Product Features
Four electrically isolated CAN channels;
Configure the baud rate of four CAN channels through RS232 port: 5Kbps~1Mbps;
Powerful CAN message receiving and filtering function, which can effectively avoid the forwarding of unwanted messages;
Adopting a 32-bit high-speed ARM processor, the port data throughput can reach up to 7000fps;
Long term sending errors will be automatically detected, effectively avoiding network congestion;
Compliant with CAN 2.0B specification and ISO/DIS11898 standard;
All CAN channels are equipped with electrical isolation protection, with an isolation voltage of 2500Vrms
There are power, device status, and bus activity/error indicator lights.
Working voltage: 9~24 VDC
Working temperature: -25 ℃~75 ℃;
Humidity: 5% -95% RH, no condensation.
Appearance and dimensions

Electrical parameters
|
parameter name |
symbol |
rated value |
unit |
||
|
minimum |
typical |
maximum |
|||
|
power supply voltage |
VCC |
9 |
12 |
30 |
V |
|
operating current |
Pm |
- |
160 |
- |
mA |
|
Bus signal (voltage between CAN_S and CAN_L) |
|
-30 |
- |
30 |
V |
|
Working environment temperature |
Tamb |
-25 |
|
75 |
℃ |
Unless otherwise specified, the parameters listed in the table above refer toTamb=25The value at ℃.