Welcome Customer !

Membership

Help

Shanghai Shengxu Electric Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Shanghai Shengxu Electric Co., Ltd

  • E-mail

  • Phone

  • Address

    Jiangyang South Road, Zhabei District, Shanghai

Contact Now

20KVA/150KV inflatable test transformer

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The 20KVA/150KV inflatable test transformer has the characteristics of small size, light weight, compact structure, complete functions, strong universality, and easy use.

Product Details

20KVA/150KV inflatable test transformerThe high-voltage test transformer is a series of test transformers developed and produced based on the "Test Transformer" standard, which has been greatly improved on the basis of similar products. The high-voltage test transformer is a new type of product developed and produced in accordance with DL/T848.2-2004 "General Technical Conditions for High Voltage Test Devices - Part 2: Power Frequency High Voltage Test Devices". This series of products has the characteristics of small size, light weight, compact structure, complete functions, strong universality, and easy use. High voltage test transformers are particularly suitable for conducting insulation strength tests on various high-voltage electrical equipment, electrical components, and insulation materials under power frequency or DC high voltage in power systems, industrial and mining enterprises, scientific research departments, etc. It is an essential equipment in high-voltage testing.

Environmental requirements:

1. Input voltage: AC 220V or 380V, 50Hz;

2. Environmental temperature: -40 ℃ to 40 ℃;

3. Relative humidity: ≤ 85% (when the ambient temperature is 25 ℃);

4. In an environment without chemical gases and vapors;

5. In non explosive gases;

6. In situations where rainwater does not infiltrate.

20KVA/150KV inflatable test transformerTechnical parameters:

Specification Model Capacity (kVA) High voltage (kV) High voltage current (mA) Low voltage input Variable ratio (high/instrument) Temperature rise ℃ (30 minutes)
Voltage (V) Current (A)
YDJ-3/50 3 50 60 200 15 500 10
YDJ-5/50 5 50 100 200 25 500 10
YDJ-10/50 10 50 200 200 50 500 10
YDJ-20/50 20 50 400 400 50 500 10
YDJ-30/50 30 50 600 400 75 500 10
YDJ-50/50 50 50 1000 400 125 500 10
YDJ-5/100 5 100 50 200 25 1000 10
YDJ-10/100 10 100 100 400 25 1000 10
YDJ-10/25 10 25 400 400 25 1000 10
YDJ-20/100 20 100 200 400 50 1000 10
YDJ-30/100 30 100 300 400 75 1000 10
YDJ-50/100 50 100 500 400 125 1000 10
YDJ-15/150 15 150 100 400 37.5 1000 10
YDJ-20/150 20 150 133 400 50 1000 10