AO2000 series continuous gas analyzer
The modular analyzer product series has the following characteristics, which can bring you many benefits:
A central unit and various analyzer modules
- Support universal control
- Support the same connection technology
- Use a unified system shell
All analyzers use high-performance measurement techniques and simplified calibration, without the need for test gas cylinders.
- photometer
In situ laser analyzer
- Oxygen analyzer
-Trace oxygen analyzer
Thermal conductivity analyzer
- FID analyzer
● Multi analyzer system: up to four analyzer modules and up to six sample components in one system
● Achieve large-scale automatic calibration through air calibration or integrated calibration room, without the need for standard gas cylinders
The self check function indicates when maintenance is needed
The approved models for hazardous sites comply with ATEX and GOST-R, 2G, 3G categories, and CSA Class I, Division 2
Safety concept for measuring yr gas in Zone 2, 3G category
● Provide Ethernet TCP/IP interface, OPC server, PROFIBUS and Modbus interface
AO2000 series continuous gas analyzerChassis:
The chassis is divided into 19 inch or wall mounted, supporting IP20 or IP54 protection levels (the version used for emission measurement is IP40).
IP54 version chassis supports blowing.
When installing electronic modules, the display and control unit are located on the front panel of the chassis.
System bus:
The functional units of the gas analyzer are interconnected through a system bus.
The system bus structure is linear, with a maximum length of 350 meters.
The system bus structure can only connect one electronic module with a maximum of 5 I/O modules.
Connection of sample gas regulation module:
The SCC-F sample gas extraction unit and SCC-C sample gas condenser are connected to the gas analyzer through a system bus via a 1/O board installed on the sample gas extraction unit.
In this way, the display, monitoring, and control of various sample gas adjustment functions of the gas analyzer can be achieved, such as condenser temperature, condensate, and flow status.
For more information, please refer to the "Sample Gas Preprocessing System Components and Accessories" data manual.
Technical parameters of all modules and components of the Advance Optima AO2000 series modular products
Configuration of analysis units and multi-component analysis systems
Example 1: Analyzing Unit Configuration (19 inch Chassis)

Example 2: Multi component analyzer system (wall mounted chassis)

Application scenarios (for more application details, please contact sales)
type |
name |
Sample gas (example) |
application |
photometer | |||
Infrared photometer |
Uras26 |
CO、CO2、NO、SO2、N2O、CH4、C2H6、C2H4(Up to 4 types) |
Emission monitoring, combustion control, landfill, natural gas production, fermentation tanks, process monitoring |
Process photometer |
Limas11IR |
CO、CO2、HCl、CH4、C2H2、C2H4、C₂H6(Up to 5 types) |
Purity and emission monitoring of exhaust gas and chemical industry |
Process photometer |
Limas21UV |
NO,SO2,NO2,H2S,Cl2,COS |
Cl ₂, cellulose PVc/VCM、 Sulfuric acid, hydrochloric acid |
Process photometer |
Limas21HW |
NO,NO2,NH3 |
Nitric acid, diesel engines, off sales, catalysts |
In situ laser | |||
Near infrared laser |
LS25 |
O2,CO,HCI,HF,NH3… |
Petrochemical, combustion control, inventory, glass and steel |
oxygen analyzer | |||
Magnetic mechanical |
Magnos206 |
O2 |
Air fractionation, biochemical plants, purity CEM |
thermomagnetic |
Magnos27 |
O2 |
Smoke analysis, roasting furnace, cement smoke |
thermal conductivity |
|||
Silicon sensor |
Caldos27 |
Argon mixed with O2、H2Mixing argon gas, H2Mixing with N2air |
Hydrogen purity, turbine generator, inert gas monitoring, UEL/LEL monitoring |
Glass measuring tank |
Caldos25 |
H ₂ mixed with Cl ₂, SO ₂ mixed with N ₂/air, H ₂ mixed with N ₂/air |
Sulfur dioxide and ammonia decomposition in chlorine production and smelting flue gas |
Flame ionization | |||
FID probe |
MultiFID14 |
hydrocarbon |
Volatile organic compounds, emission monitoring, automotive industry, ambient air, process control |
Infrared analysis module Uras26
Measuring principle
Non dispersive infrared absorption in the wavelength range of λ=2.5-8 μ m.
The photometer can be configured with 1 or 2 optical paths for measuring 1-4 components, and each optical path can be configured with 1 or 2 detectors.
Sample gas composition and range
The Uras26 analysis module has a physical range for each sample gas component. Alternatively, a smaller range can be selected electronically from the physical range.
The minimum range is range 1.
The minimum range shown in the table is based on the first sample gas component in optical path 1.
