- Phone
-
Address
Baoding National High tech Industrial Development Zone
Baoding Lange Constant Flow Pump Co., Ltd
Baoding National High tech Industrial Development Zone
Adopting brushless servo motor, the drive and motor are integrated, and the maximum flow rate can reach 11L/min
Support position control mode, control the absolute rotation angle of the motor through pulse signals
Support speed control mode, control the pump speed through 4-20mA/0-5V analog signal, pulse frequency signal, or communication command (RS485 interface, Modbus RTU protocol)
Equipped with a 17 bit absolute value encoder for closed-loop feedback, it accurately controls the operation of the motor and outputs real-time speed and fault alarms to assist in the closed-loop automation control process
| parameter | 80 series |
| Motor type | Brushless servo motor |
| Does it include a control board | contain |
| Maximum reference flow rate (single channel) | 11000mL/min |
| Including pump head model | nothing |
| speed range | 0-600rpm |
| speed control | RS485, 4-20mA, 0-5V, 0-5V, 0-10kHz (depending on product model) |
| control function | Position control mode, speed control mode (depending on product model) |
| Overall dimensions | 198mm*130mm*138mm |
| Installation Method | Bottom plate installation |
| Applicable power supply | DC24V/260W |
| Working environment temperature | 0℃-40℃ |
| Working environment humidity | Humidity<80% |
Detailed specifications
| Product Model | T600-BLC04S-11 | T600-BLA04S-11 | T600-BLV04S-11 | T600-BLF04S-11 |
| speed range | 0-600rpm | |||
| Speed control accuracy | ±1rpm | |||
| Speed control resolution | 1rpm | |||
| Drive Type | Brushless servo drive, 17 bit absolute value encoder | |||
| control mode | Position control mode, speed control mode | Speed control mode | Speed control mode | Position control mode, speed control mode |
| Position control mode | Communication command controls the start stop, direction, and speed of the pump | nothing |
nothing |
Position pulse signal+direction signal, the pump rotates the corresponding angle in the specified direction |
| Speed control mode | Communication command controls the start stop, direction, and speed of the pump |
4-20mA corresponds to 0-600rpm Dry contact signal control for start stop and direction |
0-5V corresponds to 0-600rpm Dry contact signal control for start stop and direction |
0-10kHz (level 5-24V) corresponds to 0-600rpm Dry contact signal control for start stop and direction |
| Status output |
Speed output: 10Hz-6kHz corresponds to 1rpm-600rpm Fault alarm output: Level signal (default low level alarm, can be set as high level alarm) |
|||
| Communication function |
RS485 interface, Modbus RTU protocol Baud rate: 9600bps, 19200bps, 38400bps, 57600bps Checkpoint: None Mailing address: 1-127 Stop position: 1 position |
nothing | nothing | nothing |
| Power requirements | DC24V/260W | |||
| Dimensions (L * W * H) | 198mm*130mm*138mm | |||
| working environment | 0 ℃ -40 ℃, humidity<80%, no condensation, altitude<2000m | |||
Adapt pump head hose and flow rate
| Adapt pump head | Adapt hose | Maximum reference flow rate (mL/min) |
| (1,2) X KZ25-13 | 15#, 24#, 35#, 36# | 6000 (single channel) |
| KZ35-13 | 73#, 82# | 11000 |
| YZ35-13 | 73#, 82# | 11000 |
Overall Dimension Drawing

Flow Curve Chart
