E-mail
bling@buybm.com
-
Phone
13761038296
-
Address
5th Floor, Building C7, Chuangyan Intelligent Manufacturing, Lane 456, Dieqiao Road, Pudong New Area, Shanghai
Shanghai Boxun Instrument Technology Co., Ltd
bling@buybm.com
13761038296
5th Floor, Building C7, Chuangyan Intelligent Manufacturing, Lane 456, Dieqiao Road, Pudong New Area, Shanghai
Core strengths——Dual device collaboration to solve scientific research problemsWeak light high-resolution dual blessingHigh precision grating monochromator (C-T structure+toroidal calibration, stray light ≤ 1 × 10)⁻⁶)Accurately separate spectra, paired with deep cooling backPhotographic CMOS camera (92% peak quantum efficiency, 0.9 e)⁻Low readout noise, long exposure for 60 minutes without interference, easy captureWeak transient signals such as chemiluminescence and fluorescence.
Wide band full coverageThe monochromator covers 200-1100nm (expandable to 1700nm) and supports the selection of multiple gratings ranging from 150-2400 g/mm; Camera adaptationHigh sensitivity detection of 400-1000nm, the system covers UV-VIS-NIR as a whole, meeting the needs of cross band scientific research.
Low noise accurate quantificationCamera dark current<0.0005 e⁻/P/S (reaching the level of cryogenic CCD)+DPC bad spot correction, combined with a monochromator as low as 0.015nmThe wavelength repeatability is improved to eliminate data bias and adapt to high-precision experiments such as quantum efficiency measurement and trace pollutant quantification.Flexible integration and easy connectivity Realize the connection and operation of cross brand spectrometers and research cameras without the need to switch between different software, and build a fully compatible brand in the futureA super platform that allows unrestricted integration of connections between different devices from various brands.
SPECTRALMIND
SPECTRALMIND is a product developed by our company that canSeamless integration and linkage of intelligent spectrometers and cameras from different brandsCapable of software. At present, we have successfully connected numerous well-known companiesSpectrometers and cameras make cross device collaboration possibleSimple. In the future, we will expand to the entire brand and strive toBecoming a universal operating platform for spectroscopic research.






Spectrometer(@1200g/mm grating | |
Focal length(mm) |
320 |
Relative aperture |
F/4.2 |
optical structure |
C-T |
Scanning step distance(nm) |
0.005 |
stray light |
1X10-5 |
Focal plane(mm) |
30 (w)X14(h) |
Optical axis height(mm) |
146 |
Grating specifications(mm) |
68X68 |
Spectrometer emits full angle |
12.5° |
Grating stage |
Triple grating |
Slit specifications |
Seam width0.01-3mm continuously adjustable manually, with optional automatic slit. Seam height:2. 4. 14mm optional |
External dimensions(mm) |
420X295X232 |
Weight(Kg) |
16 |
power consumption |
peak100W@24V |
communication interface |
standard configurationUSB2.0,RS-232 |
Grating(g/mm) |
2400 |
1800 |
1200 |
600 |
300 |
150 |
75 |
|
|
Inverted dispersion(nm/mm) @435.83nm |
0.91 |
1.39 |
2.29 |
4.87 |
9.97 |
20.13 |
40.43 |
|
Mechanical scanning range(nm) |
0-600 |
0-800 |
0-1200 |
0-2400 |
0-4800 |
0-9600 |
0-19200 |
|
Scanning step distance(nm) |
0.0025 |
0.0035 |
0.005 |
0.01 |
0.02 |
0.04 |
0.08 |
|
Narrow slit spectral resolution(nm) |
10µm |
0.05 |
0.07 |
0.08 |
0.16 |
0.32 |
0.64 |
—— |
100µm |
—— |
—— |
0.23 |
0.46 |
0.92 |
1.84 |
3.7 |
|
|
Spectral resolution(nm) @CCD(15µm) |
0.069 |
0.105 |
0.173 |
0.368 |
0.754 |
1.52 |
3.05 |
|
|
CCDSingle shot spectrum range (nm@30mmCCD) |
27.6 |
41.7 |
68.7 |
146.1 |
299.1 |
603.9 |
1212.9 |
|
Wavelength accuracy(nm) |
±0.1 |
±0.15 |
±0.2 |
±0.4 |
±0.8 |
±1.6 |
±3.2 |
|
Wavelength repeatability(nm) |
0.015 |
0.02 |
0.025 |
0.05 |
0.1 |
0.4 |
0.8 |
|
camera | |
Chip type |
BSI CMOS |
Chip model |
SONY IMX571BLR-J |
Color/Black and White |
black and white |
Diagonal dimension |
28.3 mm(1.8') |
effective area |
23.4 mm × 15.6 mm |
pixel size |
3.76 μm × 3.76 μm |
resolution |
6244 x 4168 |
dark current |
<0.0005 e-/p/s |
bit depth |
16 bit |
gain mode |
Gain0- High Full Well; Gain 1- Balance; Gain2- Sensitivity |
Full trap capacity |
50 ke-@Gain 0; 15 ke-@Gain 1; 3 ke-@Gain2 |
read mode |
Standard, Low-Noise |
|
read noise (Standard reading) |
3.2 e-@Gain 0; 1.2 e-@Gain 1; 1.0 e-@Gain 2 |
frame rate |
6.5 fps |
shutter type |
roller blind |
exposure time |
34.7 μs ~ 60 min |
image correction |
DPC |
ROI |
support |
Binning |
2×2, 3×3, 4×4, 5×5, 6×6, 8×8, 16×16 |
refrigeration temperature |
-25 ℃ @ room temperature (22 ℃) |
Trigger output |
Exposure start, global, readout end High level, low level |
Trigger interface |
Horise |
SDK |
C, C++, C# |
data interface |
USB 3.0 |
power supply |
12V/6A |
Operating environment |
Temperature 0~40 ℃, humidity 10~85% |
storage environment |
Temperature -10~60 ℃, humidity 0~85% |
Camera size |
85 mm × 85 mm × 95 mm |
ØTypical Applications
²Ramanspectral analysis:According to the wavelength of light generated by inelastic scattering,Analyze the distribution and concentration of different substances in the sample,Obtain Raman spectra
²Biological fluorescence imaging:92% quantum efficiency camera+low stray light monochromator, eliminates background interference, identifies biomarkers
²stressdetection:By irradiating the sample with laser, the Raman peak shift caused by inelastic scattering is detected. Detect the residual stress of silicon piezoresistive chips and sensors after chip packaging during the packaging process, and perform sample testingmapping, Obtain stress distribution map