Tianjin Tianguang New Optical Instrument Technology Co., Ltd. is a state-owned enterprise with a history of 50 years in the production of physical optical instruments. Our factory's series of infrared spectrophotometers, ultraviolet spectrophotometers, and clarity detectors have been widely used in research institutes, colleges and universities, as well as various levels of drug testing institutes and pharmaceutical factories, and have a good reputation.
BJ-III disintegration time limit testerIt is a drug testing instrument that performs disintegration time limit testing on tablets, capsules, and pills according to the Pharmacopoeia of the People's Republic of China.
The instrument has the characteristics of simple appearance, reliable performance, reasonable structure, high temperature and time control accuracy, and easy use and maintenance.
BJ-III disintegration time limit testerTechnical Indicators:
Hanging basket Number: 3
Number of glass tubes in the suspended basket: 6
Flat bottomed beaker capacity:1000ml
Round trip frequency of the suspended basket: 30-32 times/minute
Round trip trip of the suspended basket:55±1mm
2.0mm (Attachment 0.425mm)
Timed alarm range:1 minute~9 hours 59 minutes, any
Automatic temperature control accuracy:±0.5℃
Temperature preset range:20℃~45℃
heat Device power:500 W
Power supply: 220V/50HZ/600W
Dimensions: (540 * 320 * 440) mm ³

Before leaving the factory, our company has conducted strict testing on the instrument at standard room temperature using a precision temperature measuring instrument, and it has met the requirements of the Pharmacopoeia of the People's Republic of ChinaAccording to the 2010 regulations, it is recommended that users generally do not adjust the temperature themselves. If the user has temperature detection conditions and needs to adjust the temperature of the water bath in the measuring cup.
Precautions:
Correct usage and proper maintenance can help extend the service life of the instrument. Please follow the instructions in the user manual.
When the power supply voltage in the working environment is unstable, please install a voltage regulator; Please pay special attention to the regulations on power supply, temperature, and humidity in the user manual and maintain the instrument properly; The power supply should be reliably grounded.
Instruments and environment should be kept clean regularly. Do not dismantle the components or move the internal parts of the instrument at will.
If any abnormal situation occurs with the instrument, please do not continue to use it. Notify the dealer or our company as soon as possible, and inform them of the instrument model, factory number, and fault symptoms.