Beijiale Digital Input Module X67DI1371

NegotiableUpdate on 05/12
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Beijiale digital input module X67DI1371; This module is a 24 VDC digital input module equipped with 8 input terminals for receiving input circuits.

Product Details

Beijiale Digital Input Module X67DI1371Wuhan Baishi Automation Equipment Co., Ltd., originating from Austria, specializes in selling products with real photos and original factory packaging. Customers can buy and use with peace of mind. Common products in stock supply, welcome new and old customers to inquire and purchase!



B&R Digital Input Module

Material number:

X67DI1371

Description:

Suitable for all standard sensors with M8 connectors

Extremely short cycle time

Integrated sensor power supply with short-circuit protection function

This module is a 24 VDC digital input module equipped with 8 input terminals for receiving input circuits.

Short description

8 24 VDC digital inputs for input/output modules

General Information

B&R ID code 0x1434

The input/output function, power supply voltage, and bus function of each channel of the status indicator light

diagnosis

Input/output power supply Yes, use LED status indicator light

connection type

X2X connector M12, B code

Input interface 8 M8, 3 pins

Input/output power interface M8, 4-pin

power consumption

Internal input/output 1 W

X2X link power supply 0.75 W

certification

CE, yes

UKCA is

ATEX Zone 2, II 3G Explosion proof Class Ex nA IIA T5 Gc

IP67,Ta = 0 - 60°C

TÜV 05 ATEX 7201X

UL cULus E115267

Industrial control equipment

HazLoc cCSAus 244665

Process control equipment

Used in hazardous areas

Class I, Zone 2, Groups ABCD, T5

KC, yes

Input/output power supply

Rated voltage24 VDC

Voltage range: 18 to 30 VDC

Comprehensive protection function reverse polarity protection

power consumption

Sensor power supply 12 watts

digital input

Rated voltage24 VDC

Input characteristics in accordance with EN 61131-2 Type 1

Input voltage 18 to 30 VDC

Typical value of input current at 24 VDC is 7 mA

Input circuit current injection

Input filter

Hardware ≤ 100 μ s

Software 1 millisecond

Typical value of input resistance 3 k Ω

Sensor power supply 0.5 A total current

switching threshold

low level<5 VDC

high level>15 VDC

The insulation voltage between the channel and the busbar is 500 Veff

sensor power supply

Voltage: Input/output power supply voltage minus voltage drop during short-circuit protection

During short-circuit protection, the voltage drops to 2 VDC at 500 mA

Total current 0.5 A

Anti short circuit is

electrical properties

Electrical isolation

Channel and bus isolation

The channel is not isolated from the channel

Operating conditions

Installation direction

Anything is

Installation altitude

0 to 2000 meters without restrictions

>For every 100 meters increase from 2000 meters, the ambient temperature decreases by 0.5 ° C

According to EN 60529 standard, the protection level is IP67

environmental conditions

temperature

Operating temperature range: -25 to 60 ° C

Reduced amount-

Storage temperature range: -40 to 85 ° C

Transportation temperature range: -40 to 85 ° C

mechanical properties

dimension

Width 53 millimeters

Height 85 millimeters

depth42 millimeters

weight170 grams

Connecting torque

M8 torque 0.4 Nm

M12 torque 0.6 Nm


B&R Digital Hybrid Module X67DM1321L12

Material number:

X67DM1321.L12

Description:

16 digital channels, configurable as input or output

Replacement of passive distributor

2 additional channels with counter function

All outputs have single channel diagnostic function

Extensive additional status information

This module is equipped with 16 digital channels that can be configured as inputs or outputs. The input terminal is designed for the receiving circuit, and the output terminal is designed for the source circuit.

Short description

I/O module with 16 digital channels, can be configured as input or output using software, and the input has additional functions

General Information

The insulation voltage between the channel and the busbar is 500Veff

Nominal voltage 24 VDC

B&R ID code 0x1A1D

Sensor/actuator power supply 0.5 A total current

Status indicator I/O function, power supply voltage, bus function for each channel

diagnosis

The output is, using LED status indicators and software

The I/O power supply uses LED status indicators and software

connection type

X2X link M12, B code

Input/output 8x M12, A code

Input/output power supply M8, 4-pin

power consumption

Internal I/O 3 W

X2X link power supply 0.75 W

certification

CE is

UKCA is

ATEX 2 区, II 3G Ex nA IIA T5 Gc

IP67,Ta=0-60°C

TÜV 05 ATEX 7201X

UL certification E115267

Industrial control equipment

HazLoc cCSAus 244665

Process control equipment

Used in hazardous areas

Class I, Zone 2, Groups ABCD, T5

KC is

I/O power supply

Nominal voltage 24 VDC

Voltage range 18 to 30 VDC

Integrated protection function reverse polarity protection

power consumption

Sensor/actuator power supply value. 12 watts

Sensor/actuator power supply

Voltage input/output power supply negative pressure drop short circuit protection

