Thermo Fisher TG MaxMS GC capillary gas chromatography column

NegotiableUpdate on 05/13
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Thermophile TG WaxMS GC capillary gas chromatographic column $r $n (article number 26088-1420) is a high-performance chromatographic column specially designed for the analysis of polar compounds. It is widely used in the fields of pharmacy, food, environment and other fields for the high-resolution separation of alcohols, organic acids, sugars and essence. ‌

Product Details

Thermo FisherTG-WaxMS GCCapillary gas chromatography column

(Item number)26088-1420)It is a high-performance chromatographic column specially designed for the analysis of polar compounds. It is widely used in the high resolution separation of alcohols, organic acids, sugars and essence in pharmaceutical, food, environmental and other fields‌.‌

‌Product Name‌:TraceGOLD™ TG-WaxMS GCCapillary chromatography column

Item No.‌26088-1420‌

Brand: Thermo Fisher ScientificThermo ‌

Measurement object: Separation of cations

Size:0.25*30mmcm

Column type: protective column‌

‌stationary phase‌Polyethylene glycol(PEG,Carbowax™Similar in appearance)

‌length‌:30 m

‌inner diameter‌:0.25 mm

‌film thickness‌:0.25 μm

‌temperature range‌:‌240°C(Constant temperature)/ 260°C(Program heating up)‌It is recommended to use it for a long time without exceeding240°C

‌USPclassification‌:G4TheG14TheG15TheG16TheG20TheG39

‌polarity‌:‌polarity‌

‌Applicable detector‌:FIDTheTCDTheECDThe‌GC/MS‌

‌product line‌:TraceGOLD ™

‌Place of Origin‌: United States

Typical application areas‌

This chromatographic column is particularly suitable for the following analytical scenarios:

‌pharmaceutical industry‌Based on:USP <467>Testing of active pharmaceutical ingredients and excipients‌residual solvent‌(such as ethanol, isopropanol, ethyl acetate)

‌Food and spices‌: Analysis‌Fatty acid methyl ester(FAME)‌、‌flavor compounds‌、‌Essence oil‌、‌Alcohols and organic acids‌

‌Environmental Monitoring‌: Separation‌Xylene isomer‌、‌Solvent mixture‌

‌Forensic Medicine and Chemical Engineering‌Used for substances such as acrylonitrileEPA Method 603 GC/MSanalyze

Key performance advantages‌

‌high thermal stability‌Adopting strengthened bonding technology significantly improves column life and high temperature tolerance, reducing baseline drift

‌Low loss characteristics‌Suitable for high-sensitivity mass spectrometry detection(GC/MS)Effectively reduce background noise

‌Excellent inter column reproducibility‌Each column undergoes strict factory testing and comes with‌COAQuality Certificate‌Support method validation and compliance declaration

‌High corrosion resistance‌Strong resistance to oxidative and acidic/alkaline samples, superior to traditional silicon-based stationary phases

Instructions for Use and Maintenance‌

‌Installation direction‌:Strictly follow the gas flow direction indicated on the chromatographic column(→)Installation, connect the injection port end to the injection spacer, and connect the detector endFIDorMSIonic source.

‌Aging treatment (mandatory)‌:New or unused columns need to undergo programmed temperature aging to remove residual solvents and volatiles:

1.Initial temperature:50°CMaintain it2 min

2.Heating rate:10°C/min

3.Termination temperature:‌250°C‌Maintain it‌30–60 min‌

4.Carrier gas:‌Helium or nitrogen, flow rate1.0 mL/min ‌Ensure that there is a carrier gas passing through the entire process

‌Avoid pollution‌:

1.The sample needs to undergo ‌0.22 μmmembrane filtration‌To avoid particle blockage

2.High boiling point, strong acid, strong base or non-volatile substances need to pass through‌Solid phase extraction(SPE)Or liquid-liquid extraction‌Pre processing removal

‌Column head cutting and regeneration‌:If there is peak tailing, retention time drift, or column pressure increase, it can be cut off from the injection port end ‌10–20 cm‌Use after re aging

‌storage method‌:After use, seal both ends with sealing caps,‌Store in a dry and cool place‌Avoid direct sunlight or severe vibrations