100 ℃ automatic dew removal temperature and humidity sensor

NegotiableUpdate on 05/01
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

100 ℃ automatic dew removal temperature and humidity sensor

Product Details

Automatic dew removal type high temperature and high humidity sensor


Suitable for lead-acid acidBattery plate solidification chamber,temperature0 to 100 ℃/humidity3-99.9%

1、 Overview
Our company's resistive humidity sensor has excellent temperature and humidity resistance, and can measure temperature and humidity in the process environment within the high temperature range of 0-150 ℃ and 3-99.9% high humidity range. High precision and superior repeatability ensure long-term stability and service life. It is the most cost-effective product in this field.
This product is a two-piece wall mounted form, and the temperature and humidity probe and transmitter can be connected by remote wiring.
The temperature and humidity probe can be directly placed in the environment being measured - the battery plate curing room
The temperature and humidity transmitter can be placed 1-20 meters away from the measured environmental location (such as near a distribution cabinet or temperature and humidity control instrument)
The designed automatic dew removal probe, with a built-in dew removal fan, is suitable for long-term use in environments with high or low temperatures, easy frosting or condensation.
In high humidity environments, if there is condensation, the dew removal process will automatically start, and the measurement will automatically stop during the dew removal process. The built-in delayed start function effectively prevents misoperation caused by humidity overshoot caused by immediate humidification when the humidity drops below the set humidity during the dew removal process.
It is suitable for various special environments: high and low temperatures, high and low humidity, pollution, dust, flammable, explosive and other environments. This product only requires placing the temperature and humidity probe into the tested environment.
This product is widely used for process measurement and control in industries such as dryers, drying kilns, meteorology, environmental protection, cement maintenance, wood, pharmaceuticals, textiles, chemicals, steel, non-ferrous metal smelting, food, battery electrode solidification rooms, controlled atmosphere warehouses, and cold storage.
This product is equipped with various temperature and humidity measurement and control instruments from our company, such as single-stage temperature and humidity control instruments, intelligent 32 stage temperature and humidity control instruments, and touch screen 50 stage temperature and humidity control instruments. It can be connected to heaters, cooling machines, humidifiers, and dehumidifiers to achieve fully automatic constant temperature and humidity control for the tested environment


II Automatic dew removal type high temperature and high humidity sensorTechnical Parameter
Power supply: DC 24V DC 12V
Range: Humidity: 0-100% RH
Temperature: 0-100 ℃ (other ranges are optional)
Working environment temperature: -10-60 ℃ (transmitter)
Temperature accuracy: ± 0.5 ℃ (0-150 ℃)
Humidity accuracy: ± 3% RH ± 5% RH (15% -95% RH, 25 ℃)
Response time: ≤ 2s
Output signal: Voltage type: 0-10V; 0-5V(Three wire system)
Current type: 4-20mA (three wire system, two wire system)
Load capacity: Current type ≤ 600 Ω
Voltage type ≥ 2K Ω
Shell: ABS white 100mm × 68mm × 50mm

III Automatic dew removal type high temperature and high humidity sensorAppearance and wiring
Wiring instructions: (Any incorrect wiring may cause irreversible damage to the transmitter)

See Figure 1 below

Red line 24V+: power supply+

Black line 24-: Power supply-GND (between 24 and RH, this terminal is available for the three wire system)

Yellow line RT: Temperature+

Blue line RH: humidity+


In the legendABTo display instruments, actuators, or acquisition cards,ACorresponding temperature output of the circuit,BThe road corresponds to humidity output.

Current output type: Three-wire

See Figure 2 below


Current output type: two-wire systemVoltage output type three wire system



4Automatic dew removal type high temperature and high humidity sensorpeacefuldress

See Figure 4 below


Installation steps:

1Transmitter section: The bottom of the transmitter has4Install holes and secure them to the wall using standard expansion screws and screws.

2Probe usedM27*2The installation thread or outer diameter is68mmThe plastic or cast aluminum movable flange is fixed on the wall or pipeline (optional thread or flange)

3Connect the transmitter cable to the acquisition device

Installation position

1The transmitter should be placed vertically as much as possible, and during installation, ensure that the sensor is on top of it

The font should be in the positive direction to ensure that the sensor is located below the transmitter;

2The installation height is the height of the human body sitting or the main environmental area that requires measurement

Installation precautions

1Avoid generating temperature in areas that are easy to transfer heat and directly affect the test area

Installation in poor areas may result in inaccurate temperature and humidity measurements.

2Install in a stable environment area. Avoid direct sunlight, stay away from windows, air conditioning, heating and other equipment, and avoid facing windows or doors directly.

3Try to stay away from high-power interference equipment as much as possible to avoid inaccurate measurements, such as frequency converters, motors, etc.


5 Automatic dew removal type high temperature and high humidity sensoruse

1Carefully check and ensure that the wiring is correct before connecting itDC24VWhen measuring the power supply with a multimeter, the corresponding current or voltage will be measuredValue.

2If you want to disassemble the transmitter, you must first disconnect the power supply and then proceed with the disassembly.

3This transmitter is an indoor type, and water should be avoided from entering the inside of the transmitter to prevent damage.

4In the form of a wall mounted two-piece set, the connection between the temperature and humidity probe and the transmitter exceeds30riceA double stranded connection should be used.

The two humidity lines cannot be in the same protective tube.

Use a two-piece set of temperature and humidity sensors, with the transmitter placed at room temperature and humidityIn the environment, simply use the temperature and humidity probe (sensor)

Place it in the location being tested.Transmitter andTemperature and humidity probe (sensor) connectionUse high-temperature flame-retardant sheathed wire.

6、 Precautions

1Please read this manual carefully before use to ensure correct wiring. appointAny incorrect wiring may cause irreversible damage to the transmitter.

2Avoid generating temperature in areas that are easy to transfer heat and directly affect the test areaInstallation in poor areas may result in inaccurate temperature and humidity measurements.

Prevent direct damage to the sensor from chemical reagents, oil, dust, etc. Do not use it for a long time in environments with condensation or extreme temperatures.

Do not perform cold or hot shocks.


maintenance

Long term use of the transmitter may cause drift. To ensure measurement accuracy,*Okay, calibrate once a year.


Transportation and storage

1Try to avoid vibration and handle the transmitter gently.

2Long term storage conditions:104020%RH80%RH.


9、 Open box inspection

1. After opening the packaging, check if the transmitter is intact.

2. One transmitter, one instruction manual, and one certificate of conformity.


10、 Fault analysis and troubleshooting

1. When simulating output, if the transmitter output is 0 or the output value is not within the range, please check if the wiring is correct,

Or whether it is firm.

2. If it is not for the above reasons, please contact the manufacturer.