TECTITE Express 5.0Air tightness testing system testing software for blast doors

WiFi is an international building air tightness testing and analysis program developed by The Energy Conservatory for PC computers. This program is easier than ever to perform fully automatic drum damper testing, as well as analyze and store drum damper test data. The built-in report generator and graphical features of this program allow you to easily record and display the results of hair dryer door testing to homeowners or customers.
TECTITE Express 5.0Air tightness testing system testing software for blast doorsCharacteristics of WiFi


Specially designed for use with Minneapolis blower systems.
Easily input all test settings and building information, and quickly generate reports.
Calculate and display the results of building airtightness testing, including CFM50, hourly air exchange rate, leakage area, and building leakage curve.
The manual data input mode allows you to easily input manually collected test data.
The automatic testing function provides computer control of the blower door fan and automatic flow and pressure measurement. Reduce operator errors, eliminate zero time, and ensure that testing is conducted in the same way every time.
The 'pause function' allows automated testing to temporarily pause and then restart at the pause point.
The semi-automatic testing option allows for the collection of computer data while manually controlling the blower door fan.
Measure, record, and report up to 6 additional building area pressures during automatic air damper testing (multiple DG-700 pressure gauges or APT systems can be used).
Deviation from standard reporting function.
Data point deletion option.
Real time air exchange rate calculated at 50 Pa (ACH50) per hour during cruise control. Screen display helps to quickly estimate the leakage rate of buildings before conducting comprehensive testing.
The program help screen makes the program operation very user-friendly.
WiFi connection used for automatic testing when using DG-1000 or DG-700 in conjunction with TEC WiFi Link.
Built in PDF file report generator.
Four airtightness testing standards are available for selection: ASTM E779-10, CGSB 149.10-M86, EN 13829, and ISO 9972-15.
Pressure and pressure tests can be combined in the same test file.