1500XA gas chromatograph

NegotiableUpdate on 09/24
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The 1500XA process gas chromatograph integrates the mature analysis components of on-site gas chromatography with the large capacity constant temperature furnace design of traditional air bath furnaces. The result is to maximize the reliability and flexibility of the analyzer through a single device. Rosemount An

Product Details

The 1500XA process gas chromatograph integrates the mature analysis components of on-site gas chromatography with the large capacity constant temperature furnace design of traditional air bath furnaces. The result is to maximize the reliability and flexibility of the analyzer through a single device.
Rosemount Analytical's 1500XA gas chromatograph is used in various gas processing plants and is specifically designed for trace sulfur, trace hydrocarbons, and other high-temperature applications.
The traditional air bath furnace of 1500XA can use up to 8 gas chromatograph injection valves, with a maximum temperature of 150 ° C for various applications. This chromatograph can provide dual detector applications. The advantages include shorter analysis time and higher sensitivity.
This instrument supports TCD (thermal conductivity detector), FID (hydrogen flame ionization detector), and FPD (flame photometric detector)
The traditional air bath furnace design has the greatest application flexibility
Fully compatible with modern Ethernet and DCS communication
The new XA injection valve is based on an excellent 6-way chromatographic diaphragm valve design.
The constant temperature furnace has a large capacity and can accommodate up to 8 chromatograph injection valves and 2 detectors
You can choose between thermal conductivity detector or hydrogen flame ionization detector
The sensitivity of thermal conductivity detector (TCD) can reach ppm level
Storage capacity of up to 2500 chromatograms, including sampling calibration and calibration flow path
Archive up to 64 average values, up to 35 days of standard operation and calculation
Power Supply:
115 VAC ± 15%,220 VAC ± 15%,50/60 HZ
Operating power of 400 watts, starting power of 1100 watts
Environmental temperature: Thermal conductivity detector (TCD) and hydrogen flame ionization detector (FID) are between 0-55 ° C (32-130 ° F)
Dimensions (excluding sampling system): 198cm high x 61cm wide x 61cm deep (70 inches high x 24 inches wide x 24 inches deep)
Installation method: Wall mounted (standard); Independent installation (optional)
Approximate weight (excluding sampling system): approximately 68 kilograms (150 pounds)
Regional classification options (depending on hardware): Designed to comply with Level 1, Zone I, Groups B, C, and D, with X-shaped blowing; Level 1, Zone 2, Groups B, C, and D, with Z-shaped blowing
Instrument air: 4 standard cubic feet per minute, 40 PSI oil-free instrument air for blowing and constant temperature furnace heating, 90 PSI instrument air for valve actuation
Thermostatic furnace: Air bath furnace, maximum 150 ° C (300 ° F)
Injection valves: 6-way, 10 way XA diaphragm chromatography injection valves (up to 8 injection valves). Other types of valves may be used, depending on the application, such as liquid injection plunger valves and rotary valves
Carrier gas: depends on the application. Usually zero order helium, nitrogen, or hydrogen, with a pressure of 90-120 PSI
Chromatography column: You can choose packed column, micro packed column or capillary column; Depending on the application
Detector: Thermal conductivity detector (TCD), hydrogen flame ionization detector (FID), or flame photometric detector (FPD); The combination of TCD-TCD and TCD-FPD dual detectors is also acceptable
Peak selection: automatic slope sensing with fixed time
Flow path: up to 18 flow paths
Chromatograph control electronic components: integrated installation
Communication (standard):
Ethernet: 2 available connections -1 RJ-45 port, 1 4-wire terminal - speed 10/100 Mbps
Analog input: 2 standard 4-20mA inputs, using transient protection filtering (user expandable and assignable)
Analog input: 6 isolated 4-20mA outputs
Digital switch input: 5, specified by the user, optically isolated, rated at 30VDC @ 0.5A
Digital switch output: 5 user assignable outputs, C-type and electromechanical isolation, 24VDC
Serial interface: 3 wiring ports, configurable as RS-232, RS-422, or RS-485; 1 D-sub (9-pin) port for PC connection
Communication (optional): 2 expansion slots for additional communication. Each slot has a capacity increase of any of the following cards:
4 isolated analog input cards
4 isolated analog output cards
8 digital switch input (isolated) cards
5 digital switch output (isolated) cards
1 RS-232, RS-422 or RS-485 serial interface card
1 modem card, 300-19.2k baud rate