●Double tube detection, capable of producing parallel samples
●Automatic liquid level tracking system (using imported sensors)
●Zero point self calibration
●Automatic fire extinguishing protection device (built-in flame detection module, automatically turns on the fire extinguishing gas source)
●Automatic discrimination of dry spots (consistent with human judgment without lag)
●Intelligent lifting platform for furnace frame (no need for manual lifting)
●Fault diagnosis reminder function
●Built in pressure sensor, automatically corrects temperature value (to avoid the influence of atmospheric pressure on temperature value)
●Using two types of control: microcontroller and computer
●Fully automatic control, one click operation to complete the experiment
●Five ending methods: final boiling point, temperature, initial boiling point, dry point, and volume ending method
●Self check and calibrate the system to make the operation more reliable
●Equipped with simulation display function: real-time display of heating power, steam temperature, cold bath temperature, cold trap temperature, and recovery volume
●Correction function: It can calibrate atmospheric pressure, vapor temperature, sensors, and measurements
●Data recording methods: temperature volume, volume temperature, temperature mass, volume mass
●Windows operating system, supports OTA upgrade
●Real time display of temperature rise curve, allowing viewing of temperature volume, volume temperature, temperature mass, and volume mass at any point
●Powerful database processing capabilities, data support laboratory Lims system
●Support multi machine interconnection
●Parameters can be modified during the distillation process
●The ending condition can be selected as a single condition or a composite condition
●Display: 13.3-inch industrial grade tablet computer
●Temperature range: 0~+400 ℃, resolution: 0.1 ℃
●Volume detection range: 0~100mL, resolution 0.1mL (the liquid level tracking system is not affected by ambient light)
●Distillation rate: 2~10mL/min (adjustable)
●Temperature measuring element: PT100 (imported from Germany)
●Printing: Thermal printing
●Refrigeration method: Imported compressor refrigeration (refrigeration system, recovery chamber can quickly reach the set value, minimizing waiting time for testing)
●Cold bath constant temperature range: 0~60 ° C
●Distillation heating method: Low pressure 32VPWM control heating method
●Total power: 1.5kw
●Operating environment temperature: 5-40 ° C; relative humidity: ≤ 80%