- Phone
-
Address
No. 85 Xigang North Road, Haigang District, Qinhuangdao City
Qinhuangdao Xunling Technology Development Co., Ltd
No. 85 Xigang North Road, Haigang District, Qinhuangdao City
Qinhuangdao Xunling Technology Development Co., Ltd. is the agent of Japan's Donghe Electric Co., Ltd., and all regular models are in stock.
supplyALL SITESJapan's Donghe ElectricCD-A1SA-050TheTSD-A 1 sa- 050Capacitive level switch.
CD-A1SA-050 Capacitive Level Gauge Durable, Imported from TOWA, Japan.
1CD-A1SA-050 level gauge, manufactured by Toho Electric in Japan-Parameter Specifications
power supply voltage |
AC100/200V-10%~+20% 50/60Hz |
Install |
threadedR1’’ |
power consumption |
2.0VA |
terminal output |
1CrelayAC250V 3A(Resistance to load) DC30V 3A(Resistance to load) |
work pressure |
980kPa(depending on specifications) |
Protect the structure |
IP65 |
Paint color |
Munsell 10YR7.5/14 |
Stable detection range |
high sensitivity0.5~ General sensitivity10PF low sensitivity2~20PF Ultra low sensitivity5~100PF 20PFabove Note: Sensitivity bands can be used during initial settingsDIPSwitch between switches |
Allowable temperature |
Outside the tank-10~60℃ inside the can-20~80℃ |
timer function |
Enable delay, timed time0about10Seconds (variable)
|
2、 Main features
Because there is no driving component, it ensures long-term stability.
The body type comes with a built-in detection sensitivity switch.
The independent amplification circuit performs well in maintenance and upkeep.
3、 Introduction and Principle
Capacitive level switch is based on capacitive technology, which applies radio frequency to the probe and continuously analyzes the surrounding environment. Due to the different dielectric constant and conductivity of all media compared to air, the small changes in capacitance caused by the probe coming into contact with the media are detected by the circuit and converted into switch signal output. its*The anti adhesion circuit only responds to changes in capacitance caused by changes in material level, thereby eliminating false signals generated by material accumulation. In the past, capacitive level switches were supplied considering the dielectric constant of the tested object, selecting sensitivity for optimal detection, and adjusting various electrodes separately. For this reason, Japan's East JapanTOWACombining the previous high sensitivity, general sensitivity, low sensitivity, and ultra-low sensitivity4Sensitivity configuration in the same category1In the amplifier, sensitivity selection can be implemented by switching the switch. For a variety of electrodes, it also has a wide range of adjustment functions corresponding to it. Based on this situation, even if you are already using a large number of different specificationsTSSeries products can also be purchased with an amplifier for maintenance. Imported capacitive level switch.
Four other specification series
CD-A1SA-050(Pole length)500mm), TSD-A 1 sa- 050(Pole length)500mm)
TSD-A1SA-050 UpgradesubstituteCD-A1SA-050
CD-A1SAseries,rod lengthLCustomizable
CD-A1SA-025 L-250mm; CD-A1SA-030 L-300mm;
CD-A1SA-035 L-350mm; CD-A1SA-040 L-400mm;
CD-A1SA-045 L-450mm; CD-A1SA-050 L-500mm;
CD-A1SA-055 L-550mm; CD-A1SA-060 L-600mm;
CD-A1SA-065 L-650mm; CD-A1SA-070 L-700mm;
CD-A1SA-075 L-750mm; CD-A1SA-080 L-800mm;
CD-A1SA-085 L-850mm; CD-A1SA-090 L-900mm;
CD-A1SA-095 L-950mm; CD-A1SA-100 L-1000mm 。
CD-A1SA-050Main features
1. Because there is no driving component, it ensures long-term stability
2. Integrated built-in detection sensitivity switch
3. The independent amplification circuit performs well in maintenance and upkeep.
4. Integrated type, amplifier separation type, explosion-proof type, multiple variations *.
CD-A1SA-050 Capacitive Level Gauge Durable, Imported from TOWA, Japan.