0139 Vibrio cholerae detection kit (colloidal gold method)

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The 0139 Vibrio cholerae detection kit (colloidal gold method) is developed using monoclonal antibody colloidal gold labeling technology and membrane chromatography technology, and is used for qualitative detection of specific antigens A and O139 of Vibrio cholerae O1 that may be present in samples.

Product Details

0139 Vibrio cholerae detection kit (colloidal gold method)


Common name: O139 Vibrio cholerae detection kit (colloidal gold method)
English name: Rapid Test for Vibrato Cholera O139
[Specification]
1 person per bag, 10 person per box

Cholera is an acute intestinal infectious disease caused by Vibrio cholerae group 01 or 0139. It is one of the quarantine infectious diseases characterized by rapid onset, fast transmission, wide spread, and the ability to cause large-scale outbreaks. It is also classified as a Class A infectious disease under the Infectious Disease Prevention and Control Law of the People's Republic of China. This product is developed using monoclonal antibody colloidal gold labeling technology and membrane chromatography technology. It is used for qualitative detection of specific antigens of Vibrio cholerae 01 that may exist in samples, and is suitable for emergency detection in disease control systems and hospital diarrhea clinics, thereby achieving rapid screening of cholera cases.

Good specificity: No cross reactivity with 15 common intestinal bacteria. It can be used before and after bacterial growth.
High sensitivity: Vibrio cholerae with a low detection level of no less than 105 Bacteria per milliliter, consistent with confirmed cholera cases of 106Bacteria per milliliter or more. 10 minutes for results, greatly reducing patient waiting time for testing.
Integration convenience: The detection device is designed with a "plug-in" design, with the serial number ZL03267199.7, and each person is equipped with a sampling device.
Widely used: clinical diarrhea clinics, emergency departments; Grassroots community hospitals and township health centers; The disease control system is used for on-site screening of outbreaks.

Storage conditions and expiration date
1. Storage conditions: Store at room temperature and away from light
2. Validity period: 18 months

1. Be sure to mix the sample to be tested with diluent before testing.
2. Store in a greenhouse away from light.
National Standards and Honors
1. This testing method has been included in the cholera diagnostic standard WS289-2008 of the "Industry Standards of the Ministry of Health of the People's Republic of China".
2. This testing method has been included in the "Catalogue of Clinical Laboratory Items in Medical Institutions".
3. Won the "National Key New Product Certificate" jointly issued by four ministries and commissions including the national government.
4. Received the "Certificate of Independent Innovation Product" issued by Beijing Municipality.
0139 Vibrio cholerae detection kit (colloidal gold method)