0.5A short-circuit protection voltage drop. 2 volts DC

Total current. zero point five one

Anti short circuit is

digital input

Input characteristics comply with EN 61131-2 type 1

Input voltage 18 to 30 VDC

24 VDC typical input current. 4.4 milliampere

Input circuit receiver

Input filter

Hardware ≤ 10 µ s (channels 1 to 4)/≤ 70 µ s (channels 5 to 16)

The default value of the software is 0 ms, which can be configured at intervals of 0.2 ms between 0 and 25 ms

Enter the type of resistance. 5 kΩ

Additional features include 50 kHz event counting and gate measurement

switching threshold

Low<5 VDC

High voltage>15VDC

Event counter

Quantity 2

Signal form: square wave pulse

Evaluate each negative side, loop counter

Input frequency. 50 kHz

Counter 1 Input 1

Counter 2 Input 3

Counter frequency value. 50 kHz

Counter size 16 bits

Gate time measurement

quantity 1

Signal form: square wave pulse

Evaluate positive negative edge

Counter frequency

Internal 48 MHz, 3 MHz, 187.5 kHz

Counter size 16 bits

The pause time between pulses is ≥ 100 µ s

Pulse length ≥ 20 µ s

Supported Input 2 or Input 4

digital output

Variable current source FET

Switch voltage input/output power supply minus residual voltage

Nominal output current 0.5A

Total nominal current 8A

Output circuit source

Thermal shutdown during overcurrent or short circuit protection, integrated protection for switch inductor loads, and reverse polarity protection for output power supply

Diagnostic status output monitoring, delayed by 10ms

The leakage current when the output is turned off is 5 µ A

After overload shutdown, turn on the device approximately. 10ms (depending on module temperature)

When the nominal current is 0.5A, the residual voltage is less than 0.3V

Peak short-circuit current<12A

Switching delay

0 → 1<400µs

1 → 0<400µs

switching frequency

Resistive load. 100 Hz

Braking voltage 50 VDC when turning off inductive load

electrical properties

Electrical isolation

Channel and bus isolation

The channel is not isolated from the channel

Operating conditions

Installation direction

Anything is

Installation altitude

0 to 2000 meters without restrictions

>The ambient temperature drops by 0.5 ° C every 100 meters at a distance of 2000 meters

Protection level meets EN 60529 IP67

environmental conditions

temperature

Operation -25 to 60 ° C

Downgrade-

Storage -40 to 85 ° C

Transport -40 to 85 ° C

mechanical properties

dimension

Width 53 millimeters

Height 155 millimeters

Depth 42 millimeters

Weight 320 grams

Connecting torque

M8 0.4Nm

M12 0.6Nm


B&R Digital Hybrid Module X67DM9321

Material number:

X67DM9321

Description:

8 digital channels, configurable as input or output

Node number switch for setting X2X link address

Output with short-circuit protection

All outputs have single channel diagnostic function

Configurable input delay

2 additional channels with counter function

This module is equipped with 8 digital channels that can be configured as inputs or outputs. The input terminal is designed for the receiving circuit, and the output terminal is designed for the source circuit.

The node number switch used to set the X2X link address is a unique feature. When the configuration of modular machines changes, for example, it is necessary to define certain module groups at a fixed address that is independent of the previous module on the production line. All subsequent standard modules reference this offset and automatically use it for addressing purposes.

