Welcome Customer !

Membership

Help

Shanghai Aoxi Scientific Instrument Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Shanghai Aoxi Scientific Instrument Co., Ltd

  • E-mail

  • Phone

  • Address

    3rd Floor, Building 1, No. 552 Liancao Road, Minhang District

Contact Now

AFS120 02 Atomic Fluorescence Spectrophotometer

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The AFS120 02 atomic fluorescence spectrophotometer is a fully automatic intermittent pump injection dual channel type used for trace element analysis. The dual channels can simultaneously measure two elements and automatically adjust the energy ratio of the dual cathode lamps to improve the stability of the measured elements while significantly reducing memory effects. Fully automatic control, convenient, fast, and accurate.

Product Details

AFS12002Atomic fluorescence spectrophotometer

  • Introduction

AFS-12002The upgraded fully automatic intermittent pump injection dual channel atomic fluorescence spectrometer is used for trace element analysis. The dual channels can simultaneously determine two elements and automatically adjust the energy ratio of the dual cathode lamps to improve the stability of the measured elements while significantly reducing memory effects. Fully automatic control, convenient, fast, and accurate.

  • application field

Widely used in food hygiene monitoring, environmental sample testing, urban water supply and drainage testing, agricultural product testing, fishery and marine sample testing, geological and metallurgical testing, cosmetics testing, drug testing, soil, feed and fertilizer testing, and clinical medical testingAsTheSbTheBiTheHgTheSeTheTeTheSnTheGeThePbTheZnTheCdTheAuTrace analysis of elements.

AFS120 02 Atomic Fluorescence SpectrophotometerPerformance characteristics

Measurement method

Dual channel, single element testing, dual element simultaneous testing optional, dual element simultaneous measurement, improves instrument analysis speed.

◆ Light source system

Bundle pulse power supply method, specially designed high-intensity coded hollow cathode lamp; Automatically identify single and dual cathode lamps, and automatically adjust the energy ratio of dual cathode lamps.

Atomizer

Adopting a double-layer shielded quartz atomizer and an argon hydrogen flame low-temperature automatic ignition device, the imported ignition furnace wire has a long service life and low cost, which greatly reduces the memory effect while improving the stability of the measured element.

◆ Light metering system

Adopting a high signal-to-noise ratio photoelectric detection system and a non dispersive fully enclosed light path system with short focal length lens focusing.

◆ Gas liquid separator

Chemical gas-phase gas-liquid separation device, where reactants are fully mixed and in contact, automatically removes a large number of bubbles generated by complex organic components in the body sample online; Secondary gas-liquid separator: equipped with a device for removing water vapor, effectively eliminating water vapor.

◆ Harmful element capture trap device for recovering residual contaminated elements

We use a harmful element capture trap device in atomic fluorescence analysis to recover residual pollutants in the environment (such as arsenic, lead, etc.), especially for the recovery of mercury vapor. It not only avoids secondary pollution in the laboratory but also further protects the safety of instrument operators.

◆ Equipped with automatic online detection function

  • Upgrade function

The pre-processing module for configuration form analysis can be usedAsTheHgTheSeTheSbMorphological analysis (and can)AsTheSbForm can be analyzed simultaneously);

Reserved fixed injection cadmium detection device interface, which can directly detect cadmium in solid and liquid samples. (Relevant device models and color page evidence are required).

Reserved interface for solid injection mercury detection device, which can directly detect mercury in solid and liquid samples.

◆ Function *Windows 7/XPChinese and English software workstations. Save expert assistance system and recommend instruments.

  • Technical specifications

1.detection limit(D.L.):AsTheSeThePbTheSnTheTeTheBiTheSb < 0.01 µg/L;HgTheCd <0.001µg/L;Ge <0.05µg/L;Zn <1.0µg/LAccuracy(RSD): <0.8%.

2.Linear range of three to four orders of magnitude; (Actual measurement data curve is required)

3.Can be measured simultaneously in two channels, used forAsTheSbTheBiTheHgTheZnTheCdTrace analysis of eleven elements;

4.Using coded hollow cathode lamp technology, the software automatically identifies the type of hollow cathode lamp;

5.The newly designed mechanical mechanism is more compact, using the same reference optical plane to achieve better coincidence between the center of the atomizer and the optical focal point;

6.Adopting a separated chemical reaction system, the hydride reaction is uniform and the gas water separation effect is better;

7.Automatic diagnosis and detection upon startup, automatic setting of lamp current and air flow rate;

8.Power on self-test, automatic air circuit control, automatic protection, and automatic alarm;

9.Double layer shielded quartz atomizer, automatically ignites argon-Hydrogen flame;

10.The electromagnetic valve island automatically controls the gas path, making the gas flow rate more stable;

11.Dynamic follow-up noise reduction technology improves the anti-interference ability of the instrument and avoids background interference caused by stray light;

12.New analog and digital separation circuit design effectively eliminates inter channel interference;

13.Automatic alarm for critical gas pressure to prevent backfire and explosion;

14.Upgradeable support for element morphology analysis testing.

15.A simple and efficient atomic fluorescence software workstation with * functions, supportingWindows XPTheWin 7Thewin 8operating system ;

16.Communication automatic detection and real-time connection with atomic fluorescence host;

17.Support two testing methods: peak height integration and peak area integration;

18.adoptUSB2.0Communication interface, with higher communication speed and better compatibility with computer systems;

19.Real time chart of test data, dynamic scaling of graphics, and graphics playback browsing function;

20.The graphical interface can display and hide, making it more convenient and intuitive to view data;

21Support packaging, archiving, and storage of test data, and re calling browsing functions;

  1. Personalized software interface, easy and fast operation;

autosampler

1.The robotic arm of the powered automatic sampler automatically resets to zero;

2.The software automatically recognizes the automatic sampler upon startup;

3.The high-precision polar coordinate robotic arm has a displacement deviation of0.1mmWithin;

4.Rotary array160Sample tray, using standard10mL(1-158Position),30ml(159.160Sample tube;

5.Large capacity flow channel, small hole low diffusion cleaning position, effectively eliminating contamination of the current by residual sampling needles and cross contamination between samples;

6.Reset the zero point of the cleaning position coordinates, with a small degree of accumulated error in movement;

7.3Independently control the optocoupler of each motor to shorten the sampling time;

8.Smooth operation, fast and accurate, low noise, no sample dripping phenomenon;

9.Upgradeable installation of UV online digestion device.

System Requirements

1Atomic Fluorescence Host 1set

2Automatic sampler 1set

3Hollow core cathode lamp 2Branches (arsenic, mercury)

4Atomic Fluorescence Workstation Software 1set

5Software encryption 1a

6Commercial brand computers and printers 1Set (non-standard configuration)

7The(IntelCorei7,4GMemory,1TBHard drive, discrete graphics card,DVDCD drive,20Inch LCD display,RS232-USBTransfer data cable)