling pump for lithium manganese oxide mining lamps: positive pressure: 50kPa, negative pressure: 20-30kPa. Working time: 48h. Tester life: 2 years. Protection level: IP54. Free consultation hotline: 400-996-7771

Product Details

CD8 Multi Parameter TesterThe (hereinafter referred to as the measuring device) can simultaneously and continuously detect the concentrations of eight parameters including methane, carbon dioxide, carbon monoxide, oxygen, hydrogen sulfide, temperature, humidity, and differential pressure, and can also trigger an alarm for exceeding the limit.
The measuring device adopts a dual power supply mode of lithium battery and external explosion-proof power supply.
The measuring device comes with two output modes: frequency and RS485, which can be connected to the monitoring system.
Suitable for all places that require testing of environmental conditions, such as mines, firefighting, confined spaces, chemical engineering, environmental protection, emergency response, etc., with safety and environmental capabilities
Composition of models
The instrument is named as follows:
C D 8
Quantity parameters: 8 types
First characteristic code: Multi parameter gas
Product type code: Tester
1.3 Execution standard: Enterprise standard Q/LT 006-2011 "CD8 Multi parameter Gas Tester"
1.5 Explosion proof type: intrinsic safety and explosion-proof type.
1.6 Structure
Dimensions (length x width x height): 220mm x 140mm x 52mm;
Weight: Approximately 2.5 kg


Product features:
Equipped with frequency and RS485 output, it can be used as a multi parameter sensor and connected to the monitoring system for online monitoring
Configure 3 batteries, each with a usage time of up to 48 hours
Built in sampling air pump, extracts gas from outside the cabin, and circulates it in a closed loop before discharging it outside the cabin
The temperature and humidity sensor can be placed separately outside the cabin
The only comprehensive monitoring instrument covering mine gas and environmental parameters
Sensor structure: CO2, CH4, CO, O2, built-in differential pressure, external temperature and humidity
Battery working time:
After the measuring device is charged normally, the working time of its methane, carbon monoxide, oxygen, carbon dioxide, hydrogen sulfide, temperature and humidity, and differential pressure parts should not be less than 48 hours.
Battery capacity: 5000 Ah lithium-ion battery for lithium manganese oxide mining lamps
Technical parameters of suction sampling pump: positive pressure: 50kPa, negative pressure: 20-30kPa
Working hours: 48 hours;
Tester lifespan: 2 years
Protection level: IP54