Short explanation

The input/output module has 8 digital channels, which can be configured as input or output using software. The input has additional functions

General Information

The insulation voltage between the channel and the busbar is 500Veff

Nominal voltage 24 VDC

B&R ID code 0x199B

Sensor/actuator power supply 0.5 A total current

Status indicator I/O function, power supply voltage, bus function for each channel

diagnosis

The output is, using LED status indicators and software

The I/O power supply uses LED status indicators and software

connection type

X2X link M12, B code

Input/output 8x M8, 3-pin

Input/output power supply M8, 4-pin

Electricity consumption

Internal I/O 2.5 W

X2X link power supply 0.75 W

Certification Certificate

CE is

UKCA is

ATEX 2 区, II 3G Ex nA IIA T5 Gc

IP67,Ta=0- 高60°C

TÜV 05 ATEX 7201X

UL certification E115267

Industrial control equipment

HazLoc cCSAus 244665

Process control equipment

Used in hazardous areas

Class I, Zone 2, Groups ABCD, T5

KC is

I/O power supply

Nominal voltage 24 VDC

Voltage range 18 to 30 VDC

Integrated protection with reverse polarity protection

Electricity consumption

Sensor/actuator power supply high value. 12 watts

Sensor/actuator power supply

Voltage input/output power supply negative pressure drop short circuit protection

0.5A short circuit protection voltage drop. 2 volts DC

The total amount of high current. zero point five one

Anti short circuit is

digital input

Input characteristics comply with EN 61131-2 type 1

Input voltage 18 to 30 VDC

24 VDC typical input current. 4 milliamps

Input circuit receiver

Input filter

Hardware ≤ 10 µ s (channels 1 to 4)/≤ 70 µ s (channels 5 to 8)

The default value of the software is 0 ms, which can be configured at intervals of 0.2 ms between 0 and 25 ms

Enter the type of resistance. 5 kΩ

Additional features include 50 kHz event counting and gate measurement

switching threshold

Low<5 VDC

High voltage>15VDC

Event counter

Quantity 2

Signal form: square wave pulse

Evaluate each negative side, loop counter

High input frequency. 50 kHz

Counter 1 Input 1

Counter 2 Input 3

The counter frequency is high. 50 kHz

Counter size 16 bits

Gate time measurement

quantity 1

Signal form: square wave pulse

Evaluate positive negative edge

Counter frequency

Internal 48 MHz, 3 MHz, 187.5 kHz

Counter size 16 bits

The pause time between pulses is ≥ 100 µ s

Pulse length ≥ 20 µ s

Supported Input 2 or Input 4

digital output

Variable current source FET

Switch voltage input/output power supply minus residual voltage

Nominal output current 0.5A

Total nominal current 4A

Output circuit source

Thermal shutdown during overcurrent or short circuit protection, integrated protection for switch inductor loads, and reverse polarity protection for output power supply

Diagnostic status output monitoring, delayed by 10ms

The leakage current when the output is turned off is 5 µ A

After overload shutdown, turn on the device approximately. 10ms (depending on module temperature)

When the nominal current is 0.5A, the residual voltage is less than 0.3V

Peak short-circuit current<12A

Switching delay

0→1<400µs

1→0<400µs

switching frequency

High resistance load. 100 Hz

Braking voltage 50 VDC when turning off inductive load

Electrical performance

Electrical isolation

Channel and bus isolation

The channel is not isolated from the channel

operating conditions

Installation direction

Anything is

Installation altitude

0 to 2000 meters without restrictions

>The ambient temperature drops by 0.5 ° C every 100 meters at a distance of 2000 meters

Protection level meets EN 60529 IP67

environmental conditions

temperature

Operation -25 to 60 ° C

Downgrade-

Storage -40 to 85 ° C

Transport -40 to 85 ° C

mechanical properties

size

Width 53 millimeters

Height 85 millimeters

Depth 42 millimeters

Weight 190 grams

Connecting torque

M8 is 0.4 Nm in size

M12 high value. 0.6 Nm


B&R Digital Hybrid Module X67DM9331.L12

Material number:

X67DM9331.L12

Description:

8 digital channels, configurable as input or output

Output can handle up to 2A of current

Node number switch for setting X2X link address

Replacement of passive distributor

All outputs have single channel diagnostic function

Extensive additional status information

This module is equipped with 8 digital channels that can be configured as inputs or outputs. The input terminal is designed for the receiving circuit, and the output terminal is designed for the source circuit. The output can load up to 2 A. The total current is 8 A.

The node number switch used to set the X2X link address is a unique feature. When the configuration of modular machines changes, for example, it is necessary to define certain module groups at a fixed address that is independent of the previous module on the production line. All subsequent standard modules reference this offset and automatically use it for addressing purposes.

