Welcome Customer !

Membership

Help

Pusheng Technology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Biopac physiological signal acquisition and analysis system from the United States

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Our company's general agent in Greater China is BIOPAC, a US company that produces human or animal multi-channel physiological signal recording systems. The MP160 16 multi-channel physiological signal recording system is currently the most widely used and functional digital multi-channel physiological signal recording system in the world, which can run on desktop computers and laptops. The MP160 host has a recording sampling rate of up to 400000 points per second (400KHz), 16 bit A/D conversion, can be networked, and can be cascaded and extended to 64 channel signal recording.

Product Details

Our company's general agent in Greater China is BIOPAC, a US company that produces human or animal multi-channel physiological signal recording systems. The MP160 16 multi-channel physiological signal recording system is currently the most widely used and functional digital multi-channel physiological signal recording system in the world, which can run on desktop computers and laptops. The MP160 host has a recording sampling rate of up to 400000 points per second (400KHz), 16 bit A/D conversion, can be networked, and can be cascaded and extended to 64 channel signal recording.


The AcqKnowledge software is available in WIN or MAC versions, allowing for measurement and calculation of data on a computer. The software provides multiple calculation functions, including smoothing, superposition, differentiation, integration, Fourier transform, spectral analysis, etc., for signals. The software is flexible and convenient, and users can add calculation formulas according to their needs to help you obtain data results more quickly.


The independent amplifier series is rich, and each amplifier is optimized for various signals. Its panel provides gain and high-low pass filtering knobs. Different types of amplifiers and sensors can be used to measure bioelectricity, blood pressure, respiration, muscle tone, body temperature, skin resistance, pulse volume, blood oxygen saturation, lung function, blood perfusion and flow rate, invasive/non-invasive cardiac output, cell potential, oxygen/carbon dioxide gas concentration, and support constant current/constant pressure stimulation output. Combining SuperLab or E-Prime can conduct stimulus presentation experiments and synchronize event labeling.

Wired amplifier series
DA100C Universal Amplifier, ECG100C ECG Amplifier, EEG100C EEG Amplifier, EMG100C EMG Amplifier, EOG100C Ophthalmic Amplifier, EGG100C Gastrointestinal Electrical Amplifier, ERS100C Evoked Potential Amplifier, RSP1000 Respiratory Amplifier, EDA100C Skin Electrical Amplifier, SKT100C Body Temperature Amplifier, EBI100C Bioelectric Impedance Amplifier, MCE100C Microelectrode Amplifier, LDF100C Laser Doppler Flow Module, GRS100C Skin Response Amplifier, PPG100C Optoelectronic Volume Amplifier, NIBP100D/D-HD/E/E-HD Non invasive Blood Pressure Measuring Instrument, OXY100E/OXY200/OXY300-MRT Blood Oxygen Saturation Module, STM100C/STM-100C 200 stimulus output module, CO2100C carbon dioxide gas measurement module, O2100C oxygen measurement module, NICO non-invasive cardiac output module

Wireless/telemetry amplifier series

  • Dual channel bioelectric module: BN-ECG2 dual channel electrocardiogram, BN-EEG2 dual channel electroencephalography, BN-EGG2 dual channel gastrointestinal electricity, BN-EMG2 dual channel electromyography, BN-EOG2 dual channel electrooculography

  • Dual channel sensor module: BN-RSP2 dual channel respiration, BN-SKT2 dual channel temperature, BN-GONIO dual channel joint angle, BN-STRIKE dual channel toe heel impact

  • Dual channel combination module: BN-RSPEC respiration+electrocardiogram, BN-PPGED photoelectric volume+skin electricity, BN-NICO cardiac output, BN-DYNEMG grip strength meter+electromyography

  • Other modules: BN-ACCL three-axis acceleration (three channels)

Intelligent amplifier 100D series
The Smart Amps 100D series is a compact amplifier module designed specifically for recording high-quality bioelectric and sensor signals. Smart Amps are small in size, lightweight, and offer exceptional ease of use. Simply insert an amplifier into the AMI100D interface module and perform fast, automatic setup and calibration in the AcqKnowledge software. Easy to use, start recording high-quality data within minutes.

