- Phone
-
Address
Building 1, No. 5 High tech Fifth Street, Huilongguan, Changping District, Beijing
Beijing Hemu Technology Co., Ltd
Building 1, No. 5 High tech Fifth Street, Huilongguan, Changping District, Beijing
1、 Standard
TD-25typehotsolutionanalyzeceremonyis used forairVolatile organic compounds in the sample(Detection of VOCs, enrichment and preparation of volatile organic compounds in air samplesofThe product meets the following standards for pyrolysisanalyzeRequirements for the instrument:
1. GB 50325-2020 Code for Indoor Environmental Pollution Control of Civil Building Engineering
2. GB 18883-2022 Indoor Air Quality Standards
3. HJ 583-2010 Determination of Benzene Compounds in Environmental Air Solid Adsorption/Thermal Desorption Gas Chromatography Method
4. HJ 734-2014 Determination of volatile organic compounds in fixed source exhaust gas Solid phase adsorption thermal desorption/gas chromatography-mass spectrometry method
5. HJ 644-2013 Determination of volatile organic compounds in ambient air - Adsorption tube sampling thermal desorption/gas chromatography-mass spectrometry method
6、《HJ/T400-2007 Volatile Organic Compounds and Aldehydes in CarsMethods for Sampling and Determining Ketone Substances, etc.
IIInstrument features and main functions
1. Equipped with leak detection function, a tightness test must be conducted before each program run to ensure that the sample is not lost during analysis and to guarantee the recovery rate;
2. Equipped with dry blowing function, the sampling tube is automatically dried and removed during each analysisAnalysis tubeOxygen and water vapor in the middle to ensure peak effect and avoid separationDamage caused by analytical instruments (especiallyGC-MSFilament);
3Analysis tubeHeating、pipeline、Six way valve, etcThe heating temperature can be independently set;The sample flow path must be an inert pipeline that has undergone silane treatment to avoid residuemakeCross contamination;
4. Equipped with aging function, it automatically analyzes after each analysisAnalysis tubeAging is carried out to ensure that there is no residue in the sample tube after each analysis, and it can be directly sampled outside;
5Using touch screen editing, saving, and calling methodsIt can automatically save multiple experimental methods, making it more convenient to use.
6. Through time programming, it is possible toDynamic implementationDry blowingDesorption, injection, blowback、wash(activation)Other functions;
7. Adopting semiconductor refrigeration, high cooling efficiency, no need for external refrigeration devices, saving usage costs;
8The cold trap focusing tube adopts ultra-low adsorption quartz tube with the smallest inner diameter≤ 0.9mm (in accordance with HJ644 requirements);
9adoptSimplee-LocK Locksealtechnical implementationAnalysis tubesimple and convenientreliableFixed and sealed,Completed in 2 secondsAnalysis tubeThe fixation and disassembly achieve efficient work efficiency;
10Equipped with analog sampling device as standard,It can be more conveniently achieved through pyrolysisanalyzeInstrument production work curve;
11、Can work with any brand both domestically and internationallyThe combination of GC/GC-MS can be used in series without occupying the injection port, or in parallel with the analytical instrument that can be replaced in just a few seconds; You can freely choose according to the usage environment.
IIIMain technical parameters of the instrument
1. Sample size: 25 digits;
2. Analysis tubeTemperature control range: room temperature400℃、precision1℃;
3Temperature control range of valve injection system: room temperature220℃、precision1℃;
4Temperature control range of sample transfer pipeline: room temperature260℃、precision1℃;
5secondary parsingUsing quartz focusing tube, small adsorption, no cross contamination, minimum inner diameter0.9mm,Temperature range:-35℃400℃, Secondary flash evaporation heating rate:>3000℃/min
6Desorption recovery rate:>98% (related to components);
7Backblowing cleaning flow rate:0~100ml/min (continuously adjustable);
8Simulated sampling flow rate:0100ml/min;
fourConfiguration List
1TD-25typehotsolutionanalyzeceremony1 host;
2. Tenax TA (60/80) mesh stainless steel heat analysis tube, 2 pieces of 1/4 inch * 3.5 inch;
3Simplee-LocK LockSealed injection system 1 set;
4. One dedicated adapter bracket for gas phase injection port;
5. One set of standard sample simulation sampling device;