Sample gas components |
Minimum Level 1 Range |
Minimum Level 2 Range |
Minimum 2-level range, with calibration pool |
Gas group1) |
CO |
0-50 ppm |
0-10 ppm |
0-50 ppm2) |
A |
CO2 |
0-50 ppm |
0-5 ppm |
0-25 ppm2) |
A |
NO |
0-75 ppm |
0-75 ppm |
0-75 ppm2) |
A |
SO2 |
0-100 ppm |
0-25 ppm |
0-25 ppm2) |
A |
N2O |
0-50 ppm |
0-20 ppm |
0-50 ppm2) |
A |
CH4 |
0-100 ppm |
0-50 ppm |
0-50 ppm2) |
A |
NH3 |
0-500 ppm |
0-30 ppm |
- |
B |
C2H2 |
0-200 ppm |
0-100 ppm |
0-100 ppm |
B |
C2H4 |
0-500 ppm |
0-300 ppm |
0-300 ppm |
B |
C2H6 |
0-100 ppm |
0-50 ppm |
0-50 ppm2) |
B |
C3H6 |
0-250 ppm |
0-100 ppm |
0-100 ppm2) |
B |
C3H8 |
0-100 ppm |
0-50 ppm |
0-50 ppm2) |
B |
C4H10 |
0-100 ppm |
0-50 ppm |
0-50 ppm2) |
B |
C6H14 |
0-500 ppm |
0-100 ppm |
0-100 ppm2) |
B |
R134a |
0-100 ppm |
0-50 ppm |
0-50 ppm2) |
B |
SF₆ |
0-5 ppm |
0-4 ppm |
- |
B |
H2O |
0-1000 ppm |
0-500 ppm |
0-500 ppm |
C |
Note:
1) See price information
2) Minimum range 1 has been provided. The maximum range should be at least 4 times or more. Other sample gas components can be provided according to demand.
Number of measurement ranges
1-4 ranges for each sample gas component
maximum range
0-100 vol.%, Or 0 vol.% to saturation, or 0 vol.% to LEL. Cannot provide a range within the combustion limit.
turndown ratio
≤ 1:20
Zero suppression range
Electronic zero suppression or differential measurement (flowing reference gas)>0, with a maximum suppression ratio of 1:10
stability
The following data is constant based on all influencing factors such as flow rate, temperature, and atmospheric pressure. They are applicable to the range 1 in the delivered analysis module.
Linear deviation
≤ 1% range
Option: Linearization can be performed according to EPA specifications for automotive exhaust measurement
repetitiveness
≤ 0.5% range
zero drift
≤ 1% range/week;
Range less than level 1 to level 2: ≤ 3% range/week
Span Drift
≤ 1% measured value per week
Output fluctuation (2 σ)
≤ 0.2% range, electronic T90Time=5 seconds (Level 1 range) or 15 seconds (Level 2 range)
Detection limit (4 σ)
≤ 0.4% range, electronic T90Time=5 seconds (Level 1 range) or 15 seconds (Level 2 range)
influencing factors
Traffic impact
Flow within the range of 20-100I/h: within the detection limit
Background gas influence/cross sensitivity
The calibration of the analyzer should be based on the analysis of the components of the sample gas.
Selective measures can be taken to reduce the influence of background gas (optional): When using Uras26 to measure one sample gas component, interference from other sample gas components can be minimized,
It can be achieved by adding filtersCorrection of filter, internal electronic cross interference correction, or carrier gas correction functions.
temperature effect
The ambient temperature is within the allowable range
-Zero point: ≤ 1% range/10 ° C
Less than Level 1 to Level 2 range: ≤ 2% range/10 ° C
-Sensitivity during temperature compensation: ≤ 3% measured value/10 ° C
-Sensitivity when configuring a 55 ° C thermostat (optional): ≤ 1% measured value/10 ° C
Air pressure influence
-Zero point: No impact
-Sensitivity for pressure calibration through integrated pressure sensors: ≤ 0.2% measured value/1% change in air pressure
If a hose is used as the internal gas pipeline, the pressure sensor is located in the sample gas path.
If a hard tube is used, the pressure sensor is connected to the outside through a hose.
power influence
DC 24V ± 5%: ≤ 0.2% range
dynamic response
warm-up time
If there is no thermostat, it takes about 30 minutes; If a thermostat is used, it takes about 2 hours.
T90response time
T90=2.5 seconds, when the measuring cell length is 200mm, the sample gas flow rate is 60 l/h, and there is no signal attenuation (low-pass filter).
The low-pass time constant supports adjustment between 0-60 seconds.
calibration
zero point calibration
Use inert gas (such as nitrogen) or ambient air that does not contain the components of the sample gas being tested.
Range calibration
Use the built-in inflatable regulating pool (option) or standard gas. If a built-in regulating pool is configured, it is recommended to verify its set value annually.
When calibrating a multi-component analyzer, the internal or external cross sensitivity and/or carrier gas calibration functions for the measured components will be turned off. Therefore, when calibrating the corrected tested components,
Only standard gases containing the tested component and inert gases (such as nitrogen) can be used.
※ If you want to learn more product information, you can contact our sales team to select and recommend products according to your needs