Short explanation

Input/output module with 8 digital channels, which can be configured as input or output using software

General Information

The insulation voltage between the channel and the busbar is 500Veff

Nominal voltage 24 VDC

B&R ID code 0x1B15

Sensor/actuator power supply

Sensor/actuator current 0.1 A

Total current 0.5A

Status indicator I/O function for each channel, sensor/actuator power supply for each channel, power supply voltage, bus function

diagnosis

The output is, using LED status indicators and software

The I/O power supply uses LED status indicators and software

The sensor/actuator power supply uses LED status indicators and software

connection type

X2X link M12, B code

Input/output 8x M12, A code

Input/output power supply M8, 4-pin

Electricity consumption

Internal I/O 1.7 W

X2X link power supply 0.75 W

Certification Certificate

CE is

UKCA is

ATEX 2 区, II 3G Ex nA IIA T5 Gc

IP67,Ta=0- 高60°C

TÜV 05 ATEX 7201X

UL certification E115267

Industrial control equipment

HazLoc cCSAus 244665

Process control equipment

Used in hazardous areas

Class I, Zone 2, Groups ABCD, T5

KC is

I/O power supply

Nominal voltage 24 VDC

Voltage range 18 to 30 VDC

Integrated protection with reverse polarity protection

Electricity consumption

Sensor/actuator power supply high value. 12 watts

Sensor/actuator power supply

Voltage input/output power supply negative pressure drop short circuit protection

0.5A short circuit protection voltage drop. 2 volts DC

The total amount of high current. zero point five one

Anti short circuit is

digital input

Input characteristics comply with EN 61131-2 type 1

Input voltage 18 to 30 VDC

24 VDC typical input current. 4.4 milliampere

Input circuit receiver

Input filter

Hardware ≤ 70 μ s

The default value of the software is 0 ms, which can be configured at intervals of 0.2 ms between 0 and 25 ms

Enter the type of resistance. 5 kΩ

switching threshold

Low<5 VDC

High voltage>15VDC

digital output

Variable current source FET

Switch voltage input/output power supply minus residual voltage

Nominal output current 2A

Total nominal current 8A

Output circuit source

Thermal shutdown during overcurrent or short circuit protection, integrated protection for switch inductor loads, and reverse polarity protection for output power supply

Diagnostic status output monitoring, delayed by 10ms

The leakage current when the output is turned off is 5 µ A

After overload shutdown, turn on the device approximately. 10ms (depending on module temperature)

When the nominal current is 2A, the residual voltage is less than 0.5 V

Peak short-circuit current<21 A

Switching delay

0→1<250µs

1→0<270µs

switching frequency

High resistance load. 100 Hz

Braking voltage 50 VDC when turning off inductive load

Electrical performance

Electrical isolation

Channel and bus isolation

The channel is not isolated from the channel

operating conditions

Installation direction

Anything is

Installation altitude

0 to 2000 meters without restrictions

>The ambient temperature drops by 0.5 ° C every 100 meters at a distance of 2000 meters

Protection level meets EN 60529 IP67

environmental conditions

temperature

Operation -25 to 60 ° C

Downgrade-

Storage -40 to 85 ° C

Transport -40 to 85 ° C

mechanical properties

size

Width 53 millimeters

Height 155 millimeters

Depth 42 millimeters

Weight 325 grams

Connecting torque

M8. 0.4 Nm in size

M12 high value. 0.6 Nm


B&R Digital Output Module X67DO9332.L12

Material number:

X67DO9332.L12

Description:

8 digital outputs

Output can handle up to 2A of current

Node number switch for setting X2X link address

1: 1. Replace the passive distributor

All outputs have single channel diagnostic function

Extensive additional status information

This module is a digital output module with 8 channels. The output can load up to 2 A. The total current is 8 A.

The node number switch used to set the X2X link address is a unique feature. When the configuration of modular machines changes, for example, it is necessary to define certain module groups at a fixed address that is independent of the previous module on the production line. All subsequent standard modules reference this offset and automatically use it for addressing purposes.

Short explanation

Input/output module with 8 digital outputs at 24 VDC

General Information

B&R ID code 0x2658

Status indicator I/O function for each channel, actuator power supply for each channel, power supply voltage, bus function

diagnosis

The output is, using LED status indicators and software

The actuator power supply uses LED status indicator lights and software

The I/O power supply uses LED status indicators and software

connection type

X2X link M12, B code

Output 8x M12, A code

Input/output power supply M8, 4-pin

Electricity consumption

Internal I/O 1.7 W

X2X link power supply 0.75 W

Certification Certificate

CE is

UKCA is

ATEX 2 区, II 3G Ex nA IIA T5 Gc

IP67,Ta=0- 高60°C

TÜV 05 ATEX 7201X

UL certification E115267

Industrial control equipment

HazLoc cCSAus 244665

Process control equipment

Used in hazardous areas

Class I, Zone 2, Groups ABCD, T5

KC is

I/O power supply

Nominal voltage 24 VDC

Voltage range 18 to 30 VDC

Integrated protection with reverse polarity protection

Electricity consumption

High value of actuator power supply. 12 watts

digital output

Quantity 8

Variable current source FET

Nominal voltage 24 VDC

Switch voltage input/output power supply minus residual voltage

Nominal output current 2A

Total nominal current 8A

Output circuit source

Thermal shutdown during overcurrent or short circuit protection, integrated protection for switch inductor loads, and reverse polarity protection for output power supply

