Welcome Customer !

Membership

Help

Shanghai Automation Instrument Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Shanghai Automation Instrument Co., Ltd

  • E-mail

  • Phone

  • Address

    Room 809, Building 1, Instrument Industrial Park, Zhabei District, Shanghai

Contact Now

1151LT4SB0B22DM1D1 flange level transmitter

NegotiableUpdate on 05/14
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The 1151LT4SB0B22DM1D1 flange level transmitter is used to measure micro differential pressure to large differential pressure, low pressure to high pressure, liquid level, vacuum degree, and specific gravity. Combined with the throttling device, flow can also be measured without the need for an external square root opener.

Product Details

1151LT4SB0B22DM1D1 flange level transmitter

Product Overview:

The 1151 transmitter is used to measure micro differential pressure to large differential pressure, low pressure to high pressure, liquid level, vacuum degree, and specific gravity. Combined with the throttling device, flow can also be measured without the need for an external square root opener. Its characteristics are as follows:

High precision, diverse varieties, wide measurement range, and good stability (see variety specification table);

Adopting a two-line working mode;

Using solid circuit components, the printed circuit board has a plug-in method;

Small, sturdy, and highly resistant to vibration;

The range and zero position can be continuously adjusted externally;

Positive migration can reach 500%, negative migration can reach 600%

Adjustable damping;

There are a wide range of options to choose from.

1151LT4SB0B22DM1D1 flange level transmitter

Shanghai Automation Instrument Factory 1151LT4SB0B22DM1D1 flange type liquid level transmitter 0-10KPa0-16KPa0-25KPa 4-20mA DC intelligent electronic component? Structural principle:

The pressure of the measured medium is transmitted to the central measuring diaphragm through the isolation diaphragm of the δ chamber (LT and DP/GP remote transmitters with 1199 are used to transmit the measured pressure first through an isolation diaphragm and a fully sealed capillary system filled with silicone oil or fluorine oil before being transmitted to the isolation diaphragm of the δ chamber) and the filling oil in it. Except for the AP type pressure transmitter, which measures the vacuum reference point on the other side of the diaphragm, other types of measuring diaphragms have either atmospheric pressure or the low-pressure side of the measured differential pressure. The measuring diaphragm is a pre tensioned elastic element, and its displacement is proportional to the pressure of the measured medium. The largest displacement is only 0.10mm, and the position of the measuring diaphragm is detected by the capacitor fixed plates on both sides. The differential capacitance between the measuring membrane and the fixed plates of the two capacitors is linearly converted into a two-wire current signal of 4-20mADC by the amplification circuit.

0-10KPa0-16KPa0-25KPa 4-20mA DC intelligent electronic components? Main technical indicators:

Target audience: liquids, gases, or vapors

Measurement range attack: see variety specification table

Output signal: DC 4-20Ma

L-type low power consumption (hereinafter referred to as L-type) is DC0.8-3.2V;

M-type low-power (hereinafter referred to as M-type) is DC1-5V;

Power supply: The typical power supply voltage is DC24V. When the transmitter is not loaded, the working power supply can be DC 5-12V;

The working voltage range of L-type is DC5-12V

The working voltage range of M-type is DC8-12V

Is the load impedance of L and M types 10K?

Indicator header: The size of the on-site indicator gauge is 50.8mm, with an indication accuracy of plus or minus 2%

Power consumption: only applicable to L and M models. Under normal working conditions, the L-type is 1.5mA and the M-type is 2.0Ma.

Variety specifications:

Variety model name

measurement range

precision

stability

1151DP low, medium, and high differential pressure transmitter (461/293)

0-1.24-186.45KPA

+-0.2%

<+-0.2%/6 months

1151DP large differential pressure transmitter (461/293)

0-117.21KPA-6.89MPA

+-0.25%

<+-25%/6 months

1151HP high static pressure differential pressure transmitter (461/294)

0-6.22KPA-2.07MPA

+-0.25%

<+-25%/6 months

1151DP flow transmitter (461/294)

0-1.24KPA-2.07MPA

+-0.25%

<+-25%/6 months

1151GP pressure transmitter (461/295)

0-1.24KPA-186.45KPA

+-0.25%

<+-25%/6 months

1151GP/DP remote differential pressure transmitter 461/300)

0-1.24KPA-41.37MPA

+-0.25%

<+-25%/6 months

1151AP pressure transmitter (461/295)