The types of amplifiers include:

  • Bioelectric amplifier: ECG100D (electrocardiogram), EEG100D (electroencephalography), EGG100D (gastrointestinal electricity), EMG100D (electromyography), fEMG100D (facial electromyography), EOG100D (electrooculography), ERS100D (evoked potential)

  • Sensor amplifier: EDA100D (skin electric), PPG100D (pulse), RSP100D (respiration), SKT100D (body temperature)

  • Impedance amplifier: NICO100D (cardiac output), EBI100D (thoracic impedance)



BioNomadix Logger

BioNomadix Logger is a wireless logger that can be paired with three dual channel transmitters simultaneously (compatible with BN series)
A column transmitter is used to wirelessly receive physiological signals from the subjects 24 hours a day and store them in a built-in memory card. In Logger
Equipped with auditory feedback speaker, tactile feedback vibrator, sound recording, event tagging, and alarm, and including three channel ACC
Three axis accelerometer.
Logger can also synchronize GPS and record the correlation between physiological signals and location data.


SmartCenter Portable Wireless Physiological Record Analysis System


Essence Plus


● Easy to use and portable acquisition unit and wireless receiver, can be paired with three dual channel transmitters simultaneously, suitable for extensive research
Recording physiological signals in the field.
● Portable and compact physiological platform, simply plug the acquisition unit into the computer, set up and put on the transmitter for the subjects, and enjoy a few minutes
High quality data can be collected through ACK software within the clock.
The transmitter automatically detects and pairs, and can detect the transmitter's battery level. Follow the built-in wizard program of the ACK software to easily access it
Complete the setup, automatically configure derivative parameter channels, and provide analysis guidance.
● Smart Center provides essence version and enhanced version, supports all transmitters, collects multiple physiological parameters, and velcro straps
Convenient to fix the transmitter to different parts of the body.
The Smart Center acquisition unit does not require a battery and can be powered by simply connecting to a computer USB interface. BioNomadix
The transmitter is powered by a lithium battery and comes with a charger.
● Purchase BN-SMART-IOCBL line to access digital input signals; When used for stimulus/response research, it is used to record data from
Synchronization signal for SuperLab or E-Prime.
ACK software provides excellent automated collection, calculation analysis, and reporting tools. Cited by thousands of references.
*Each computer can only connect to one Smart Center at a time and cannot be connected to other physiological data acquisition systems of BIOPAC
Unified use simultaneously.

MPMS200 Micro Pressure Measurement System

MPMS200 is a single channel, handheld fiber optic micro pressure measurement system used for monitoring physiological pressure, capable of measuring: intravascular pressure
Urodynamics, intracranial pressure, intrauterine pressure, intraocular pressure, and cardiac assist applications.
• Used with TSD280 series sensors with a diameter of 0.30mm (1F)
• Using white light polarization interferometry (WLPI) technology * provides accurate and reliable measurement of FP cavity length
• Compact and sturdy design
High resolution and accuracy, 250Hz sampling rate
• Easy integration with BIOPAC physiological signal acquisition and analysis system
• Provide sensors that can be used for MRI recording
• Automatic atmospheric pressure correction


Solution for using BIOPAC physiology analyzer in MRI environment

By adding the following kit, various physiological parameters can be measured using a physiological instrument in a nuclear magnetic environment.



Bioelectric signal lines and filters - MECMRI-BIOP
Used for direct connection to any of the following bioelectric amplifiers: ECG100C-MRI, EEG100C-MRI, EMG100C-MRI, EGG100C, EOG100C
AMI100D Connection and Filter - MECMRI-AMI
Used for direct connection to the following sensors: TSD115-MRI or TSD131-MRI
DA100C Connection and Filter - MECMRI-DA
Used for direct connection to the following sensors: TSD104A-MRI (pressure sensor), medium speed airflow sensor (TSD117A-MRI), or grip strength gauge (TSD121B-MRI)
TRANS Connection and Filter - MECMRI-TRANS
Used to directly connect the following sensors and amplifiers: EDA100C-MRI, PPG100C-MRI, RSP100C or SKT100C
STM Connection and Filter - MECMRI-STMIO
Used to directly connect the following stimulus isolation adapters: STM100C to STMIOC/D/E; STM200 connected to CBL207


Experimental animal electrode/sensor series

Non invasive electrode/sensor series for experimental human body

美国Biopac公司生理信号采集分析系统