5.5kw single impeller high-pressure fan - single-stage high-pressure blowerCharacteristic Introduction
1. Aluminum die-casting impeller: generates stable airflow and efficient flow rate; 2. Dynamic balancing impeller: smoother operation, no vibration during operation; 3. Double covered bearings: prevent grease leakage and increase the reliability of operation; 4. Dustproof shaft seal: prevents dust intrusion and extends bearing life; 5. The combination of motor spindle and impeller inlay: without the need for connectors, belts, or gears, there is no concern of breakage or wear; 6. 50/60HZ and wide voltage design: reduces the manufacturer's inventory demand for 220V to 660V voltage; 7. High performance cooling fan: effectively cools the motor and air pump, enabling them to operate efficiently and with low noise; 8. Embedded thermal protector (optional): more effective in preventing motor overheating and enhancing product reliability; 9. Miniaturization design: allowing users to use and install space more effectively; 10. Detachable pipe fittings (optional): easier to install.

5.5kw single impeller high-pressure fan - single-stage high-pressure blowerspecification
Three phase voltage power:0.25KW、0.4KW、0.7KW、0.85KW、1.1KW、1.3KW、1.5KW、1.6KW、2.2KW、3KW、4KW、5.5KW、7.5KW、8.5KW、11KW、12.5KW、15KW、18.5KW、20KW、25KW;Single phase voltage power:0.2KW、0.4KW、0.55K、 0.75KW、0.85KW、1.1KW、1.3KW、2.2KW;Wind pressure:50mbar-1010mbar;Airflow:40m3/h-3000m3/h, For the convenience of selecting different specifications, both single-stage and two-stage models are available in stock;frequency50HZ/60HZ voltage: 110V-615V, suitable for use in all countries. If special voltage is required, it can be customized according to requirements;Pressure relief valve:RV-01 RV-02 (for use with);filter:MF08、MF10、MF12、MF16、MF20、MF32;Silencer interface size:1.25 inches, 1.5 inches, 2 inches, 2.5 inches, 4 inches.
Scope of application
Widely used in environmental treatment equipment such as aeration, aquaculture, biology, agricultural ecological engineering, food, medicine and chemical packaging machinery, cardboard packaging, printing machinery, advertising printing equipment, screen printing machines, photographic plate making machines, plastic rubber machinery and auxiliary equipment, automatic feeding and drying machines, food and beverage filling machines, powder packaging machines, combustion oxygen reduction machines, cigarette filter forming machines, electroplating tank liquid mixing, atomization drying machines, welding equipment, paper transportation, industrial dry cleaning machines, cleaning applications, air dust removal, dry bottles, gas transmission, feeding, collection, environmental water treatment equipment, central dust collection, air treatment equipment, various textile and knitting equipment, cloth, board, leather cutting machinery, industrial cleaning equipment, agricultural product storage, refrigeration engineering. Atomization dryer Industries and fields such as dilute phase gas transportation. Main uses: 1. Water treatment blast aeration, aquaculture aeration, oxygenation, river treatment aeration, etc; 2. Mixing and aeration of sewage in hospitals and laboratories; 3. Vacuum paper feeding in the printing industry. 4. Mixing and aeration of electroplating tanks and industrial wastewater; 5. Gas supply for plastic welding and blowing; 6. Burner spray, glass industry; 7. Aquaculture; 8. Fermentation aeration of materials, organisms, and biochemical tanks; 9. Other equipment that requires a gas source.




advantage
1. By using an AC motor as the drive, the impeller is directly installed on the motor rotor to achieve non-contact compression, ensuring that the vortex air pump can maintain continuous and efficient operation for up to 20000 hours under zero maintenance. 2. By using dual frequency wide voltage technology, the protection level reaches IP55 (insulation level F or H), meeting the needs of different regions for current frequency and voltage. It has the advantages of good frequent starting performance, strong overload capacity, fast automatic protection starting, safety and reliability. 3. Adopting a pre bearing structure, the pump bearings are installed outside the compression chamber to achieve a maximum dynamic balance configuration, enabling arbitrary installation of the product and maintaining long-term continuous balanced operation; This structure has a fast heat dissipation speed, ensuring the reliability of the fan even in high-pressure environments. 4. The whole machine adopts an oil-free device, and the transmission system does not require lubrication. To broaden the application scope of the product, it can be used in medical equipment with strict air quality requirements, precision printing in the printing industry, and integrated circuit manufacturing processes in the electronics industry. At the same time, efficient work does not require other auxiliary equipment and reduces operating costs. 5. The design of the impeller and air duct has been calculated and verified. After optimizing the blade length, air duct curvature, and curvature, compared with similar products, the performance has been improved by more than 30% under the same power input, and the product has lower wind noise, with the whole machine running below 70 decibels. 6. Compared to other types of vacuum pumps, it has the advantages of smooth operation, low noise, and energy saving; Positive and negative pressure, flow rate, efficiency and other indicators meet the standards of Siemens gas ring fans in Germany; The whole machine has a compact structure, light weight, and small volume; High working pressure difference, dual-use for blowing and suction.
Installation instructions and conditions for vortex high-pressure fan
Before installation, it is necessary to familiarize oneself with the various technical requirements in the manual, check whether the accompanying accessories are complete, and whether various technical documents are complete.
2. Conduct a preliminary inspection of the blower to ensure that there are no inorganic parts damaged during logistics transportation or long-term storage, whether there are any debris falling into the fan flow channel, and whether there is corrosion. Then use tools to rotate the fan spindle or the fan motor tail fan blades to see if the rotation is flexible and if there is any rubbing noise. Otherwise, the fault should be eliminated first.
3. According to the foundation diagram, the anchor bolts should be properly positioned. When installing the fan, the horizontal plane should be corrected to prevent excessive tilting.
4. The diameter of the pipeline should be slightly larger than the fan outlet diameter (the ratio of pipeline diameter to fan outlet diameter is 1.1:1), and the length of the pipeline should be shortened as much as possible. Elbows should be used sparingly, and the angle of the elbow should be greater than 90 degrees. It is not allowed to use right angle T-shaped joints. The joints of the pipeline should be tightly sealed and not leak, in order to reduce pressure loss. The weight of the pipeline shall not be supported by the fan, nor shall the fan be forcibly connected to the pipeline to prevent increased vibration and noise.
5. According to the characteristics of the blower, regulating valves can be installed at the inlet or outlet of the blower. Adjustment of air volume and pressure.
To protect the fan motor, a current overload protection device should be installed.
7. Close the air inlet of the fan, try starting the fan, and check if the main shaft rotation of the fan is correct. Then restart the fan and wait for it to operate normally. Gradually open the regulating air door and adjust it to the desired operating point, but the motor current should not exceed the rated value. If the desired operating point happens to be the fan's surge point, the operating point should be adjusted appropriately to avoid the surge point, or other anti surge measures should be taken.