991-003014-599 Overseas Arrival PARKER Micro Valve from the United States

NegotiableUpdate on 05/13
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

991-003014-599 Parker miniature valve from abroad arrived in the United States. Advantages of selecting Parker miniature solenoid valve $r $n Material and process: precision assembly in the United States, longer FKM seal life, and anti-aging valve body. $r $n pressure resistance and stability: 6.9 bar high pressure design, suitable for industrial pneumatic, medical equipment, and analytical instruments. $r $n ultra-low leakage: helium detection grade seal, suitable for vacuum/low-pressure precision control scenarios.

Product Details

Dongguan Guanglian Automation Technology Co., Ltd. is a comprehensive trading company that sells European and American automation products. It is mainly responsible for the purchase of European and American brands, mainly serving the Chinese Mainland market. In order to help customers save more time, manpower and material costs, we will purchase directly from the place of origin to supply customers. Under the premise of ensuring product quality, we will compete in the market with short and excellent price advantages. What we need to do is to save costs for our customers and create more wealth and value!

991-003014-599 Overseas Arrival PARKER Micro Valve from the United States

PARKER 991-003014-599 (V2 series miniature solenoid valve)

Model meaning: 991=V2 series; 0030=Specification; 14=DC24V; 599=Sealing/Interface Configuration.

1、 Core parameters

Structure: 3/2-way, normally closed (NC), direct acting, spring reset

Voltage: DC24V (± 10%, 20-28V)

Pressure: Vacuum~6.9 bar (100psi) (higher than 991-000211-013 high-pressure model)

Interface: 1/8 "NPT internal thread

Flow rate: ≈ 35 SLPM (Δ P=5bar)

Material: PBT valve body, FKM seal (oil resistant/medium temperature)

Response: ≤ 30ms; lifespan: ≥ 25 million cycles

2、 Installation precautions (key points)

Flow direction and installation posture

The valve body arrow must be in the same direction as the airflow, reverse installation may cause internal leakage/poor closure.

Prioritize the coil facing vertically upwards to reduce impurity deposition; Can be viewed from any angle, but avoid long-term inversion.

Gas source and medium

Medium: clean, dry, oil-free air/inert gas; Prohibit water, oil, dust, and welding slag.

The front end must be equipped with a 5 μ m filter, and high-pressure models require anti particle clogging of the valve core.

electrical wiring

DC24V, No distinction between positive and negative poles (no freewheeling diode).

Avoid 100% long-term power on (poor heat dissipation of micro coils, recommended ≤ 80% ED).

Environment and Pressure

Environment: 0-50 ℃, moisture-proof and dustproof, away from heat sources/vibrations.

Pressure: It is strictly prohibited to exceed 6.9 bar; Low starting pressure ≥ 0.5bar.

3、 Common fault diagnosis (quick troubleshooting)

1) No action when powered on (no "click" sound)

Electrical (most common): voltage<20V or>28V; coil open circuit (∞)/short circuit (≈ 0 Ω, normal about 100-200 Ω); Loose wiring.

Mechanical: valve core stuck (impurities); Spring fracture/fatigue.

Judgment: Measure voltage → Measure resistance → Power off and manually press the valve core (lagging=mechanical problem).

2) There is sound when powered on, but no direction change/air leakage

Half stuck valve core, aging/deformation of FKM seal, impurities in valve seat, and leakage of interface threads.

Judgment: whether the ventilation listening port is always open; After cleaning the valve seat, retest and if there is still leakage, replace the seal.

3) Coil overheating/burning (hot to the touch)

Long term overpressure, stuck valve core leading to coil overload, high voltage, and poor heat dissipation in the environment.

Judgment: Hot hands+valve not functioning → 90% valve core stuck.

4) Slow response/sometimes good and sometimes bad

The gas source contains water/oil, the valve core is slightly stuck, the wiring is loose, and it is affected by vibration.

Judgment: Related to pressure fluctuations → Gas source issue; Related to vibration → wiring issues.

4、 Maintenance points (extending lifespan)

Regular: Clean the filter and drain every quarter; Clean the valve core/seat annually and inspect the seals.

Prohibition: Disassemble and mix parts (with high fitting accuracy); Lubricate with mineral oil (corroding FKM seals).

5、 Compared with 991-000211-013

991-003014-599:1/8 "thread, high pressure 100psi, FKM seal, suitable for medium pressure pneumatic.

991-000211-013:4mm quick insert, low pressure 15psi, PTFE seal, suitable for vacuum/low pressure.