The battery pack high and low temperature water cooling testing system is a cooling unit specially developed and produced by Aoxu Zhaochen for the energy storage industry. With the development of new energy technology, the application of containerized energy storage systems in new energy, photovoltaics, and power stations is gradually increasing. The high performance and high stability technical requirements of the cooling system of dedicated containerized energy storage systems are also being emphasized.
1、 System core architecture
Battery Pack High and Low Temperature Water Cooling Testing SystemAdopting modular integrated design, consisting of five core modules:
Container type machine roomProvide integrated physical installation space with protective performance to ensure stable system operation.
Battery Management System (BMS)Real time monitoring of battery status, intelligent management of charging and discharging processes, and providing safety protection.
Battery pack temperature control systemAs the core of heat dissipation, it covers components such as chillers, pipelines, air conditioners, and air ducts to achieve precise temperature control.
Energy Storage Converter (PCS)Efficiently convert AC/DC electrical energy and achieve flexible energy allocation in energy storage systems.
fire protection systemEquipped with professional fire extinguishing devices to build a solid defense line for the safe operation of the system.
Among them, the chiller, chiller pipes, air conditioning, and air ducts in the temperature control system cooperate with each other to create a stable and suitable environmental temperature for the container energy storage system, ensuring the performance of each component.
2、 Heat dissipation mechanism
During the operation of containerized energy storage systems, lithium battery systems BMS、 Components such as energy storage monitoring generate a large amount of heat due to changes in current. For different working conditions, the system adopts a graded heat dissipation strategy.
routine operating conditionsThe air conditioning refrigeration system dissipates heat through air ducts to improve the overall ambient temperature.
High load operating conditionsStart the dedicated water-cooled chiller unit and directly cool the battery cluster through coolant circulation to ensure efficient operation of the system.
Taking the distributed energy storage power system as an example, the internal fan coil unit directly adjusts the local temperature, the refrigeration unit provides a cold source, and the cooling tower supplies cooling water to the refrigeration unit, forming a closed-loop heat dissipation system and effectively improving heat dissipation efficiency.
3、 Advantages of specialized energy storage chiller technology
(1) Precise temperature control
Equipped with an imported precision digital temperature controller, it achieves high-precision control of water temperature within ± 0.5 ℃, with a temperature setting range of 0 ℃ -55 ℃, meeting the stringent requirements of high and low temperature testing.
(2) Performance
Efficient coolingHigh performance compressors combined with intelligent electronic control systems can quickly respond to temperature changes and significantly shorten cooling time.
energy conservation and consumption reductionAutomatically adjust the cooling power according to the actual load, reducing energy consumption by more than 30% compared to traditional solutions.
Stable muteSmooth and noiseless operation, the compressor can intelligently switch to a safe operating state, ensuring uninterrupted work 24/7.
(3) Flexible selection
Standard ModelProvide conventional models with integrated frequency conversion, including 15kW, 20kW, 25kW, and 45kW.
customized serviceSupport side exhaust or upper exhaust methods, customizable according to the layout of the computer room; The protection level can be increased to IP54 or above to meet special requirements such as non-standard power. For details, please consult the pre-sales engineer.
4、 Core value of battery pack high and low temperature water cooling testing system
1. Extend battery lifeBy precise temperature control, the loss of batteries caused by high temperatures can be reduced, and the battery life cycle can be extended by 20% -30%.
2. Strengthen security protectionThe closed-loop water cooling system effectively avoids the risk of thermal runaway, coupled with a fire protection system, providing dual safety protection.
3. Wide scene adaptationSuitable for various fields such as energy storage power stations, new energy vehicle battery testing, data center backup power supply, etc., to meet diverse heat dissipation needs.