80 liter CO2 incubator HH.CHP-TW water jacket heatingMain features:
1. The carbon dioxide incubator adopts a streamlined arc design, and the outer shell is made of cold-rolled steel plate with surface electrostatic spraying; The inner liner is made of stainless steel material, and the semi-circular four corner design makes cleaning more convenient.
2. Microcomputer temperature controller with small temperature fluctuations, equipped with ultraviolet sterilization lamps inside the box to regularly disinfect the box with ultraviolet radiation, preventing contamination during cell culture.
3. Double layered door structure: After the outer door is opened, the laboratory experiment is observed through the inner door made of high-strength tempered glass, and the temperature and humidity are not affected.
4. The CO2 concentration sensor adopts an imported infrared probe, which can directly display the CO2 concentration inside the box and operate reliably.
5. The independently set door heating system can effectively avoid the phenomenon of exposure on the inner door glass.
6. The studio adopts water tray natural evaporation humidification, and the humidity is directly displayed by the instrument.
7. The carbon dioxide incubator is equipped with an independent temperature limit alarm system, which automatically interrupts when the temperature limit is exceeded, ensuring the safe operation of the experiment and preventing accidents.
The function of carbon dioxide incubator
1. The carbon dioxide incubator can provide precise and stable control over temperature, carbon dioxide concentration, and humidity to facilitate the progress of its research work;
2. The carbon dioxide incubator can effectively prevent microbial contamination inside the incubator and regularly eliminate contamination to protect research results and prevent sample loss.
Carbon dioxide incubators are widely used in cell and tissue culture, as well as the cultivation of certain special microorganisms. They are commonly used in cell dynamics research, collection of mammalian cell secretions, carcinogenic or toxic effects of various physical and chemical factors, antigen research and production, cultivation of hybridoma cells to produce antibodies, in vitro fertilization (IVF), stem cells, tissue engineering, drug screening, and other research fields.
A carbon dioxide incubator is an instrument used for culturing cells, tissues, and bacteria. It is also a key equipment necessary for the development of immunology, oncology, genetics, and bioengineering. It is widely used in the research and production of microbiology, agricultural science, and medical experiments.
The water jacket carbon dioxide incubator is a biochemical experimental instrument used for cell tissue and bacterial culture. It adopts a fan assisted air jacket system, a three-dimensional heating process, and a fan placed in the inner cavity for forced circulation, so that the temperature inside the cavity reaches a highly uniform distribution in time and space, with excellent reproducibility, meeting the temperature accuracy requirements of the water jacket carbon dioxide incubator. Suitable for life sciences, immunology, genetics, clinical medicine, agricultural science, pharmacology, pharmaceutical industry, food industry, toxicology, basic biology research, and early clinical medical research.
The pressure used in water jacket carbon dioxide incubators is generally not very high, and incubators are very delicate. Therefore, it is necessary to first adjust the pressure at the outlet of the pressure reducing valve before connecting the incubator. After installing the carbon dioxide pressure reducing valve of Chuanyi Instrument on the steel cylinder, turn the main switch of the steel cylinder counterclockwise. The pressure inside the steel cylinder is displayed on the gauge on the right side of the pressure reducing valve. Observe the reading of the high-pressure gauge and record the pressure of carbon dioxide inside the high-pressure cylinder. If the pressure is very low, it indicates that the amount of carbon dioxide is small and needs to be refilled with carbon dioxide. After the pressure is normal, insert the adjusting handwheel of the pressure reducing valve that was configured at the factory into the protruding hole on the front of the pressure reducing valve. Slowly rotate the adjusting screw of the pressure reducing valve clockwise to compress the main spring and open the valve. The gauge on the left side of the pressure reducing valve displays the exhaust pressure. In this way, the high-pressure gas from the inlet enters the low-pressure. In general, the pressure required for a carbon dioxide incubator is in the range of 0.03Mpa to 0.06Mpa, and it can also be used up to 0.1Mpa, depending on the actual situation. Carefully check if there is any air leakage at the connection point, apply soap solution to the connection for inspection, adjust the connection if there are bubbles, and conduct the experiment after confirming that there is no air leakage. After use, turn off the main switch of the steel cylinder clockwise first, and then loosen the pressure reducing valve counterclockwise.

80 liter CO2 incubator HH.CHP-TW water jacket heatingTechnical Specifications
model |
HH. CHP-T |
HH. CHP-01 |
HH. CHP-TW |
HH. CHP-01W |
volume |
80L |
160L |
80L |
160L |
Heating method |
Gas sleeve type |
Water jacket type |
||
Temperature control range |
Room temperature+5~65 ℃ |
|||
temperature resolution |
0.1℃ |
|||
Constant temperature fluctuation |
±0.2℃ |
|||
CO2 control range |
0~20% |
|||
CO2 control method |
Imported infrared microcomputer CO2 concentration probe control |
|||
Humidification method |
Natural evaporation (water distribution tray) |
|||
humidity range |
Greater than 95% RH (stable operation at+37 ℃) |
|||
working hours |
1~9999 minutes or continuous |
|||
power |
400W |
500W |
850W |
1250W |
working power supply |
AC 220V 50Hz |
|||
studio dimensions |
400*400*500 |
500*500*650 |
400*400*500 |
500*500*650 |
Overall dimensions |
550*610*785 |
650*710*935 |
550*610*775 |
650*710*925 |