Atomic absorption spectrophotometer (flame graphite furnace integrated) 4520G type
4520GThe Type A atomic absorption spectrophotometer uses deuterium lamp clip background technology to provide reliable assurance for element quantitative analysis. Adopting a single interface multifunctional window design reduces the difficulty of analysts' work. The graphite furnace adopts *GFTVVisual system, realizing automatic sampler system instrument addition and hydrogenation system.
Widely used in industries such as geology, metallurgy, medicine, chemical engineering, petroleum, agriculture, animal husbandry, cement, printed circuit boards, environmental protection, and commercial inspection.
Hollow cathode lamp, graphite furnace atomization system, flame atomization system, microwave digestion instrument, ultrapure water machine.
◆ Four lamp positions, six lamp positions, and eight lamp positions are optional (high-performance element lamps are optional), with automatic 3D switching, energy balance, and multiple lamp positions preheating simultaneously to save waiting time. It has deuterium lamp buckle background and self-priming buckle background functions;
◆ *The integrated design of flame atomizer and graphite furnace atomizer achieves dual modes of automatic and manual switching;
◆ Automatic optimization of memory function for instrument settings, one click completion of scanning peak searching, and energy balance;
◆ Data reports can be saved in multiple formats and printed out for easy data retrieval and comparison;
◆ The instrument software adopts a single interface multifunctional window design, making operation simpler, real-time monitoring of data changes, and supporting mainstreamWindowsOperating system, supports remote control and calibration/The English version is optional and has comprehensive quality control(QC)Function;
◆ *A reliable multiple safety protection system that automatically detects, alarms, and detects abnormal situations such as insufficient pressure, air leakage, and engine shutdown;
◆ *The graphite furnaceGFTVVisual system,CCDReal time monitoring of graphite furnace atomizers by cameras to extend the service life of graphite tubes;
◆ The automatic sampler system can achieve automatic configuration of standard curves, automatic dilution, and high-precision injection;
◆ Scalable: Hydrogen system and combined functionality.
◆ Equipped with automatic online detection function.
Atomic absorption spectrophotometer (flame graphite furnace integrated) 4520G technical specifications
wavelength range :185nm-900nm
Monochromator:Czerny-TurnerEnhanced type
Grating line density:1800item/mm
Spectral bandwidth:0nmThe0.1nmThe0.2nmThe0.4nmThe1.0nmThe2.0nmMulti level automatic switching
Wavelength accuracy: ≤±0.1nm
Wavelength repeatability: ≤±0.025nm
Baseline drift:0.003ABS/30min(Static)0.005ABS/15min(Dynamic)
Resolution: Copper lamp324.7nmWavelength,0.2nmBandwidth, half width0.2nm±±0.01nm
Detector: Hamamatsu photomultiplier tube from Japan
Element light rack: turret type fully automatic switching light rack
Flame atomization system
Detection limit:(Cu)0.006Mg/mL
Burner:0.5mm×100mmAll titanium burner
Repeatability:RSD≤0.7%
Spray: metal sheathed high-efficiency glass spray
Atomization chamber: corrosion-resistant all plastic atomization chamber
Security measures: equipped with multiple automatic security protection functions
Position adjustment: Automatic setting of appropriate height and front and rear position of flame burner
Graphite Furnace Atomization System
detection limit(Cd):1.5pgPrecision: ≤3%Heating temperature range: room temperature~3000℃
Heating and temperature control method Power control method for drying and ashing stage, and high-power light control method for atomization stage
Temperature control accuracy:1%Heating rate:2000℃/second
Heating condition setting: 11Step, slope heating, step heating, high-power heating, temperature monitoring and reverse measurement system
Security protection: Fault protection for air pressure system and cooling system, achieving power monitoring
Deuterium lamp background correction:1ABSTime ≥60times Self suction background correction:1ABSTime ≥60times
data processing
Measurement method: Air-Acetylene flame method, graphite furnace method
Data processing: Linear regression method automatically fits the working curve and calculates the results automatically
Repeated measurement times:1~99Repeat the measurement to calculate the average value, and automatically provide the standard deviation and relative standard deviation
Result output: Multi format data saving and printing output
Communication interface: standardRS232,USBextended interface
Automatic sampler system: optional85Automatic sampler. Automatic configuration of standard curve, automatic dilution, high-precision injection
Visualization system: optionalGFTVVisual system, graphite furnace video capture system
Function expansion: Hydrogen system