Anti corrosion magnetic flap level gauge without blind spots

NegotiableUpdate on 12/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Beijing Tongda Zhichuang specializes in producing various magnetic flap level gauges. The non blind spot anti-corrosion (PTFE lined) magnetic float level gauge is suitable for level measurement in corrosive media and high operating temperatures. Due to the use of advanced stainless steel lined PTFE stretching and flanging technology, the liquid level gauge has no blind spots in measurement, reliable structure, and superior anti-corrosion performance. The float material is made of stainless steel coated with fluorine or PTFE, or glass float, which has better structural strength and corrosion resistance. Suitable for acidic and alkaline liquids such as hydrochloric acid, as well as many organic solvents.

Product Details

Non blind spot anti-corrosion type(PTFE lined type)Magnetic float level gauges are suitable for measuring liquid levels in corrosive media and high operating temperatures. Due to the use of advanced stainless steel lined PTFE stretching and flanging technology, the liquid level gauge has no blind spots in measurement, reliable structure, and superior anti-corrosion performance. The float material is made of stainless steel coated with fluorine or PTFE, or glass float, which has better structural strength and corrosion resistance. Suitable for acidic and alkaline liquids such as hydrochloric acid, as well as many organic solvents.

Measurement range:2006000mm
Measurement accuracy:±10mm

work pressure≤ 2.5Mpa
Temperature range:-160℃~200℃
Material of the cavity: Stainless steel lined with PTFE
Float material: stainless steel outer layer coated with fluorine or PTFE
Medium specific gravity:≥0.45g/cm3
Medium density difference:≥0.15g/c m3(Measurement boundary)
Medium viscosity:≤0.02Pa. S
Transmission output signal: two-wire system 420mADC 250Ωload
Connection flange size:DN20/DN25 ,PN2.5HG 20592-97
If other flanges are used, please indicate when placing an order.

TDZC-UHZ-F

Non blind spot anti-corrosion type

L

drain valve

1.UK-1magnetic switch
2.UK-2Bidirectional holding type magnetic switch

R

UQZ-10 4-20mATwo wire transmitter

D

Isolated type

E

intrinsically safe

F

Equipped with isolation safety barriers

A

XMGLight column digital display meter(1)Horizontal style(2)Vertical style

J1

Steam heating jacket type

J2

Circulating water heating jacket

J3

Vacuum jacket

J4

electric heat tracing device

-□

measurement range

-□

medium density

-□

work pressure