Actuator power supply

Actuator current 0.1 A

Total nominal current 0.5A

Diagnostic status output monitoring, delayed by 10ms

The leakage current when the output is turned off is 5 µ A

After overload shutdown, turn on the device approximately. 10ms (depending on module temperature)

When the nominal current is 2A, the residual voltage is less than 0.5 V

Peak short-circuit current<21 A

Switching delay

0→1<250µs

1→0<270µs

switching frequency

High resistance load. 100 Hz

Braking voltage 50 VDC when turning off inductive load

Actuator power supply

Voltage input/output power supply negative pressure drop short circuit protection

500mA short circuit protection voltage drop. 2 volts DC

The total amount of high current. zero point five one

Anti short circuit is

Electrical performance

Electrical isolation

Channel and bus isolation

The channel is not isolated from the channel

operating conditions

Installation direction

Anything is

Installation altitude

0 to 2000 meters without restrictions

>The ambient temperature drops by 0.5 ° C every 100 meters at a distance of 2000 meters

Protection level meets EN 60529 IP67

environmental conditions

temperature

Operation -25 to 60 ° C

Please refer to the "Reduction" section for details on the reduction.

Storage -40 to 85 ° C

Transport -40 to 85 ° C

mechanical properties

size

Width 53 millimeters

Height 155 millimeters

Depth 42 millimeters

Weight 330 grams

Connecting torque

M8. 0.4 Nm

M12。 0.6 Nm


B&R Power Supply Module X67PS1300

Material number:

X67PS1300

Description:

Electrical isolation of power supply and X2X Link power supply

Redundancy protection when multiple system power modules run in parallel

short circuit protection

overload protection

The power module of this system converts the 24 VDC input/output power supply voltage into an electrically isolated X2X link power supply. This module provides 15W output power to other X67 modules on the bus.

Short explanation

System power module electrical isolation X2X link power supply

General Information

The input voltage and output voltage of the status indicator light are normal

connection type

X2X link power output M12, B code

X2X Link power input M8, 4-pin

Electricity consumption

Internal 3W

Certification Certificate

CE is

UKCA is

ATEX 2 区, II 3G Ex nA IIA T5 Gc

IP67,Ta=0- 高60°C

TÜV 05 ATEX 7201X

UL certification E115267

Industrial control equipment

HazLoc cCSAus 244665

Process control equipment

Used in hazardous areas

Class I, Zone 2, Groups ABCD, T5

KC is

X2X link power input

Nominal voltage 24 VDC

Voltage range 18 to 30 VDC

Nominal current 0.75A

Fuse integration

X2X Link power output

Nominal voltage 20 VDC

Nominal current 0.75A

Nominal output power 15W

Efficiency>80%

Parallel connection is

Redundant operation means that the input voltage is equal

When 24 VDCin and IOUt=0.75 A, power failure bridging>5 ms

Overload characteristics: anti short circuit, anti overload

Insulation voltage between input and output 500 Veff

I/O power supply

Nominal voltage 24 VDC

Voltage range 18 to 30 VDC

Integrated protection with reverse polarity protection

Electrical performance

Electrical isolation between X2X Link power supply and X2X Link power supply

operating conditions

Installation direction

Anything is

Installation altitude

0 to 2000 meters without restrictions

>The ambient temperature drops by 0.5 ° C every 100 meters at a distance of 2000 meters

Protection level meets EN 60529 IP67

environmental conditions

temperature

Operation -25 to 60 ° C

Downgrade-

Storage -40 to 85 ° C

Transport -40 to 85 ° C

mechanical properties

size

Width 53 millimeters

Height 85 millimeters

Depth 42 millimeters

Weight 225 grams

Connecting torque

Large M8. 0.4 Nm

M12 high value. 0.6 Nm

Beijiale Digital Input Module X67DI1371