0-5.22KPA-6.89MPA

+-0.25%

<+-25%/6 months

1151LT flange type liquid level transmitter (461/297)

0-6.77KPA-6.89MPA

+-0.25%

<+-25%/6 months

1151DR Micro Differential Pressure Transmitter (461/297)

0-6.22KPA-689.48MPA

+-0.25%

<+-25%/6 months

1151DP low-power transmitter

0-0.12-1.49KPA

+-0.50%

<+-50%/6 months

Note: Flange type liquid level transmitter, with flat flange and plug-in flange; There are four combinations available for users to choose from when installing flanges: 3 #, 4 150 # (working pressure of 1.89MPa), and t 300 # (working pressure of 4.95MPa). In addition to 316 stainless steel, there are also Hastelloy, Monel, and Tantalum materials that can be used in corrosive media.

After the 1151DP/GP pressure/differential pressure transmitter is equipped with the 1199 remote transmission sealing device, it can avoid direct contact between the measured medium and the isolation diaphragm of the transmitter, providing a reliable measurement.

115LT type

Flange mounted liquid level transmitter



measurement range

4

5

6

0-6.22 KPa~0-37.29kPa

0-31.1kPa to 0-186.6kPa

0-117.1KPa~0-688.62kPa


code name

Output

E

4-20mA DC damping adjustable


4~20mA DC, Intelligent electronic components


code name

size

Insertion tube length

High voltage side isolation diaphragm and insertion tube material

A0

A2

A4

A6

B0

B2

B4

B6

C0

C2

C4

C6

D0

D2

D4

D6

E0

F0

3#

3#

3#

3#

4#

4#

4#

4#

3#

3#

3#

3#

4#

4#

4#

4#

3#

4#

flat

50.8mm

101.6mm

152.4mm

flat

50.8mm

101.6mm

152.4mm

flat

50.8mm

101.6mm

152.4mm

flat

50.8mm

101.6mm

152.4mm

flat

flat

316SST stainless steel

316SST stainless steel

316SST stainless steel

316SST stainless steel

316SST stainless steel

316SST stainless steel

316SST stainless steel

316SST stainless steel

Hastelloy C

Hastelloy C

Hastelloy C

Hastelloy C

Hastelloy C

Hastelloy CHastelloy C

Hastelloy C

Tantalum

Tantalum


code name

Install flange

A

C

D

(3 inches, 150 pounds) used in conjunction with codes A and C above, carbon steel

(4 inches, 150 pounds) used in conjunction with codes B and D above, carbon steel

(3 inches, 150 pounds) used in conjunction with codes A and C above, carbon steel

(4 inches, 150 pounds) used in conjunction with codes B and D above, carbon steel


code name

Structural materials for sensor components and low-voltage side

Low pressure side pressure chamber and joint

relief valve

Low voltage side isolation membrane

Low pressure side filling fluid

12

55

22

23

25

33

35

Plated carbon steel

Plated carbon steel

316SST stainless steel

316SST stainless steel

316SST stainless steel

Hastelloy C

Hastelloy C

316SST stainless steel

316SST stainless steel

316SST stainless steel

316SST stainless steel

316SST stainless steel

Hastelloy C

Hastelloy C

316SST stainless steel

Tantalum

316SST stainless steel

Hastelloy C

Tantalum

Hastelloy C

Tantalum

silicone oil

1A

5D

2A

2B

2D

3B

3D

Plated carbon steel

Plated carbon steel

316SST stainless steel

316SST stainless steel

316SST stainless steel

Hastelloy C

Hastelloy C

316SST stainless steel

316SST stainless steel

316SST stainless steel

316SST stainless steel

316SST stainless steel

Hastelloy C

Hastelloy C

316SST stainless steel

Tantalum

316SST stainless steel

Hastelloy C

Tantalum

Hastelloy C

Tantalum

Inert oil


code name

High pressure side liquid flange filling fluid

D

F

G

silicone oil

fluorinated oil

Glycerol and water

Noobee M-20

Syltherm 800


code name

Optional items

M1

M3

M5

Linear header, 0 to scale

Linear header, special scale

Copper O-type diagram, used for 6.9-41.45KPa

Work pressure (pressure) 0.5~6Psia

1151LT 4 E AO A 23 D M1 transmitter complete model